{"id":"https://openalex.org/W3028558998","doi":null,"title":"Neural-based air-handling unit for indoor relative humidity and temperature control.","display_name":"Neural-based air-handling unit for indoor relative humidity and temperature control.","publication_year":2005,"publication_date":"2005-01-01","ids":{"openalex":"https://openalex.org/W3028558998","mag":"3028558998"},"language":"en","primary_location":{"id":"mag:3028558998","doi":null,"is_oa":false,"landing_page_url":"https://iifiir.org/en/fridoc/22907","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075397395","display_name":"Q Zhang","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Q Zhang","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077087921","display_name":"S.C. Fok","orcid":"https://orcid.org/0000-0003-4714-6392","observed_orcids":["https://orcid.org/0000-0003-4714-6392"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"S.C. Fok","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0003-4714-6392","affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5018422848","display_name":"Y.W. Wong","orcid":"https://orcid.org/0000-0002-2969-3950","observed_orcids":["https://orcid.org/0000-0002-2969-3950"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Y.W. Wong","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0002-2969-3950","affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":5.104,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.94674797,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":96},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.8974999785423279,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.8974999785423279,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.026100000366568565,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10320","display_name":"Neural Networks and Applications","score":0.017400000244379044,"subfield":{"id":"https://openalex.org/subfields/1702","display_name":"Artificial Intelligence"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/air-handling-units","display_name":"air handling units","score":0.9789999723434448},{"id":"https://openalex.org/keywords/indoor-humidity-control","display_name":"indoor humidity control","score":0.8009999990463257},{"id":"https://openalex.org/keywords/indoor-temperature-control","display_name":"indoor temperature control","score":0.8569999933242798},{"id":"https://openalex.org/keywords/neural-network","display_name":"artificial neural networks","score":0.7300000190734863},{"id":"https://openalex.org/keywords/backpropagation-through-time","display_name":"backpropagation through time","score":0.871999979019165},{"id":"https://openalex.org/keywords/online-system-identification","display_name":"online system identification","score":0.5099999904632568},{"id":"https://openalex.org/keywords/fan-speed-control","display_name":"fan speed control","score":0.7620000243186951},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"air conditioning","score":0.7009999752044678},{"id":"https://openalex.org/keywords/intelligent-controller","display_name":"intelligent controller","score":0.503000020980835},{"id":"https://openalex.org/keywords/nonlinear-control","display_name":"nonlinear control","score":0.6480000019073486}],"concepts":[{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.6779083013534546},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.6625726222991943},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.6348504424095154},{"id":"https://openalex.org/C82327864","wikidata":"https://www.wikidata.org/wiki/Q835100","display_name":"Intelligent control","level":2,"score":0.588690996170044},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.5133642554283142},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.5090484023094177},{"id":"https://openalex.org/C151420433","wikidata":"https://www.wikidata.org/wiki/Q180600","display_name":"Humidity","level":2,"score":0.4850272536277771},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.45142048597335815},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.44719812273979187},{"id":"https://openalex.org/C47116090","wikidata":"https://www.wikidata.org/wiki/Q716829","display_name":"PID controller","level":3,"score":0.4464520514011383},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.43822047114372253},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.4321483373641968},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3881187438964844},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.36578118801116943},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.33252185583114624},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.15592443943023682},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.11023041605949402},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.08578196167945862},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.07233759760856628},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:3028558998","doi":null,"is_oa":false,"landing_page_url":"https://iifiir.org/en/fridoc/22907","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2527464302","https://openalex.org/W1928691699","https://openalex.org/W2207487888","https://openalex.org/W2389218439","https://openalex.org/W2164683828","https://openalex.org/W2154592874","https://openalex.org/W4254434075","https://openalex.org/W2362483453","https://openalex.org/W2393281449","https://openalex.org/W2992443747"],"abstract_inverted_index":{"The":[0,20,60,74,94],"paper":[1],"proposes":[2],"an":[3,7,36,66],"intelligent":[4,80,101],"controller":[5,46,62,81],"for":[6,70,106],"air-handling":[8],"unit":[9],"to":[10,34,38,47],"control":[11,48,84],"the":[12,16,26,41,49,79,85,90,98],"temperature":[13,86],"while":[14],"limiting":[15],"humidity":[17,88],"below":[18],"70%.":[19],"proposed":[21],"scheme":[22],"is":[23],"based":[24],"on":[25,65],"back-propagation-through-time":[27],"approach.":[28],"It":[29],"uses":[30],"artificial":[31],"neural":[32],"networks":[33],"develop":[35],"emulator":[37],"learn":[39],"on-line":[40],"plant":[42],"dynamics":[43],"and":[44,52,87,109],"a":[45],"fan":[50],"speed":[51],"chilled":[53],"water":[54],"valve":[55],"opening":[56],"in":[57],"real":[58],"time.":[59],"neural-based":[61],"was":[63],"implemented":[64],"industrial":[67],"air":[68],"handler":[69],"performance":[71],"validation":[72],"purposes.":[73],"implementation":[75],"results":[76,95],"show":[77],"that":[78],"could":[82],"effectively":[83],"within":[89],"operating":[91],"range":[92],"investigated.":[93],"also":[96],"indicate":[97],"potential":[99],"of":[100],"controllers":[102],"as":[103],"practical":[104],"alternatives":[105],"controlling":[107],"nonlinear":[108],"complex":[110],"air-conditioning":[111],"systems.":[112]},"counts_by_year":[{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2025-11-06T04:12:42.849631","created_date":"2020-05-29T00:00:00"}
