{"id":"https://openalex.org/W3013847079","doi":"https://doi.org/10.1016/j.anucene.2020.107467","title":"Dynamic reliability framework for a Nuclear Power Plant using dynamic flowgraph methodology","display_name":"Dynamic reliability framework for a Nuclear Power Plant using dynamic flowgraph methodology","publication_year":2020,"publication_date":"2020-03-24","ids":{"openalex":"https://openalex.org/W3013847079","doi":"https://doi.org/10.1016/j.anucene.2020.107467","mag":"3013847079"},"language":"en","primary_location":{"id":"doi:10.1016/j.anucene.2020.107467","doi":"https://doi.org/10.1016/j.anucene.2020.107467","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.anucene.2020.107467","pdf_url":null,"source":{"id":"https://openalex.org/S197743716","display_name":"Annals of Nuclear Energy","issn_l":"0306-4549","issn":["0306-4549","1873-2100"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-1","norway-1","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annals of Nuclear Energy","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101833381","display_name":"Manish Tripathi","orcid":"https://orcid.org/0000-0003-3449-9324","observed_orcids":["https://orcid.org/0000-0003-3449-9324"]},"institutions":[{"id":"https://openalex.org/I162827531","display_name":"Indian Institute of Technology Bombay","ror":"https://ror.org/02qyf5152","country_code":"IN","type":"education","lineage":["https://openalex.org/I162827531"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Manish Tripathi","raw_affiliation_strings":["Department of Energy Science & Engineering, IIT Bombay, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Energy Science & Engineering, IIT Bombay, India","institution_ids":["https://openalex.org/I162827531"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043500933","display_name":"Lalit Kumar Singh","orcid":"https://orcid.org/0000-0003-0375-3414","observed_orcids":["https://orcid.org/0000-0003-0375-3414"]},"institutions":[{"id":"https://openalex.org/I56404289","display_name":"Indian Institute of Technology BHU","ror":"https://ror.org/01kh5gc44","country_code":"IN","type":"education","lineage":["https://openalex.org/I56404289","https://openalex.org/I91357014"]},{"id":"https://openalex.org/I91357014","display_name":"Banaras Hindu University","ror":"https://ror.org/04cdn2797","country_code":"IN","type":"education","lineage":["https://openalex.org/I91357014"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Lalit Kumar Singh","raw_affiliation_strings":["Department of Computer Science & Engineering, IIT (BHU), Varanasi, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Computer Science & Engineering, IIT (BHU), Varanasi, India","institution_ids":["https://openalex.org/I56404289","https://openalex.org/I91357014"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5061754711","display_name":"Suneet Singh","orcid":"https://orcid.org/0000-0003-4572-9332","observed_orcids":["https://orcid.org/0000-0003-4572-9332"]},"institutions":[{"id":"https://openalex.org/I162827531","display_name":"Indian Institute of Technology Bombay","ror":"https://ror.org/02qyf5152","country_code":"IN","type":"education","lineage":["https://openalex.org/I162827531"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Suneet Singh","raw_affiliation_strings":["Department of Energy Science & Engineering, IIT Bombay, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Energy Science & Engineering, IIT Bombay, India","institution_ids":["https://openalex.org/I162827531"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5101833381"],"corresponding_institution_ids":["https://openalex.org/I162827531"],"apc_list":{"value":2100,"currency":"USD","value_usd":2100},"apc_paid":null,"fwci":0.9149,"has_fulltext":false,"cited_by_count":10,"citation_normalized_percentile":{"value":0.76502426,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"143","issue":null,"first_page":"107467","last_page":"107467"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.9603999853134155,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},"topics":[{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.9603999853134155,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T12560","display_name":"Nuclear Engineering Thermal-Hydraulics","score":0.022099999710917473,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.006500000134110451,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/dynamic-reliability","display_name":"dynamic reliability","score":0.7480000257492065},{"id":"https://openalex.org/keywords/nuclear-power-plants","display_name":"nuclear power plants","score":0.7829999923706055},{"id":"https://openalex.org/keywords/station-blackout","display_name":"station blackout","score":0.7940000295639038},{"id":"https://openalex.org/keywords/passive-safety-systems","display_name":"passive safety systems","score":0.902999997138977},{"id":"https://openalex.org/keywords/passive-decay-heat-removal","display_name":"passive decay heat removal","score":0.8930000066757202},{"id":"https://openalex.org/keywords/pressurized-heavy-water-reactor","display_name":"pressurized heavy water reactor","score":0.9620000123977661},{"id":"https://openalex.org/keywords/decay-heat-removal","display_name":"decay heat removal","score":0.6399999856948853},{"id":"https://openalex.org/keywords/safety-assessment","display_name":"safety assessment","score":0.5709999799728394}],"concepts":[{"id":"https://openalex.org/C107094494","wikidata":"https://www.wikidata.org/wiki/Q428453","display_name":"Fault tree analysis","level":2,"score":0.8280192613601685},{"id":"https://openalex.org/C18074226","wikidata":"https://www.wikidata.org/wiki/Q7310986","display_name":"Reliability block diagram","level":3,"score":0.8213258981704712},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.7838127017021179},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7338098287582397},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.6380740404129028},{"id":"https://openalex.org/C55439883","wikidata":"https://www.wikidata.org/wiki/Q360812","display_name":"Correctness","level":2,"score":0.6043345928192139},{"id":"https://openalex.org/C2777693866","wikidata":"https://www.wikidata.org/wiki/Q359099","display_name":"Blackout","level":4,"score":0.5560391545295715},{"id":"https://openalex.org/C66283442","wikidata":"https://www.wikidata.org/wiki/Q1389268","display_name":"Failure mode and effects analysis","level":2,"score":0.5361383557319641},{"id":"https://openalex.org/C2779979336","wikidata":"https://www.wikidata.org/wiki/Q134447","display_name":"Nuclear power plant","level":2,"score":0.5214670896530151},{"id":"https://openalex.org/C513653683","wikidata":"https://www.wikidata.org/wiki/Q12739","display_name":"Nuclear power","level":2,"score":0.4806584119796753},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.441432923078537},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.41490209102630615},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.40482014417648315},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2757321000099182},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.14141377806663513},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.0950222909450531},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C185544564","wikidata":"https://www.wikidata.org/wiki/Q81197","display_name":"Nuclear physics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1016/j.anucene.2020.107467","doi":"https://doi.org/10.1016/j.anucene.2020.107467","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.anucene.2020.107467","pdf_url":null,"source":{"id":"https://openalex.org/S197743716","display_name":"Annals of Nuclear Energy","issn_l":"0306-4549","issn":["0306-4549","1873-2100"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-1","norway-1","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annals of Nuclear Energy","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":27,"referenced_works":["https://openalex.org/W87453288","https://openalex.org/W1492134992","https://openalex.org/W1523452487","https://openalex.org/W1966769298","https://openalex.org/W1997683471","https://openalex.org/W2015406459","https://openalex.org/W2023086051","https://openalex.org/W2034002093","https://openalex.org/W2035957848","https://openalex.org/W2037400153","https://openalex.org/W2044212874","https://openalex.org/W2044436476","https://openalex.org/W2070098714","https://openalex.org/W2075190945","https://openalex.org/W2079154298","https://openalex.org/W2096395465","https://openalex.org/W2138075901","https://openalex.org/W2150977842","https://openalex.org/W2152373297","https://openalex.org/W2199152955","https://openalex.org/W2285762765","https://openalex.org/W2580494042","https://openalex.org/W2591680609","https://openalex.org/W2799641085","https://openalex.org/W2800466901","https://openalex.org/W2982685541","https://openalex.org/W6631174867"],"related_works":["https://openalex.org/W3199845346","https://openalex.org/W2982685541","https://openalex.org/W2364372745","https://openalex.org/W2734007493","https://openalex.org/W4386275740","https://openalex.org/W2963777397","https://openalex.org/W3203255405","https://openalex.org/W2998304845","https://openalex.org/W3191251994","https://openalex.org/W1989429001"],"abstract_inverted_index":null,"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":1}],"updated_date":"2026-10-16T09:59:22.235173","created_date":"2020-04-03T00:00:00"}