{"id":"https://openalex.org/W3096952829","doi":"https://doi.org/10.1002/2050-7038.12686","title":"A new dual\u2010input three\u2010winding coupled\u2010inductor based DC\u2010DC boost converter for renewable energy applications","display_name":"A new dual\u2010input three\u2010winding coupled\u2010inductor based DC\u2010DC boost converter for renewable energy applications","publication_year":2020,"publication_date":"2020-11-02","ids":{"openalex":"https://openalex.org/W3096952829","doi":"https://doi.org/10.1002/2050-7038.12686","mag":"3096952829"},"language":"en","primary_location":{"id":"doi:10.1002/2050-7038.12686","doi":"https://doi.org/10.1002/2050-7038.12686","is_oa":false,"landing_page_url":"https://doi.org/10.1002/2050-7038.12686","pdf_url":null,"source":{"id":"https://openalex.org/S2500072609","display_name":"International Transactions on Electrical Energy Systems","issn_l":"2050-7038","issn":["2050-7038"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Transactions on Electrical Energy Systems","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5040644745","display_name":"Saeed Danyali","orcid":"https://orcid.org/0000-0003-2873-6469","observed_orcids":["https://orcid.org/0000-0003-2873-6469"]},"institutions":[{"id":"https://openalex.org/I4210116604","display_name":"Ilam University","ror":"https://ror.org/01r277z15","country_code":"IR","type":"education","lineage":["https://openalex.org/I4210116604"]}],"countries":["IR"],"is_corresponding":true,"raw_author_name":"Saeed Danyali","raw_affiliation_strings":["Faculty of Engineering Ilam University  Ilam Iran"],"raw_orcid":"https://orcid.org/0000-0003-2873-6469","affiliations":[{"raw_affiliation_string":"Faculty of Engineering Ilam University  Ilam Iran","institution_ids":["https://openalex.org/I4210116604"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5002828681","display_name":"Rahmat Aazami","orcid":"https://orcid.org/0000-0002-1585-029X","observed_orcids":["https://orcid.org/0000-0002-1585-029X"]},"institutions":[{"id":"https://openalex.org/I4210116604","display_name":"Ilam University","ror":"https://ror.org/01r277z15","country_code":"IR","type":"education","lineage":["https://openalex.org/I4210116604"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Rahmat Aazami","raw_affiliation_strings":["Faculty of Engineering Ilam University  Ilam Iran"],"raw_orcid":"https://orcid.org/0000-0002-1585-029X","affiliations":[{"raw_affiliation_string":"Faculty of Engineering Ilam University  Ilam Iran","institution_ids":["https://openalex.org/I4210116604"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047753322","display_name":"Amin Moradkhani","orcid":"https://orcid.org/0000-0002-4535-1950","observed_orcids":["https://orcid.org/0000-0002-4535-1950"]},"institutions":[{"id":"https://openalex.org/I4210116604","display_name":"Ilam University","ror":"https://ror.org/01r277z15","country_code":"IR","type":"education","lineage":["https://openalex.org/I4210116604"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Amin Moradkhani","raw_affiliation_strings":["Faculty of Engineering Ilam University  Ilam Iran"],"raw_orcid":"https://orcid.org/0000-0002-4535-1950","affiliations":[{"raw_affiliation_string":"Faculty of Engineering Ilam University  Ilam Iran","institution_ids":["https://openalex.org/I4210116604"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5044709207","display_name":"Mostafa Haghi","orcid":"https://orcid.org/0000-0001-8966-0176","observed_orcids":["https://orcid.org/0000-0001-8966-0176"]},"institutions":[{"id":"https://openalex.org/I34809795","display_name":"Medizinische Hochschule Hannover","ror":"https://ror.org/00f2yqf98","country_code":"DE","type":"education","lineage":["https://openalex.org/I34809795"]},{"id":"https://openalex.org/I94509681","display_name":"Technische Universit\u00e4t Braunschweig","ror":"https://ror.org/010nsgg66","country_code":"DE","type":"education","lineage":["https://openalex.org/I94509681"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Mostafa Haghi","raw_affiliation_strings":["Peter L. Reichertz Institute for Medical Informatics of TU Braunschweig and Hannover Medical School Braunschweig  Braunschweig Germany"],"raw_orcid":"https://orcid.org/0000-0001-8966-0176","affiliations":[{"raw_affiliation_string":"Peter L. Reichertz Institute for Medical Informatics of TU Braunschweig and Hannover Medical School Braunschweig  Braunschweig Germany","institution_ids":["https://openalex.org/I34809795","https://openalex.org/I94509681"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5040644745"],"corresponding_institution_ids":["https://openalex.org/I4210116604"],"apc_list":{"value":3000,"currency":"USD","value_usd":3000},"apc_paid":null,"fwci":0.7745,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.66992798,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":97},"biblio":{"volume":"31","issue":"1","first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/boost-converter","display_name":"boost converter","score":0.8840000033378601},{"id":"https://openalex.org/keywords/coupled-inductor","display_name":"coupled inductor","score":0.7919999957084656},{"id":"https://openalex.org/keywords/dual-input-converter","display_name":"dual-input converter","score":0.9660000205039978},{"id":"https://openalex.org/keywords/non-isolated-converter","display_name":"non-isolated converter","score":0.9369999766349792},{"id":"https://openalex.org/keywords/maximum-power-point-tracking","display_name":"maximum power point tracking","score":0.8489999771118164},{"id":"https://openalex.org/keywords/renewable-energy-harvesting","display_name":"renewable energy harvesting","score":0.890999972820282},{"id":"https://openalex.org/keywords/battery-energy-storage","display_name":"battery energy storage","score":0.6959999799728394},{"id":"https://openalex.org/keywords/bidirectional-power-flow","display_name":"bidirectional power flow","score":0.9509999752044678},{"id":"https://openalex.org/keywords/high-voltage-gain","display_name":"high voltage gain","score":0.890999972820282},{"id":"https://openalex.org/keywords/power-efficiency","display_name":"power efficiency","score":0.5690000057220459}],"concepts":[{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.684548020362854},{"id":"https://openalex.org/C144534570","wikidata":"https://www.wikidata.org/wiki/Q5325","display_name":"Inductor","level":3,"score":0.6576734781265259},{"id":"https://openalex.org/C2780980858","wikidata":"https://www.wikidata.org/wiki/Q110022","display_name":"Dual (grammatical number)","level":2,"score":0.5192949175834656},{"id":"https://openalex.org/C103303742","wikidata":"https://www.wikidata.org/wiki/Q1293595","display_name":"Flyback converter","level":4,"score":0.49782347679138184},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4435759484767914},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4319431185722351},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.39636749029159546},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.32008758187294006},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.14746582508087158},{"id":"https://openalex.org/C142362112","wikidata":"https://www.wikidata.org/wiki/Q735","display_name":"Art","level":0,"score":0.0},{"id":"https://openalex.org/C124952713","wikidata":"https://www.wikidata.org/wiki/Q8242","display_name":"Literature","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1002/2050-7038.12686","doi":"https://doi.org/10.1002/2050-7038.12686","is_oa":false,"landing_page_url":"https://doi.org/10.1002/2050-7038.12686","pdf_url":null,"source":{"id":"https://openalex.org/S2500072609","display_name":"International Transactions on Electrical Energy Systems","issn_l":"2050-7038","issn":["2050-7038"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Transactions on Electrical Energy Systems","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":1.0},{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":30,"referenced_works":["https://openalex.org/W1492840649","https://openalex.org/W1676222619","https://openalex.org/W1969798305","https://openalex.org/W1988860725","https://openalex.org/W1997998778","https://openalex.org/W2007977449","https://openalex.org/W2036019765","https://openalex.org/W2050091081","https://openalex.org/W2059219910","https://openalex.org/W2064336853","https://openalex.org/W2067887469","https://openalex.org/W2074795077","https://openalex.org/W2099211093","https://openalex.org/W2124601677","https://openalex.org/W2138584170","https://openalex.org/W2153155243","https://openalex.org/W2165923809","https://openalex.org/W2178075805","https://openalex.org/W2267945931","https://openalex.org/W2343366902","https://openalex.org/W2428194973","https://openalex.org/W2617701078","https://openalex.org/W2762556120","https://openalex.org/W2889462758","https://openalex.org/W2899223939","https://openalex.org/W2909429553","https://openalex.org/W2943683716","https://openalex.org/W2950952039","https://openalex.org/W2963415148","https://openalex.org/W3022422816"],"related_works":["https://openalex.org/W2901018591","https://openalex.org/W4378070207","https://openalex.org/W4313319643","https://openalex.org/W2921946305","https://openalex.org/W4403318982","https://openalex.org/W3016237223","https://openalex.org/W7139019843","https://openalex.org/W4385702719","https://openalex.org/W4376478072","https://openalex.org/W2026907078"],"abstract_inverted_index":{"Background":[0],"A":[1,79],"new":[2],"non-isolated":[3],"high":[4,149],"voltage":[5,69,150],"dual-input":[6],"three":[7],"coupled-inductor":[8,35],"based":[9],"dc-dc":[10],"boost":[11],"converter":[12,59,67,85,101,120,127],"for":[13,74],"harvesting":[14],"energy":[15],"from":[16,129],"a":[17,42,45],"renewable":[18,46,76],"source":[19],"and":[20,36,48,70,88,104,112,115,131,139,152],"an":[21],"storage":[22],"element":[23],"is":[24],"proposed":[25,84,119,126],"here.":[26],"Methods":[27],"It":[28],"employs":[29],"only":[30],"one":[31],"integrated":[32],"three-winding":[33],"magnetic":[34,140],"two":[37,53],"power":[38,60,137,143,154],"switches":[39,61,138],"to":[40,64,107],"interface":[41],"battery":[43,147],"source,":[44],"resource":[47],"the":[49,58,66,75,83,97,100,108,113,118,146],"output":[50,68],"load.":[51],"The":[52,125],"PWM":[54],"switching":[55],"signals":[56],"of":[57,82,99,117,136],"are":[62,122],"utilized":[63],"regulate":[65],"realize":[71],"MPPT":[72],"performance":[73,121],"source.":[77],"Results":[78],"laboratory":[80],"prototype":[81],"was":[86],"built":[87],"experimented":[89],"in":[90,102],"different":[91],"operation":[92],"conditions.":[93],"Based":[94],"on":[95],"this,":[96],"capability":[98],"accurate":[103],"fast":[105],"responding":[106],"applied":[109],"step":[110],"changes":[111],"effectiveness":[114],"validity":[116],"recognized.":[123],"Conclusion":[124],"benefits":[128],"simple":[130],"compact":[132],"structure,":[133],"minimum":[134],"number":[135],"elements,":[141],"bidirectional":[142],"flow":[144],"at":[145],"port,":[148],"gain":[151],"acceptable":[153],"efficiency.":[155]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":3}],"updated_date":"2026-11-13T13:42:25.865203","created_date":"2020-11-09T00:00:00"}
