{"id":"https://openalex.org/W3017541982","doi":"https://doi.org/10.35784/bud-arch.1555","title":"The impact of temperature, humidity and the direction of analysis on thermal conductivity \u03bb in different types of wood","display_name":"The impact of temperature, humidity and the direction of analysis on thermal conductivity \u03bb in different types of wood","alternate_titles":[],"publication_year":2015,"publication_date":"2015-12-08","ids":{"openalex":"https://openalex.org/W3017541982","doi":"https://doi.org/10.35784/bud-arch.1555","mag":"3017541982"},"language":"en","primary_location":{"id":"doi:10.35784/bud-arch.1555","doi":"https://doi.org/10.35784/bud-arch.1555","is_oa":true,"landing_page_url":"https://doi.org/10.35784/bud-arch.1555","pdf_url":"https://ph.pollub.pl/index.php/bia/article/download/1555/1306","source":{"id":"https://openalex.org/S4210201556","display_name":"Budownictwo i Architektura","issn_l":"2544-3275","issn":["2544-3275","1899-0665"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["ddh","doaj","erih-plus","norway-1","poland-40"],"host_organization":"https://openalex.org/P4310317259","host_organization_name":"Lublin University of Technology","host_organization_lineage":["https://openalex.org/P4310317259"],"host_organization_lineage_names":["Lublin University of Technology"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Budownictwo i Architektura","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W3017541982"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://ph.pollub.pl/index.php/bia/article/download/1555/1306","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5082096947","display_name":"Maciej Trochonowicz","type":null,"orcid":"https://orcid.org/0000-0001-7742-7916","observed_orcids":["https://orcid.org/0000-0001-7742-7916"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I8264552","display_name":"Lublin University of Technology","ror":"https://ror.org/024zjzd49","country_code":"PL","type":"education","lineage":["https://openalex.org/I8264552"]}],"countries":["PL"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Maciej Trochonowicz","raw_affiliation_strings":["Department of Conservation of Built Heritage; Faculty of Civil Engineering and Architecture; Lublin University of Technology","Department of Conservation of Built Heritage","Faculty of Civil Engineering and Architecture","Lublin University of Technology"],"raw_orcid":"https://orcid.org/0000-0001-7742-7916","affiliations":[{"raw_affiliation_string":"Department of Conservation of Built Heritage; Faculty of Civil Engineering and Architecture; Lublin University of Technology","institution_ids":["https://openalex.org/I8264552"]},{"raw_affiliation_string":"Department of Conservation of Built Heritage","institution_ids":[]},{"raw_affiliation_string":"Faculty of Civil Engineering and Architecture","institution_ids":[]},{"raw_affiliation_string":"Lublin University of Technology","institution_ids":["https://openalex.org/I8264552"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5045988701","display_name":"Nina Ko\u0142odziejczuk","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I8264552","display_name":"Lublin University of Technology","ror":"https://ror.org/024zjzd49","country_code":"PL","type":"education","lineage":["https://openalex.org/I8264552"]}],"countries":["PL"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Nina Ko\u0142odziejczuk","raw_affiliation_strings":["Department of Conservation of Built Heritage; Faculty of Civil Engineering and Architecture; Lublin University of Technology","Department of Conservation of Built Heritage","Faculty of Civil Engineering and Architecture","Lublin University of Technology"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Conservation of Built Heritage; Faculty of Civil Engineering and Architecture; Lublin University of Technology","institution_ids":["https://openalex.org/I8264552"]},{"raw_affiliation_string":"Department of Conservation of Built Heritage","institution_ids":[]},{"raw_affiliation_string":"Faculty of Civil Engineering and Architecture","institution_ids":[]},{"raw_affiliation_string":"Lublin University of Technology","institution_ids":["https://openalex.org/I8264552"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I8264552"],"apc_list":null,"apc_paid":null,"fwci":0.3496,"has_fulltext":true,"cited_by_count":2,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.65475746,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":92},"biblio":{"volume":"14","issue":"4","first_page":"149","last_page":"156"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12105","display_name":"Hygrothermal properties of building materials","score":0.5971999764442444,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12105","display_name":"Hygrothermal properties of building materials","score":0.5971999764442444,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10484","display_name":"Wood Treatment and Properties","score":0.29809999465942383,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.08950000256299973,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/thermal-conductivity","display_name":"thermal conductivity","score":0.8330000042915344},{"id":"https://openalex.org/keywords/wood","display_name":"wood","score":0.9909999966621399},{"id":"https://openalex.org/keywords/temperature-effects","display_name":"temperature effects","score":0.7279999852180481},{"id":"https://openalex.org/keywords/humidity","display_name":"humidity","score":0.8790000081062317},{"id":"https://openalex.org/keywords/moisture-content","display_name":"moisture content","score":0.6759999990463257},{"id":"https://openalex.org/keywords/anisotropy","display_name":"anisotropy","score":0.7979999780654907},{"id":"https://openalex.org/keywords/wood-density","display_name":"wood density","score":0.6700000166893005},{"id":"https://openalex.org/keywords/building-structures","display_name":"building structures","score":0.5920000076293945},{"id":"https://openalex.org/keywords/wooden-elements","display_name":"wooden elements","score":0.4000000059604645}],"concepts":[{"id":"https://openalex.org/C97346530","wikidata":"https://www.wikidata.org/wiki/Q487005","display_name":"Thermal conductivity","level":2,"score":0.7778381109237671},{"id":"https://openalex.org/C151420433","wikidata":"https://www.wikidata.org/wiki/Q180600","display_name":"Humidity","level":2,"score":0.7070035934448242},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5602462887763977},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.5105024576187134},{"id":"https://openalex.org/C158960510","wikidata":"https://www.wikidata.org/wiki/Q180600","display_name":"Relative humidity","level":2,"score":0.500272274017334},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.45915713906288147},{"id":"https://openalex.org/C131540310","wikidata":"https://www.wikidata.org/wiki/Q907564","display_name":"Conductivity","level":2,"score":0.42623740434646606},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.425787091255188},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.19448521733283997},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.12397459149360657},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10616034269332886},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.35784/bud-arch.1555","doi":"https://doi.org/10.35784/bud-arch.1555","is_oa":true,"landing_page_url":"https://doi.org/10.35784/bud-arch.1555","pdf_url":"https://ph.pollub.pl/index.php/bia/article/download/1555/1306","source":{"id":"https://openalex.org/S4210201556","display_name":"Budownictwo i Architektura","issn_l":"2544-3275","issn":["2544-3275","1899-0665"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["ddh","doaj","erih-plus","norway-1","poland-40"],"host_organization":"https://openalex.org/P4310317259","host_organization_name":"Lublin University of Technology","host_organization_lineage":["https://openalex.org/P4310317259"],"host_organization_lineage_names":["Lublin University of Technology"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Budownictwo i Architektura","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:bda0f545aab44a1b9622d7979af79722","doi":null,"is_oa":false,"landing_page_url":"https://doaj.org/article/bda0f545aab44a1b9622d7979af79722","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Budownictwo i Architektura, Vol 14, Iss 4 (2015)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.35784/bud-arch.1555","doi":"https://doi.org/10.35784/bud-arch.1555","is_oa":true,"landing_page_url":"https://doi.org/10.35784/bud-arch.1555","pdf_url":"https://ph.pollub.pl/index.php/bia/article/download/1555/1306","source":{"id":"https://openalex.org/S4210201556","display_name":"Budownictwo i Architektura","issn_l":"2544-3275","issn":["2544-3275","1899-0665"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["ddh","doaj","erih-plus","norway-1","poland-40"],"host_organization":"https://openalex.org/P4310317259","host_organization_name":"Lublin University of Technology","host_organization_lineage":["https://openalex.org/P4310317259"],"host_organization_lineage_names":["Lublin University of Technology"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Budownictwo i Architektura","raw_type":"journal-article"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3017541982.pdf","grobid_xml":"https://content.openalex.org/works/W3017541982.grobid-xml"},"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W3040193636","https://openalex.org/W4323926793","https://openalex.org/W4382141069","https://openalex.org/W2312846790","https://openalex.org/W1591718789","https://openalex.org/W7116799010","https://openalex.org/W4409798621","https://openalex.org/W3088031258","https://openalex.org/W1263381622","https://openalex.org/W2780985773"],"abstract_inverted_index":{"The":[0],"main":[1],"aim":[2],"of":[3,15,26,39,46,49,53],"the":[4,9,13,37,44,47],"article":[5],"is":[6],"to":[7,12],"present":[8,36],"issues":[10],"related":[11],"impact":[14,45],"temperature":[16],"and":[17,51],"humidity":[18],"on":[19,55],"thermal":[20,56],"conductivity":[21,57],"\uf06c":[22,58],"in":[23,29,59],"different":[24],"types":[25],"wood":[27,54],"used":[28],"building":[30],"structure.":[31],"In":[32],"this":[33],"elaboration":[34],"authors":[35],"results":[38],"laboratory":[40],"test.":[41],"Authors":[42],"checked":[43],"direction":[48],"analysis":[50],"density":[52],"wooden":[60],"elements.":[61]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W3017541982","counts_by_year":[{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1}],"updated_date":"2026-11-22T12:46:00.618207","created_date":"2020-05-01T00:00:00"}
