{"id":"https://openalex.org/W3091998196","doi":"https://doi.org/10.1016/j.nucengdes.2020.110800","title":"Stochastic finite elements analysis of large concrete structures\u2019 serviceability under thermo-hydro-mechanical loads \u2013 Case of nuclear containment buildings","display_name":"Stochastic finite elements analysis of large concrete structures\u2019 serviceability under thermo-hydro-mechanical loads \u2013 Case of nuclear containment buildings","publication_year":2020,"publication_date":"2020-10-10","ids":{"openalex":"https://openalex.org/W3091998196","doi":"https://doi.org/10.1016/j.nucengdes.2020.110800","mag":"3091998196"},"language":"en","primary_location":{"id":"doi:10.1016/j.nucengdes.2020.110800","doi":"https://doi.org/10.1016/j.nucengdes.2020.110800","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.nucengdes.2020.110800","pdf_url":"https://www.sciencedirect.com/science/article/pii/S0029549320302946","source":{"id":"https://openalex.org/S102681701","display_name":"Nuclear Engineering and Design","issn_l":"0029-5493","issn":["0029-5493","1872-759X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-d","jufo-3","norway-1","poland-100","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"Nuclear Engineering and Design","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://www.sciencedirect.com/science/article/pii/S0029549320302946","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5041968070","display_name":"David Bouhjiti","orcid":"https://orcid.org/0000-0001-6357-5205","observed_orcids":["https://orcid.org/0000-0001-6357-5205"]},"institutions":[{"id":"https://openalex.org/I106785703","display_name":"Institut polytechnique de Grenoble","ror":"https://ror.org/05sbt2524","country_code":"FR","type":"education","lineage":["https://openalex.org/I106785703","https://openalex.org/I899635006"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210143269","display_name":"Sols, Solides, Structures, Risques","ror":"https://ror.org/03bcdsr62","country_code":"FR","type":"facility","lineage":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I4210095849","https://openalex.org/I4210143269","https://openalex.org/I899635006"]},{"id":"https://openalex.org/I899635006","display_name":"Universit\u00e9 Grenoble Alpes","ror":"https://ror.org/02rx3b187","country_code":"FR","type":"education","lineage":["https://openalex.org/I899635006"]}],"countries":["FR"],"is_corresponding":true,"raw_author_name":"D.E.-M. Bouhjiti","raw_affiliation_strings":["Grenoble INP Partnership Foundation \u2013 Industrial chair PERENITI, Grenoble, France","Institute of Engineering, Univ. Grenoble Alpes, France","Univ. Grenoble Alpes, CNRS, Grenoble INP, 3SR, F-38000 Grenoble, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Grenoble INP Partnership Foundation \u2013 Industrial chair PERENITI, Grenoble, France","institution_ids":["https://openalex.org/I106785703"]},{"raw_affiliation_string":"Institute of Engineering, Univ. Grenoble Alpes, France","institution_ids":["https://openalex.org/I899635006"]},{"raw_affiliation_string":"Univ. Grenoble Alpes, CNRS, Grenoble INP, 3SR, F-38000 Grenoble, France","institution_ids":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I4210143269"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081192545","display_name":"Julien Baroth","orcid":"https://orcid.org/0000-0001-5261-9284","observed_orcids":["https://orcid.org/0000-0001-5261-9284"]},"institutions":[{"id":"https://openalex.org/I106785703","display_name":"Institut polytechnique de Grenoble","ror":"https://ror.org/05sbt2524","country_code":"FR","type":"education","lineage":["https://openalex.org/I106785703","https://openalex.org/I899635006"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210143269","display_name":"Sols, Solides, Structures, Risques","ror":"https://ror.org/03bcdsr62","country_code":"FR","type":"facility","lineage":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I4210095849","https://openalex.org/I4210143269","https://openalex.org/I899635006"]},{"id":"https://openalex.org/I899635006","display_name":"Universit\u00e9 Grenoble Alpes","ror":"https://ror.org/02rx3b187","country_code":"FR","type":"education","lineage":["https://openalex.org/I899635006"]}],"countries":["FR"],"is_corresponding":true,"raw_author_name":"J. Baroth","raw_affiliation_strings":["Institute of Engineering, Univ. Grenoble Alpes, France","Univ. Grenoble Alpes, CNRS, Grenoble INP, 3SR, F-38000 Grenoble, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Engineering, Univ. Grenoble Alpes, France","institution_ids":["https://openalex.org/I899635006"]},{"raw_affiliation_string":"Univ. Grenoble Alpes, CNRS, Grenoble INP, 3SR, F-38000 Grenoble, France","institution_ids":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I4210143269"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5083213123","display_name":"Fr\u00e9d\u00e9ric Dufour","orcid":"https://orcid.org/0000-0002-2086-4530","observed_orcids":["https://orcid.org/0000-0002-2086-4530"]},"institutions":[{"id":"https://openalex.org/I106785703","display_name":"Institut polytechnique de Grenoble","ror":"https://ror.org/05sbt2524","country_code":"FR","type":"education","lineage":["https://openalex.org/I106785703","https://openalex.org/I899635006"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210143269","display_name":"Sols, Solides, Structures, Risques","ror":"https://ror.org/03bcdsr62","country_code":"FR","type":"facility","lineage":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I4210095849","https://openalex.org/I4210143269","https://openalex.org/I899635006"]},{"id":"https://openalex.org/I899635006","display_name":"Universit\u00e9 Grenoble Alpes","ror":"https://ror.org/02rx3b187","country_code":"FR","type":"education","lineage":["https://openalex.org/I899635006"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"F. Dufour","raw_affiliation_strings":["Institute of Engineering, Univ. Grenoble Alpes, France","PERENITI chairholder (EDF SEPTEN/DTG/CIH), France","Univ. Grenoble Alpes, CNRS, Grenoble INP, 3SR, F-38000 Grenoble, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Engineering, Univ. Grenoble Alpes, France","institution_ids":["https://openalex.org/I899635006"]},{"raw_affiliation_string":"PERENITI chairholder (EDF SEPTEN/DTG/CIH), France","institution_ids":[]},{"raw_affiliation_string":"Univ. Grenoble Alpes, CNRS, Grenoble INP, 3SR, F-38000 Grenoble, France","institution_ids":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I4210143269"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019043171","display_name":"Sylvie Michel-Ponnelle","orcid":"https://orcid.org/0000-0003-4138-5843","observed_orcids":["https://orcid.org/0000-0003-4138-5843"]},"institutions":[{"id":"https://openalex.org/I4210143116","display_name":"\u00c9lectricit\u00e9 de France (France)","ror":"https://ror.org/03wb8xz10","country_code":"FR","type":"company","lineage":["https://openalex.org/I4210143116"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"S. Michel-Ponnelle","raw_affiliation_strings":["Electricit\u00e9 De France (EDF-R&D), Paris, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electricit\u00e9 De France (EDF-R&D), Paris, France","institution_ids":["https://openalex.org/I4210143116"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5019801315","display_name":"Beno\u00eet Masson","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210143116","display_name":"\u00c9lectricit\u00e9 de France (France)","ror":"https://ror.org/03wb8xz10","country_code":"FR","type":"company","lineage":["https://openalex.org/I4210143116"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"B. Masson","raw_affiliation_strings":["Electricit\u00e9 De France (EDF-DIPNN-Technical Direction), Lyon, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electricit\u00e9 De France (EDF-DIPNN-Technical Direction), Lyon, France","institution_ids":["https://openalex.org/I4210143116"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5041968070","https://openalex.org/A5081192545"],"corresponding_institution_ids":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I4210143269","https://openalex.org/I899635006"],"apc_list":{"value":2150,"currency":"USD","value_usd":2150},"apc_paid":{"value":2150,"currency":"USD","value_usd":2150},"fwci":2.9782,"has_fulltext":true,"cited_by_count":27,"citation_normalized_percentile":{"value":0.92607552,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"370","issue":null,"first_page":"110800","last_page":"110800"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10928","display_name":"Probabilistic and Robust Engineering Design","score":0.9496999979019165,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10928","display_name":"Probabilistic and Robust Engineering Design","score":0.9496999979019165,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11850","display_name":"Concrete Corrosion and Durability","score":0.013299999758601189,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11046","display_name":"Geotechnical Engineering and Analysis","score":0.005900000222027302,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/stochastic-finite-element-method","display_name":"stochastic finite element method","score":0.925000011920929},{"id":"https://openalex.org/keywords/nuclear-containment-buildings","display_name":"nuclear containment buildings","score":0.906000018119812},{"id":"https://openalex.org/keywords/serviceability","display_name":"serviceability","score":0.7979999780654907},{"id":"https://openalex.org/keywords/thermo-hydro-mechanical-coupling","display_name":"thermo-hydro-mechanical coupling","score":0.8920000195503235},{"id":"https://openalex.org/keywords/leakage-rate","display_name":"leakage rate","score":0.4269999861717224},{"id":"https://openalex.org/keywords/polynomial-chaos-expansion","display_name":"polynomial chaos expansion","score":0.6759999990463257},{"id":"https://openalex.org/keywords/variance-based-sensitivity-analysis","display_name":"variance-based sensitivity analysis","score":0.75},{"id":"https://openalex.org/keywords/reliability-analysis","display_name":"reliability analysis","score":0.6650000214576721},{"id":"https://openalex.org/keywords/metamodel","display_name":"meta-model","score":0.5109999775886536},{"id":"https://openalex.org/keywords/lifespan-extension","display_name":"lifespan extension","score":0.6430000066757202}],"concepts":[{"id":"https://openalex.org/C110245778","wikidata":"https://www.wikidata.org/wiki/Q2169658","display_name":"Serviceability (structure)","level":2,"score":0.9122639894485474},{"id":"https://openalex.org/C197656079","wikidata":"https://www.wikidata.org/wiki/Q17147719","display_name":"Polynomial chaos","level":3,"score":0.5436694622039795},{"id":"https://openalex.org/C106221998","wikidata":"https://www.wikidata.org/wiki/Q1309811","display_name":"Containment building","level":3,"score":0.5425937175750732},{"id":"https://openalex.org/C113024971","wikidata":"https://www.wikidata.org/wiki/Q1432868","display_name":"Expansion joint","level":2,"score":0.5158159136772156},{"id":"https://openalex.org/C49937458","wikidata":"https://www.wikidata.org/wiki/Q2599292","display_name":"Probabilistic logic","level":2,"score":0.505305826663971},{"id":"https://openalex.org/C135628077","wikidata":"https://www.wikidata.org/wiki/Q220184","display_name":"Finite element method","level":2,"score":0.4792475700378418},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.46689972281455994},{"id":"https://openalex.org/C19499675","wikidata":"https://www.wikidata.org/wiki/Q232207","display_name":"Monte Carlo method","level":2,"score":0.4552735686302185},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4495566487312317},{"id":"https://openalex.org/C175349315","wikidata":"https://www.wikidata.org/wiki/Q1938123","display_name":"Nuclear decommissioning","level":2,"score":0.41686201095581055},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3047122657299042},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.17610326409339905},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.1667163372039795},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C2780004111","wikidata":"https://www.wikidata.org/wiki/Q4672572","display_name":"Accident management","level":2,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1016/j.nucengdes.2020.110800","doi":"https://doi.org/10.1016/j.nucengdes.2020.110800","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.nucengdes.2020.110800","pdf_url":"https://www.sciencedirect.com/science/article/pii/S0029549320302946","source":{"id":"https://openalex.org/S102681701","display_name":"Nuclear Engineering and Design","issn_l":"0029-5493","issn":["0029-5493","1872-759X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-d","jufo-3","norway-1","poland-100","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"Nuclear Engineering and Design","raw_type":"journal-article"},{"id":"pmh:oai:HAL:hal-03492790v1","doi":null,"is_oa":true,"landing_page_url":"https://hal.science/hal-03492790","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4405252976","host_organization_name":"Centre pour la Communication Scientifique Directe","host_organization_lineage":["https://openalex.org/I4405252976"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Nuclear Engineering and Design, 2020, 370, pp.110800 -. &#x27E8;10.1016/j.nucengdes.2020.110800&#x27E9;","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"doi:10.1016/j.nucengdes.2020.110800","doi":"https://doi.org/10.1016/j.nucengdes.2020.110800","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.nucengdes.2020.110800","pdf_url":"https://www.sciencedirect.com/science/article/pii/S0029549320302946","source":{"id":"https://openalex.org/S102681701","display_name":"Nuclear Engineering and Design","issn_l":"0029-5493","issn":["0029-5493","1872-759X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-d","jufo-3","norway-1","poland-100","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"Nuclear Engineering and Design","raw_type":"journal-article"},"sustainable_development_goals":[],"study_designs":[],"awards":[{"id":"https://openalex.org/G1269809734","display_name":"Maitrise du confinement d'une enceinte en accident","funder_award_id":"ANR-11-RSNR-0012","funder_id":"https://openalex.org/F4320320883","funder_display_name":"Agence Nationale de la Recherche"},{"id":"https://openalex.org/G1588080083","display_name":"Evaluation Non Destructives des Enceintes de confinement des centrales nucl\u00e9aires","funder_award_id":"ANR-11-RSNR-0009","funder_id":"https://openalex.org/F4320320883","funder_display_name":"Agence Nationale de la Recherche"},{"id":"https://openalex.org/G2334886279","display_name":"Ing\u00e9nierie de la Complexit\u00e9 : la m\u00e9canique et ses interfaces au service des enjeux soci\u00e9taux du 21i\u00e8","funder_award_id":"ANR-11-LABX-0030","funder_id":"https://openalex.org/F4320320883","funder_display_name":"Agence Nationale de la Recherche"}],"funders":[{"id":"https://openalex.org/F4320320883","display_name":"Agence Nationale de la Recherche","ror":"https://ror.org/00rbzpz17"},{"id":"https://openalex.org/F4320323744","display_name":"\u00c9lectricit\u00e9 de France","ror":"https://ror.org/03wb8xz10"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3091998196.pdf","grobid_xml":"https://content.openalex.org/works/W3091998196.grobid-xml"},"referenced_works_count":91,"referenced_works":["https://openalex.org/W100464641","https://openalex.org/W342873484","https://openalex.org/W622668286","https://openalex.org/W651150315","https://openalex.org/W748494909","https://openalex.org/W999207820","https://openalex.org/W1178601477","https://openalex.org/W1538934584","https://openalex.org/W1876546099","https://openalex.org/W1898954423","https://openalex.org/W1968809267","https://openalex.org/W1978137304","https://openalex.org/W1978808172","https://openalex.org/W1982074547","https://openalex.org/W1983776361","https://openalex.org/W1983983422","https://openalex.org/W1988292964","https://openalex.org/W1989800199","https://openalex.org/W1993787355","https://openalex.org/W2000606551","https://openalex.org/W2007061404","https://openalex.org/W2010737928","https://openalex.org/W2010978143","https://openalex.org/W2012444224","https://openalex.org/W2014558372","https://openalex.org/W2014910287","https://openalex.org/W2018159038","https://openalex.org/W2018549648","https://openalex.org/W2021318928","https://openalex.org/W2025418888","https://openalex.org/W2028507414","https://openalex.org/W2029549014","https://openalex.org/W2032558547","https://openalex.org/W2035520182","https://openalex.org/W2038669746","https://openalex.org/W2042264917","https://openalex.org/W2044662695","https://openalex.org/W2045042756","https://openalex.org/W2045355467","https://openalex.org/W2045737847","https://openalex.org/W2049774453","https://openalex.org/W2053792421","https://openalex.org/W2054278863","https://openalex.org/W2061214666","https://openalex.org/W2067977151","https://openalex.org/W2068969484","https://openalex.org/W2071079138","https://openalex.org/W2072612618","https://openalex.org/W2075072918","https://openalex.org/W2075967518","https://openalex.org/W2076809904","https://openalex.org/W2078686432","https://openalex.org/W2083383885","https://openalex.org/W2083415217","https://openalex.org/W2083593509","https://openalex.org/W2084077710","https://openalex.org/W2087026316","https://openalex.org/W2093237604","https://openalex.org/W2100356276","https://openalex.org/W2101589741","https://openalex.org/W2119519233","https://openalex.org/W2133039442","https://openalex.org/W2148154994","https://openalex.org/W2148682056","https://openalex.org/W2162129805","https://openalex.org/W2165359289","https://openalex.org/W2263376155","https://openalex.org/W2325626901","https://openalex.org/W2477043160","https://openalex.org/W2486444208","https://openalex.org/W2517325148","https://openalex.org/W2523132392","https://openalex.org/W2528846065","https://openalex.org/W2557355724","https://openalex.org/W2585358252","https://openalex.org/W2594705108","https://openalex.org/W2605109830","https://openalex.org/W2795745551","https://openalex.org/W2801064383","https://openalex.org/W2803044936","https://openalex.org/W2809776627","https://openalex.org/W2832980869","https://openalex.org/W2905165737","https://openalex.org/W2914638354","https://openalex.org/W2995161752","https://openalex.org/W4237151101","https://openalex.org/W4240083046","https://openalex.org/W4249431320","https://openalex.org/W4298196151","https://openalex.org/W7046136838","https://openalex.org/W7147267507"],"related_works":["https://openalex.org/W3043110510","https://openalex.org/W2735661400","https://openalex.org/W4417513828","https://openalex.org/W857340409","https://openalex.org/W2367127457","https://openalex.org/W2795745551","https://openalex.org/W3083593679","https://openalex.org/W2801064383","https://openalex.org/W2040905071","https://openalex.org/W2368820612"],"abstract_inverted_index":{"This":[0],"work":[1],"proposes":[2],"a":[3,30,44,60,64,68,85,91,113,125,160,177,185,190,200,213,247,259],"global":[4,165],"Stochastic":[5],"Finite":[6],"Element":[7],"Method":[8,145],"(SFEM)":[9],"to":[10,55,107,148,169],"model":[11],"the":[12,19,82,99,108,122,135,149,229,233,252],"effects":[13],"of":[14,23,47,84,101,124,138,157,176,189,199,216,218,239,254],"concrete":[15],"ageing":[16],"uncertainties":[17],"on":[18,90,258],"serviceability":[20,139],"and":[21,26,40,50,67,116,155,205,226,236],"durability":[22],"large":[24,45,240],"reinforced":[25],"prestressed":[27],"structures":[28],"with":[29,43],"containment":[31,202],"role.":[32],"As":[33],"their":[34],"modelling":[35],"requires":[36],"strongly":[37],"non-linear,":[38],"coupled":[39],"expensive":[41],"calculations":[42],"number":[46],"parameters,":[48],"adapted":[49],"efficient":[51],"probabilistic":[52,187],"strategies":[53],"need":[54],"be":[56,251],"defined":[57],"aiming":[58],"at":[59],"stochastic":[61],"analysis":[62,137,188],"within":[63,159,212],"reasonable":[65],"cost":[66],"physically":[69,191],"admissible":[70,192],"representativeness.":[71],"In":[72],"this":[73,75,164],"contribution,":[74],"is":[76,167,182],"achieved":[77],"through":[78],"four":[79],"steps:":[80],"(a)":[81],"definition":[83],"well-established":[86],"physical":[87],"framework":[88],"based":[89,257],"staggered":[92],"Thermo-Hydro-Mechanical":[93],"+":[94],"Leakage":[95],"(THM-L)":[96],"model;":[97],"(b)":[98],"limitation":[100],"random":[102],"inputs":[103],"for":[104,232],"uncertainty":[105],"propagation":[106],"most":[109],"influential":[110],"ones":[111],"using":[112,129,141],"variance-based":[114],"Hierarchized":[115],"Local":[117],"Sensitivity":[118],"Analysis":[119],"(HLSA);":[120],"(c)":[121],"construction":[123],"THM-L":[126],"response":[127],"metamodel":[128],"Polynomial":[130],"Chaos":[131],"Expansion":[132],"(PCE);":[133],"(d)":[134],"reliability":[136],"criteria":[140],"Crude":[142],"Monte":[143],"Carlo":[144],"(CMCM)":[146],"applied":[147,168],"developed":[150],"metamodel.":[151],"For":[152,242],"validation":[153],"purposes":[154],"demonstration":[156],"achievability":[158],"complex":[161],"industrial":[162],"framework,":[163],"methodology":[166],"an":[170],"experimental":[171],"1:3":[172],"scaled":[173],"Containment":[174,244],"Building":[175],"nuclear":[178,201],"reactor.":[179],"Eventually,":[180],"it":[181],"shown":[183],"that":[184],"complete":[186],"total":[193],"dry":[194],"air":[195],"leakage":[196],"rate":[197],"(indicative":[198],"structure\u2019s":[203],"performance)":[204],"its":[206],"evolution":[207],"in":[208],"time":[209,215],"are":[210],"obtained":[211],"computational":[214],"tens":[217],"days":[219],"only.":[220],"Such":[221],"result":[222],"can":[223],"provide":[224],"insights":[225],"help":[227],"during":[228],"decision-making":[230],"process":[231],"design,":[234],"maintenance":[235],"risk":[237],"assessment":[238],"structures.":[241],"Nuclear":[243],"Buildings":[245],"(NCB),":[246],"direct":[248],"application":[249],"would":[250],"evaluation":[253],"lifespan":[255],"extension":[256],"leakage-rate-defined":[260],"criterion":[261],"under":[262],"operational":[263],"loads.":[264]},"counts_by_year":[{"year":2025,"cited_by_count":6},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":8},{"year":2021,"cited_by_count":5}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2020-10-15T00:00:00"}
