{"id":"https://openalex.org/W3036640459","doi":"https://doi.org/10.1088/1755-1315/512/1/012128","title":"Reliability Evaluation Method of Low-voltage Distribution Network Based on Linear Equation","display_name":"Reliability Evaluation Method of Low-voltage Distribution Network Based on Linear Equation","publication_year":2020,"publication_date":"2020-06-01","ids":{"openalex":"https://openalex.org/W3036640459","doi":"https://doi.org/10.1088/1755-1315/512/1/012128","mag":"3036640459"},"language":"en","primary_location":{"id":"doi:10.1088/1755-1315/512/1/012128","doi":"https://doi.org/10.1088/1755-1315/512/1/012128","is_oa":true,"landing_page_url":"https://doi.org/10.1088/1755-1315/512/1/012128","pdf_url":"https://iopscience.iop.org/article/10.1088/1755-1315/512/1/012128/pdf","source":{"id":"https://openalex.org/S4210195883","display_name":"IOP Conference Series Earth and Environmental Science","issn_l":"1755-1315","issn":["1755-1315","1755-1307"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":["norway-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IOP Conference Series: Earth and Environmental Science","raw_type":"journal-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://iopscience.iop.org/article/10.1088/1755-1315/512/1/012128/pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5034904632","display_name":"Qinglong Liao","orcid":"https://orcid.org/0000-0003-1692-0429","observed_orcids":["https://orcid.org/0000-0003-1692-0429"]},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qinglong Liao","raw_affiliation_strings":["State Grid Chongqing Electric Power Research Institute, Chongqing, 404100, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Chongqing Electric Power Research Institute, Chongqing, 404100, China","institution_ids":["https://openalex.org/I17442442"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001778158","display_name":"Lingyun Wan","orcid":"https://orcid.org/0000-0001-5764-7364","observed_orcids":["https://orcid.org/0000-0001-5764-7364","https://orcid.org/0009-0008-9959-9741"]},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Lingyun Wan","raw_affiliation_strings":["State Grid Chongqing Electric Power Research Institute, Chongqing, 404100, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Chongqing Electric Power Research Institute, Chongqing, 404100, China","institution_ids":["https://openalex.org/I17442442"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100405620","display_name":"Ying Zhang","orcid":"https://orcid.org/0000-0002-9964-9381","observed_orcids":["https://orcid.org/0000-0002-9964-9381","https://orcid.org/0009-0005-1639-327X"]},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ying Zhang","raw_affiliation_strings":["State Grid Chongqing Electric Power Research Institute, Chongqing, 404100, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Chongqing Electric Power Research Institute, Chongqing, 404100, China","institution_ids":["https://openalex.org/I17442442"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047465070","display_name":"Yang Qunying","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405270698","display_name":"State Grid Chongqing Electric Power Company (China)","ror":"https://ror.org/016cp1m28","country_code":"CN","type":"company","lineage":["https://openalex.org/I4405270698"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qunying Yang","raw_affiliation_strings":["Grid Chongqing Electric Power Company, Chongqing, 404100, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Grid Chongqing Electric Power Company, Chongqing, 404100, China","institution_ids":["https://openalex.org/I4405270698"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112503800","display_name":"Hui Dai","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405270698","display_name":"State Grid Chongqing Electric Power Company (China)","ror":"https://ror.org/016cp1m28","country_code":"CN","type":"company","lineage":["https://openalex.org/I4405270698"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hui Dai","raw_affiliation_strings":["Grid Chongqing Electric Power Company, Chongqing, 404100, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Grid Chongqing Electric Power Company, Chongqing, 404100, China","institution_ids":["https://openalex.org/I4405270698"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017941662","display_name":"Kaigui Xie","orcid":"https://orcid.org/0000-0002-7057-4304","observed_orcids":["https://orcid.org/0000-0002-7057-4304"]},"institutions":[{"id":"https://openalex.org/I158842170","display_name":"Chongqing University","ror":"https://ror.org/023rhb549","country_code":"CN","type":"education","lineage":["https://openalex.org/I158842170"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Kaigui Xie","raw_affiliation_strings":["State Key Laboratory of Power Transmission Equipment & System Security, College of Electrical Engineering, Chongqing University, Chongqing, 400044, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment & System Security, College of Electrical Engineering, Chongqing University, Chongqing, 400044, China","institution_ids":["https://openalex.org/I158842170"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028864691","display_name":"Bo Hu","orcid":"https://orcid.org/0000-0002-0844-3303","observed_orcids":["https://orcid.org/0000-0002-0844-3303"]},"institutions":[{"id":"https://openalex.org/I158842170","display_name":"Chongqing University","ror":"https://ror.org/023rhb549","country_code":"CN","type":"education","lineage":["https://openalex.org/I158842170"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Bo Hu","raw_affiliation_strings":["State Key Laboratory of Power Transmission Equipment & System Security, College of Electrical Engineering, Chongqing University, Chongqing, 400044, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment & System Security, College of Electrical Engineering, Chongqing University, Chongqing, 400044, China","institution_ids":["https://openalex.org/I158842170"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100459320","display_name":"Dongyang Li","orcid":"https://orcid.org/0000-0003-0818-2526","observed_orcids":["https://orcid.org/0000-0003-0818-2526","https://orcid.org/0000-0002-1247-3329"]},"institutions":[{"id":"https://openalex.org/I158842170","display_name":"Chongqing University","ror":"https://ror.org/023rhb549","country_code":"CN","type":"education","lineage":["https://openalex.org/I158842170"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Dongyang Li","raw_affiliation_strings":["State Key Laboratory of Power Transmission Equipment & System Security, College of Electrical Engineering, Chongqing University, Chongqing, 400044, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Power Transmission Equipment & System Security, College of Electrical Engineering, Chongqing University, Chongqing, 400044, China","institution_ids":["https://openalex.org/I158842170"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.1687,"has_fulltext":true,"cited_by_count":4,"citation_normalized_percentile":{"value":0.85933881,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":95},"biblio":{"volume":"512","issue":"1","first_page":"012128","last_page":"012128"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/low-voltage-distribution-networks","display_name":"low-voltage distribution networks","score":0.968999981880188},{"id":"https://openalex.org/keywords/power-system-reliability","display_name":"power system reliability","score":0.7099999785423279},{"id":"https://openalex.org/keywords/analytical-reliability-model","display_name":"analytical reliability model","score":0.777999997138977},{"id":"https://openalex.org/keywords/power-outage-frequency","display_name":"power outage frequency","score":0.8119999766349792},{"id":"https://openalex.org/keywords/load-point-reliability","display_name":"load point reliability","score":0.6420000195503235},{"id":"https://openalex.org/keywords/network-topology","display_name":"network topology","score":0.7049999833106995}],"concepts":[{"id":"https://openalex.org/C2777693866","wikidata":"https://www.wikidata.org/wiki/Q359099","display_name":"Blackout","level":4,"score":0.8249721527099609},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.6896888613700867},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.5772535800933838},{"id":"https://openalex.org/C62611344","wikidata":"https://www.wikidata.org/wiki/Q1062658","display_name":"Node (physics)","level":2,"score":0.5705650448799133},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5267521739006042},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.4909694492816925},{"id":"https://openalex.org/C191172861","wikidata":"https://www.wikidata.org/wiki/Q7899321","display_name":"Upstream (networking)","level":2,"score":0.4870639145374298},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4809383749961853},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4479047954082489},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.44066131114959717},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4327227473258972},{"id":"https://openalex.org/C23917780","wikidata":"https://www.wikidata.org/wiki/Q50698","display_name":"Algebraic equation","level":3,"score":0.430791974067688},{"id":"https://openalex.org/C28719098","wikidata":"https://www.wikidata.org/wiki/Q44946","display_name":"Point (geometry)","level":2,"score":0.4187331199645996},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.3293108344078064},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.25520822405815125},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1763666272163391},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.161440908908844},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.08255168795585632},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.08225291967391968},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1088/1755-1315/512/1/012128","doi":"https://doi.org/10.1088/1755-1315/512/1/012128","is_oa":true,"landing_page_url":"https://doi.org/10.1088/1755-1315/512/1/012128","pdf_url":"https://iopscience.iop.org/article/10.1088/1755-1315/512/1/012128/pdf","source":{"id":"https://openalex.org/S4210195883","display_name":"IOP Conference Series Earth and Environmental Science","issn_l":"1755-1315","issn":["1755-1315","1755-1307"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":["norway-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IOP Conference Series: Earth and Environmental Science","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1088/1755-1315/512/1/012128","doi":"https://doi.org/10.1088/1755-1315/512/1/012128","is_oa":true,"landing_page_url":"https://doi.org/10.1088/1755-1315/512/1/012128","pdf_url":"https://iopscience.iop.org/article/10.1088/1755-1315/512/1/012128/pdf","source":{"id":"https://openalex.org/S4210195883","display_name":"IOP Conference Series Earth and Environmental Science","issn_l":"1755-1315","issn":["1755-1315","1755-1307"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":["norway-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IOP Conference Series: Earth and Environmental Science","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.6773999929428101,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320335967","display_name":"Science and Technology Project of State Grid","ror":null}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3036640459.pdf","grobid_xml":"https://content.openalex.org/works/W3036640459.grobid-xml"},"referenced_works_count":9,"referenced_works":["https://openalex.org/W2355309211","https://openalex.org/W2356555112","https://openalex.org/W2357221330","https://openalex.org/W2360787269","https://openalex.org/W2361000451","https://openalex.org/W2362332158","https://openalex.org/W2393201533","https://openalex.org/W2547854284","https://openalex.org/W2794569158"],"related_works":["https://openalex.org/W2372441766","https://openalex.org/W1761605383","https://openalex.org/W6907380963","https://openalex.org/W3033752375","https://openalex.org/W2401701080","https://openalex.org/W2737508326","https://openalex.org/W2033594793","https://openalex.org/W1965268446","https://openalex.org/W2909967461","https://openalex.org/W7213219869"],"abstract_inverted_index":{"Abstract":[0],"The":[1,16,134],"research":[2],"on":[3,33],"the":[4,34,54,57,63,69,74,79,86,92,105,114,120,142,154,166],"reliability":[5,143],"of":[6,37,62,68,78,113,145,170],"distribution":[7,21,39,50],"network":[8,25,81,116],"uses":[9],"simulation":[10],"method":[11,14],"or":[12],"analytical":[13,46],"widely.":[15],"existing":[17],"analysis":[18,27],"methods":[19],"for":[20,28,48,165],"networks":[22],"usually":[23],"require":[24],"topology":[26],"a":[29,44,163],"single":[30],"node.":[31],"Based":[32],"topological":[35],"relationship":[36,55],"low-voltage":[38,49],"network,":[40],"this":[41,138],"paper":[42],"proposes":[43],"new":[45],"model":[47,135],"network.":[51],"Firstly,":[52],"using":[53,149],"between":[56],"upstream":[58],"and":[59,73,91,109,125,153,158,168],"downstream":[60],"nodes":[61],"line,":[64],"an":[65],"algebraic":[66,151],"equation":[67],"expected":[70,75,87,93,121,126],"blackout":[71,76],"time":[72,90,129],"frequency":[77,96,124],"entire":[80,115],"could":[82],"be":[83,102],"construct.":[84],"Secondly,":[85],"power":[88,94,122,127],"outage":[89,95,123,128],"at":[97,130],"each":[98,131,146],"load":[99,110,132,147],"point":[100,148],"can":[101,140,161],"calculate.":[103],"Finally,":[104],"average":[106],"availability":[107],"index":[108,144],"loss":[111],"expectations":[112],"are":[117],"calculate":[118],"from":[119],"point.":[133],"proposed":[136],"in":[137],"article":[139],"determine":[141],"fewer":[150],"equations,":[152],"calculation":[155],"is":[156],"fast":[157],"accurate,":[159],"which":[160],"provide":[162],"reference":[164],"planning":[167],"operation":[169],"distribution.":[171]},"counts_by_year":[{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1}],"updated_date":"2026-10-29T09:56:32.521200","created_date":"2020-06-25T00:00:00"}
