{"id":"https://openalex.org/W3084138014","doi":"https://doi.org/10.1109/icefeet49149.2020.9186956","title":"S-Transform Assisted CUSUM Based Protection Strategy for Transmission Lines Possessing UPFC","display_name":"S-Transform Assisted CUSUM Based Protection Strategy for Transmission Lines Possessing UPFC","publication_year":2020,"publication_date":"2020-07-01","ids":{"openalex":"https://openalex.org/W3084138014","doi":"https://doi.org/10.1109/icefeet49149.2020.9186956","mag":"3084138014"},"language":"en","primary_location":{"id":"doi:10.1109/icefeet49149.2020.9186956","doi":"https://doi.org/10.1109/icefeet49149.2020.9186956","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icefeet49149.2020.9186956","pdf_url":null,"source":{"id":"https://openalex.org/S4363608110","display_name":"International Conference on Emerging Frontiers in Electrical and Electronic Technologies (ICEFEET)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 International Conference on Emerging Frontiers in Electrical and Electronic Technologies (ICEFEET)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5006515404","display_name":"Sauvik Biswas","orcid":"https://orcid.org/0000-0003-0394-0164","observed_orcids":["https://orcid.org/0000-0003-0394-0164"]},"institutions":[{"id":"https://openalex.org/I189109744","display_name":"Indian Institute of Technology Dhanbad","ror":"https://ror.org/013v3cc28","country_code":"IN","type":"education","lineage":["https://openalex.org/I189109744"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sauvik Biswas","raw_affiliation_strings":["Dept. of Electrical Engineering, Indian Institute of Technology (ISM), Dhanbad, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Electrical Engineering, Indian Institute of Technology (ISM), Dhanbad, India","institution_ids":["https://openalex.org/I189109744"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5090377563","display_name":"Vishal Parhi","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I189109744","display_name":"Indian Institute of Technology Dhanbad","ror":"https://ror.org/013v3cc28","country_code":"IN","type":"education","lineage":["https://openalex.org/I189109744"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Vishal Parhi","raw_affiliation_strings":["Dept. of Electrical Engineering, Indian Institute of Technology (ISM), Dhanbad, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Electrical Engineering, Indian Institute of Technology (ISM), Dhanbad, India","institution_ids":["https://openalex.org/I189109744"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082138591","display_name":"Bhatraj Anudeep","orcid":"https://orcid.org/0000-0002-9472-1022","observed_orcids":["https://orcid.org/0000-0002-9472-1022"]},"institutions":[{"id":"https://openalex.org/I189109744","display_name":"Indian Institute of Technology Dhanbad","ror":"https://ror.org/013v3cc28","country_code":"IN","type":"education","lineage":["https://openalex.org/I189109744"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Bhatraj Anudeep","raw_affiliation_strings":["Dept. of Electrical Engineering, Indian Institute of Technology (ISM), Dhanbad, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Electrical Engineering, Indian Institute of Technology (ISM), Dhanbad, India","institution_ids":["https://openalex.org/I189109744"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5041200766","display_name":"Paresh Kumar Nayak","orcid":"https://orcid.org/0000-0001-6853-3266","observed_orcids":["https://orcid.org/0000-0001-6853-3266"]},"institutions":[{"id":"https://openalex.org/I189109744","display_name":"Indian Institute of Technology Dhanbad","ror":"https://ror.org/013v3cc28","country_code":"IN","type":"education","lineage":["https://openalex.org/I189109744"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Paresh Kumar Nayak","raw_affiliation_strings":["Dept. of Electrical Engineering, Indian Institute of Technology (ISM), Dhanbad, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Electrical Engineering, Indian Institute of Technology (ISM), Dhanbad, India","institution_ids":["https://openalex.org/I189109744"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I189109744"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.001500000013038516,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/unified-power-flow-controller","display_name":"unified power flow controller","score":0.9919999837875366},{"id":"https://openalex.org/keywords/transmission-line-protection","display_name":"transmission line protection","score":0.8130000233650208},{"id":"https://openalex.org/keywords/distance-protection","display_name":"distance protection","score":0.7409999966621399},{"id":"https://openalex.org/keywords/cusum","display_name":"CUSUM","score":0.7739999890327454},{"id":"https://openalex.org/keywords/s-transform","display_name":"S-transform","score":0.9409999847412109},{"id":"https://openalex.org/keywords/fault-detection","display_name":"fault detection","score":0.9580000042915344},{"id":"https://openalex.org/keywords/fault-classification","display_name":"fault classification","score":0.9980000257492065},{"id":"https://openalex.org/keywords/impedance-measurement","display_name":"impedance measurement","score":0.3659999966621399}],"concepts":[{"id":"https://openalex.org/C2776352172","wikidata":"https://www.wikidata.org/wiki/Q2494266","display_name":"Unified power flow controller","level":5,"score":0.9403476715087891},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.7035589814186096},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6715946793556213},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.6299735903739929},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6284044981002808},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.6279534101486206},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.5841180086135864},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5136701464653015},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5121533870697021},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.48824313282966614},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.478839635848999},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4515846371650696},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4066256582736969},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.39613914489746094},{"id":"https://openalex.org/C2986056383","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power flow","level":4,"score":0.3831225633621216},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3673146367073059},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1798098385334015},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.15904587507247925},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.1212453842163086},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.09433501958847046},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07620817422866821},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icefeet49149.2020.9186956","doi":"https://doi.org/10.1109/icefeet49149.2020.9186956","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icefeet49149.2020.9186956","pdf_url":null,"source":{"id":"https://openalex.org/S4363608110","display_name":"International Conference on Emerging Frontiers in Electrical and Electronic Technologies (ICEFEET)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 International Conference on Emerging Frontiers in Electrical and Electronic Technologies (ICEFEET)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":1.0}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1489718105","https://openalex.org/W1986754283","https://openalex.org/W2061661854","https://openalex.org/W2078449043","https://openalex.org/W2085017140","https://openalex.org/W2109560907","https://openalex.org/W2137995127","https://openalex.org/W2147235729","https://openalex.org/W2296049024","https://openalex.org/W2740318485","https://openalex.org/W2790632405","https://openalex.org/W2964958530","https://openalex.org/W3001378718","https://openalex.org/W4231507190"],"related_works":["https://openalex.org/W2588181078","https://openalex.org/W2146059864","https://openalex.org/W2323146556","https://openalex.org/W2129890619","https://openalex.org/W2964958530","https://openalex.org/W4391807817","https://openalex.org/W4409427404","https://openalex.org/W2545503424","https://openalex.org/W2594876511","https://openalex.org/W2321955837"],"abstract_inverted_index":{"The":[0,78,108],"different":[1,90],"operating":[2],"modes":[3],"of":[4,56,80,121],"unified":[5],"power":[6,103],"flow":[7],"controller":[8],"(UPFC)":[9],"affect":[10],"the":[11,16,20,32,45,54,81,114,119,122],"voltage,":[12],"current":[13],"and":[14,26,64,67,73,98,110],"hence":[15],"measured":[17],"impedance":[18,39],"at":[19],"relay":[21,35],"location":[22],"both":[23],"during":[24],"steady-state":[25],"transient":[27],"conditions.":[28],"As":[29],"a":[30,65,94],"result,":[31],"conventional":[33],"distance":[34,59],"based":[36,70],"on":[37,58,93],"fixed":[38],"setting":[40],"finds":[41],"difficulty":[42],"in":[43],"protecting":[44],"UPFC":[46,57,101,127],"compensated":[47,128],"transmission":[48],"line":[49],"(TL).":[50],"In":[51],"this":[52],"paper,":[53],"effect":[55],"protection":[60],"is":[61,76,84],"studied":[62],"explicitly":[63],"Fortescue":[66],"Stockwell":[68],"transform":[69],"fault":[71,91],"detection":[72],"classification":[74],"scheme":[75,116],"proposed.":[77],"functioning":[79],"proposed":[82,115,123],"technique":[83,125],"evaluated":[85],"by":[86],"simulating":[87],"data":[88],"for":[89,113,126],"cases":[92],"400":[95],"kV":[96],"two-bus":[97],"double":[99],"circuited":[100],"installed":[102],"system":[104],"through":[105],"EMTDC/PSCAD":[106],"software.":[107],"fast":[109],"accurate":[111],"results":[112],"clearly":[117],"justify":[118],"efficacy":[120],"relaying":[124],"line.":[129]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":3}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2020-09-14T00:00:00"}