{"id":"https://openalex.org/W3033299746","doi":null,"title":"Interior moisture design loads for residences","display_name":"Interior moisture design loads for residences","publication_year":2001,"publication_date":"2001-01-01","ids":{"openalex":"https://openalex.org/W3033299746","mag":"3033299746"},"language":"en","primary_location":{"id":"pmh:oai:CiteSeerX.psu:10.1.1.467.7234","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.467.7234","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://www.fpl.fs.fed.us/documnts/pdf2001/tenwo01c.pdf","raw_type":"text"},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5073147397","display_name":"Anton TenWolde","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Anton TenWolde","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5055706204","display_name":"Iain S. Walker","orcid":"https://orcid.org/0000-0001-9667-1797","observed_orcids":["https://orcid.org/0000-0001-9667-1797"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Iain S. Walker","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0001-9667-1797","affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.1519,"has_fulltext":false,"cited_by_count":29,"citation_normalized_percentile":{"value":0.86152136,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":96},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12105","display_name":"Hygrothermal properties of building materials","score":0.9053000211715698,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12105","display_name":"Hygrothermal properties of building materials","score":0.9053000211715698,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.07689999788999557,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.006200000178068876,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/residential-buildings","display_name":"residential buildings","score":0.675000011920929},{"id":"https://openalex.org/keywords/indoor-humidity","display_name":"indoor humidity","score":0.7149999737739563},{"id":"https://openalex.org/keywords/moisture-control-in-buildings","display_name":"moisture control in buildings","score":0.7269999980926514},{"id":"https://openalex.org/keywords/moisture-release","display_name":"moisture release","score":0.7599999904632568},{"id":"https://openalex.org/keywords/ventilation","display_name":"ventilation","score":0.7139999866485596},{"id":"https://openalex.org/keywords/dehumidification","display_name":"dehumidification","score":0.9470000267028809},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"air conditioning","score":0.5820000171661377},{"id":"https://openalex.org/keywords/design-criteria","display_name":"design criteria","score":0.3880000114440918}],"concepts":[{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5148986577987671},{"id":"https://openalex.org/C176864760","wikidata":"https://www.wikidata.org/wiki/Q217651","display_name":"Moisture","level":2,"score":0.5120764374732971},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.3387933075428009},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.29688793420791626},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.2790175974369049},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.25693702697753906}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:CiteSeerX.psu:10.1.1.467.7234","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.467.7234","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://www.fpl.fs.fed.us/documnts/pdf2001/tenwo01c.pdf","raw_type":"text"},{"id":"mag:3033299746","doi":null,"is_oa":false,"landing_page_url":"https://www.fpl.fs.fed.us/documnts/pdf2001/tenwo01c.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W2047855710","https://openalex.org/W2114021272","https://openalex.org/W2322761342"],"related_works":["https://openalex.org/W211795899","https://openalex.org/W7097670315","https://openalex.org/W2739202896","https://openalex.org/W2731845324","https://openalex.org/W2126775901","https://openalex.org/W2183307343","https://openalex.org/W2411492114","https://openalex.org/W2183722006","https://openalex.org/W2490640387","https://openalex.org/W1969817805"],"abstract_inverted_index":{"This":[0,19,108],"paper":[1,109,245],"outlines":[2],"a":[3,23,60,75,87,120,138],"methodology":[4],"to":[5,39,58,122,192,219,238],"obtain":[6],"design":[7,15,44,84,102,114,125,168,175],"values":[8],"for":[9,13,17,34,42,63,70,101,116,128,227,232],"indoor":[10,126,169,203],"boundary":[11,71,93],"conditions":[12,72,94],"moisture":[14,43,64,83,113,141,146,178,207,235],"calculations":[16,229],"residences.":[18],"is":[20,55,137,157,186,190],"part":[21],"of":[22,81,86,92,140,196,212],"larger":[24],"effort":[25],"by":[26,202],"ASHRAE":[27],"Standard":[28],"Project":[29],"Committee":[30],"160P,":[31],"Design":[32],"Criteria":[33],"Moisture":[35],"Control":[36],"in":[37,148,151,234],"Buildings,":[38],"formulate":[40],"criteria":[41],"loads,":[45],"analysis":[46,65,85],"techniques,":[47],"and":[48,50,66,89,118,131,145,177,251],"material":[49],"building":[51],"performance.":[52],"The":[53,68,134],"standard":[54],"being":[56],"developed":[57],"provide":[59],"consistent":[61],"framework":[62],"design.":[67],"assumptions":[69],"can":[73,171],"have":[74],"large":[76],"influence":[77],"on":[78,105,111],"the":[79,82,90,97,106,124,149,152,155,163,184,194,209,213,223,248],"results":[80],"building,":[88],"choice":[91],"may":[95],"be":[96,172],"most":[98],"important":[99],"determinant":[100],"recommendations":[103],"based":[104],"analysis.":[107],"focuses":[110],"inte-rior":[112],"loads":[115],"residences":[117],"proposes":[119],"procedure":[121],"estimate":[123],"humidity":[127,136,170],"both":[129],"winter":[130],"summer":[132],"conditions.":[133],"interior":[135],"function":[139],"release,":[142],"ventilation,":[143],"dehumidification,":[144],"storage":[147],"materials":[150],"building.":[153],"If":[154],"home":[156],"not":[158,242],"air":[159],"conditioned":[160],"or":[161,165],"dehumidified,":[162],"weekly":[164],"monthly":[166],"average":[167],"calculated":[173],"from":[174],"ventilation":[176],"release.":[179],"In":[180],"an":[181,197],"air-conditioned":[182],"home,":[183],"situation":[185],"more":[187],"complex.":[188],"It":[189],"difficult":[191],"quantify":[193],"dehumidification":[195],"air-conditioning":[198,214],"system":[199,239],"typically":[200],"controlled":[201],"temperature":[204],"rather":[205],"than":[206],"because":[208],"cycling":[210,240],"frequency":[211],"equipment":[215],"affects":[216],"its":[217],"ability":[218],"remove":[220],"moisture.":[221],"Although":[222],"specific":[224],"data":[225],"required":[226],"sophisticated":[228],"that":[230],"account":[231],"changes":[233],"removal":[236],"due":[237],"are":[241],"available,":[243],"this":[244],"will":[246],"discuss":[247],"issues":[249],"involved":[250],"describe":[252],"simplified":[253],"alternative":[254],"approaches.":[255]},"counts_by_year":[{"year":2024,"cited_by_count":3},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":1}],"updated_date":"2026-11-10T11:39:43.021295","created_date":"2020-06-12T00:00:00"}
