{"id":"https://openalex.org/W3048204331","doi":"https://doi.org/10.1109/eic47619.2020.9158719","title":"Development And Implementation Of An In-Situ Cable Condition Monitoring Method For Nuclear Power Plants","display_name":"Development And Implementation Of An In-Situ Cable Condition Monitoring Method For Nuclear Power Plants","publication_year":2020,"publication_date":"2020-06-01","ids":{"openalex":"https://openalex.org/W3048204331","doi":"https://doi.org/10.1109/eic47619.2020.9158719","mag":"3048204331"},"language":"en","primary_location":{"id":"doi:10.1109/eic47619.2020.9158719","doi":"https://doi.org/10.1109/eic47619.2020.9158719","is_oa":false,"landing_page_url":"https://doi.org/10.1109/eic47619.2020.9158719","pdf_url":null,"source":{"id":"https://openalex.org/S7407086244","display_name":"IEEE Electrical Insulation Conference (EIC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE Electrical Insulation Conference (EIC)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5010195168","display_name":"Gary Harmon","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210149181","display_name":"Analysis and Measurement Services (United States)","ror":"https://ror.org/056s1k160","country_code":"US","type":"company","lineage":["https://openalex.org/I4210149181"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Gary Harmon","raw_affiliation_strings":["Analysis and Measurement Services Corporation, Knoxville, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Analysis and Measurement Services Corporation, Knoxville, USA","institution_ids":["https://openalex.org/I4210149181"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5026650387","display_name":"Trevor A. Toll","orcid":"https://orcid.org/0000-0002-6587-6383","observed_orcids":["https://orcid.org/0000-0002-6587-6383"]},"institutions":[{"id":"https://openalex.org/I4210149181","display_name":"Analysis and Measurement Services (United States)","ror":"https://ror.org/056s1k160","country_code":"US","type":"company","lineage":["https://openalex.org/I4210149181"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Trevor Toll","raw_affiliation_strings":["Analysis and Measurement Services Corporation, Knoxville, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Analysis and Measurement Services Corporation, Knoxville, USA","institution_ids":["https://openalex.org/I4210149181"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5032369427","display_name":"Casey D. Sexton","orcid":"https://orcid.org/0000-0002-8193-5857","observed_orcids":["https://orcid.org/0000-0002-8193-5857"]},"institutions":[{"id":"https://openalex.org/I4210149181","display_name":"Analysis and Measurement Services (United States)","ror":"https://ror.org/056s1k160","country_code":"US","type":"company","lineage":["https://openalex.org/I4210149181"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Casey Sexton","raw_affiliation_strings":["Analysis and Measurement Services Corporation, Knoxville, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Analysis and Measurement Services Corporation, Knoxville, USA","institution_ids":["https://openalex.org/I4210149181"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4210149181"],"apc_list":null,"apc_paid":null,"fwci":1.0517,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.71138548,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"33","last_page":"36"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.5845000147819519,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.5845000147819519,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.3292999863624573,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.03519999980926514,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cable-condition-monitoring","display_name":"cable condition monitoring","score":0.972000002861023},{"id":"https://openalex.org/keywords/nuclear-power-plant-cables","display_name":"nuclear power plant cables","score":0.9120000004768372},{"id":"https://openalex.org/keywords/frequency-domain-reflectometry","display_name":"frequency domain reflectometry","score":0.9959999918937683},{"id":"https://openalex.org/keywords/cable-insulation-degradation","display_name":"cable insulation degradation","score":0.7310000061988831},{"id":"https://openalex.org/keywords/elongation-at-break","display_name":"elongation at break","score":0.7900000214576721},{"id":"https://openalex.org/keywords/cable-aging","display_name":"cable aging","score":0.6650000214576721},{"id":"https://openalex.org/keywords/non-destructive-testing","display_name":"non-destructive testing","score":0.7649999856948853},{"id":"https://openalex.org/keywords/transmission-line-theory","display_name":"transmission line theory","score":0.7020000219345093},{"id":"https://openalex.org/keywords/impedance-measurement","display_name":"impedance measurement","score":0.40400001406669617}],"concepts":[{"id":"https://openalex.org/C513653683","wikidata":"https://www.wikidata.org/wiki/Q12739","display_name":"Nuclear power","level":2,"score":0.7014151811599731},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6494713425636292},{"id":"https://openalex.org/C2779979336","wikidata":"https://www.wikidata.org/wiki/Q134447","display_name":"Nuclear power plant","level":2,"score":0.5776407718658447},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5685070753097534},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4828501343727112},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.4798390567302704},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.43629902601242065},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3643779158592224},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.35609716176986694},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3248768150806427},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0},{"id":"https://openalex.org/C185544564","wikidata":"https://www.wikidata.org/wiki/Q81197","display_name":"Nuclear physics","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/eic47619.2020.9158719","doi":"https://doi.org/10.1109/eic47619.2020.9158719","is_oa":false,"landing_page_url":"https://doi.org/10.1109/eic47619.2020.9158719","pdf_url":null,"source":{"id":"https://openalex.org/S7407086244","display_name":"IEEE Electrical Insulation Conference (EIC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE Electrical Insulation Conference (EIC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.8970999717712402}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W3132239985","https://openalex.org/W2565664755","https://openalex.org/W2760835487","https://openalex.org/W2566757196","https://openalex.org/W2802117853","https://openalex.org/W967693543","https://openalex.org/W3215050323","https://openalex.org/W2129539697","https://openalex.org/W2409704298","https://openalex.org/W3128694165"],"abstract_inverted_index":{"The":[0,93],"sustainability":[1],"of":[2,6,18,58,85,105,141,201,228],"the":[3,16,37,43,52,101,124,139,161,182,189,199,225],"existing":[4],"fleet":[5],"nuclear":[7,59,112,205],"power":[8,113],"reactors":[9],"depends":[10],"on":[11,49,100,123],"utilities'":[12],"ability":[13,242],"to":[14,50,68,145,188,197,215,223,240,243],"manage":[15],"aging":[17,226],"key":[19,40,65],"components":[20,41,66],"that":[21,42,63,82,137,174],"cannot":[22],"easily":[23],"or":[24,28],"economically":[25],"be":[26,80,235],"replaced":[27],"upgraded.":[29],"Cables,":[30],"metals,":[31],"and":[32,39,45,56,75,87,103,147,159,218],"concrete":[33],"structures":[34],"are":[35,47,83],"among":[36],"major":[38],"industry":[44,190],"government":[46],"working":[48],"ensure":[51,62],"long":[53,212],"term":[54,213],"reliability":[55],"safety":[57],"plants.":[60],"To":[61],"these":[64,91],"continue":[67],"meet":[69],"their":[70],"performance":[71],"requirements,":[72],"new":[73],"testing":[74],"condition":[76,108,118,171,227],"monitoring":[77,109,119,172],"technologies":[78],"must":[79],"developed":[81],"capable":[84],"identifying":[86],"quantifying":[88],"degradation":[89,203],"in":[90,96,151,204,238],"materials.":[92],"work":[94],"presented":[95],"this":[97],"paper":[98],"focuses":[99],"development":[102],"implementation":[104],"an":[106],"in-situ":[107,134],"method":[110,120,173],"for":[111],"plant":[114,206],"cables.":[115],"This":[116],"cable":[117,153,170,178,207],"is":[121,131],"based":[122],"frequency":[125],"domain":[126],"reflectometry":[127],"(FDR)":[128],"technique,":[129],"which":[130],"a":[132,152,169],"nondestructive":[133],"electrical":[135],"test":[136,163,196],"uses":[138],"principle":[140],"transmission":[142],"line":[143],"theory":[144],"locate":[146],"quantify":[148,198],"impedance":[149],"changes":[150],"circuit.":[154],"Through":[155],"extensive":[156],"research,":[157],"development,":[158],"validation,":[160],"FDR":[162,183,222],"technique":[164],"has":[165,185],"been":[166,186],"adapted":[167],"as":[168],"trends":[175],"with":[176],"increasing":[177],"degradation.":[179],"In":[180],"addition,":[181],"data":[184],"correlated":[187],"standard":[191],"elongation":[192],"at":[193],"break":[194],"(EAB)":[195],"degree":[200],"localized":[202],"insulation":[208],"material":[209],"caused":[210],"by":[211],"exposure":[214],"high":[216],"temperatures":[217],"radiation.":[219],"By":[220],"correlating":[221],"EAB,":[224],"cables":[229],"routed":[230],"through":[231],"harsh":[232],"environments":[233],"can":[234],"better":[236],"understood":[237],"relation":[239],"its":[241,245],"perform":[244],"intended":[246],"function.":[247]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":1}],"updated_date":"2026-10-09T09:14:12.587421","created_date":"2020-08-13T00:00:00"}
