{"id":"https://openalex.org/W3003165690","doi":"https://doi.org/10.1109/pesgm40551.2019.8973574","title":"Investigation of Fault Ride-Through Capability of Hybrid VSC-LCC Multi-Terminal HVDC Transmission Systems","display_name":"Investigation of Fault Ride-Through Capability of Hybrid VSC-LCC Multi-Terminal HVDC Transmission Systems","publication_year":2019,"publication_date":"2019-08-01","ids":{"openalex":"https://openalex.org/W3003165690","doi":"https://doi.org/10.1109/pesgm40551.2019.8973574","mag":"3003165690"},"language":"en","primary_location":{"id":"doi:10.1109/pesgm40551.2019.8973574","doi":"https://doi.org/10.1109/pesgm40551.2019.8973574","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pesgm40551.2019.8973574","pdf_url":null,"source":{"id":"https://openalex.org/S4210212590","display_name":"IEEE Power Engineering Society General Meeting","issn_l":"1932-5517","issn":["1932-5517","2693-7891"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE Power &amp; Energy Society General Meeting (PESGM)","raw_type":"proceedings-article"},"volume":null,"type":"conference-abstract","is_traditional":false,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5082306853","display_name":"Naushath M. Haleem","orcid":"https://orcid.org/0000-0002-4193-6572","observed_orcids":["https://orcid.org/0000-0002-4193-6572"]},"institutions":[{"id":"https://openalex.org/I46247651","display_name":"University of Manitoba","ror":"https://ror.org/02gfys938","country_code":"CA","type":"education","lineage":["https://openalex.org/I46247651"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Naushath Mohamed Haleem","raw_affiliation_strings":["Electrical and Computer Engineering, University of Manitoba"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical and Computer Engineering, University of Manitoba","institution_ids":["https://openalex.org/I46247651"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003602426","display_name":"Athula D Rajapkse","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I46247651","display_name":"University of Manitoba","ror":"https://ror.org/02gfys938","country_code":"CA","type":"education","lineage":["https://openalex.org/I46247651"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Athula D Rajapkse","raw_affiliation_strings":["Electrical and Computer Engineering, University of Manitoba"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical and Computer Engineering, University of Manitoba","institution_ids":["https://openalex.org/I46247651"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007967662","display_name":"A.M. Gole","orcid":"https://orcid.org/0009-0002-6794-7373","observed_orcids":["https://orcid.org/0009-0002-6794-7373"]},"institutions":[{"id":"https://openalex.org/I46247651","display_name":"University of Manitoba","ror":"https://ror.org/02gfys938","country_code":"CA","type":"education","lineage":["https://openalex.org/I46247651"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Aniruddha M. Gole","raw_affiliation_strings":["Electrical and Computer Engineering, University of Manitoba"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical and Computer Engineering, University of Manitoba","institution_ids":["https://openalex.org/I46247651"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5103151905","display_name":"Ioni T. Fernando","orcid":"https://orcid.org/0000-0003-4400-441X","observed_orcids":["https://orcid.org/0000-0003-4400-441X"]},"institutions":[{"id":"https://openalex.org/I33814908","display_name":"Manitoba Hydro","ror":"https://ror.org/03y90jx90","country_code":"CA","type":"company","lineage":["https://openalex.org/I33814908"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Ioni T. Fernando","raw_affiliation_strings":["System Planning, Manitoba Hydro"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"System Planning, Manitoba Hydro","institution_ids":["https://openalex.org/I33814908"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":10,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"1"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-ride-through","display_name":"fault ride-through","score":0.9129999876022339},{"id":"https://openalex.org/keywords/hybrid-hvdc","display_name":"hybrid HVDC","score":0.7950000166893005},{"id":"https://openalex.org/keywords/multiterminal-hvdc","display_name":"multi-terminal HVDC","score":0.9399999976158142},{"id":"https://openalex.org/keywords/line-commutated-converter","display_name":"line commutated converter","score":0.906000018119812},{"id":"https://openalex.org/keywords/voltage-source-converter","display_name":"voltage source converter","score":0.9919999837875366},{"id":"https://openalex.org/keywords/half-bridge-modular-multilevel-converter","display_name":"half-bridge modular multilevel converter","score":0.949999988079071},{"id":"https://openalex.org/keywords/ac-circuit-breakers","display_name":"AC circuit breakers","score":0.8169999718666077},{"id":"https://openalex.org/keywords/arc-extinction","display_name":"arc interruption","score":0.6890000104904175},{"id":"https://openalex.org/keywords/hvdc-transmission","display_name":"HVDC transmission","score":0.49399998784065247}],"concepts":[{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.7163767218589783},{"id":"https://openalex.org/C50100734","wikidata":"https://www.wikidata.org/wiki/Q7303176","display_name":"Rectifier (neural networks)","level":5,"score":0.7119517922401428},{"id":"https://openalex.org/C144655898","wikidata":"https://www.wikidata.org/wiki/Q1161128","display_name":"Voltage source","level":3,"score":0.6386935710906982},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6291557550430298},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.5682433843612671},{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.5307279229164124},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.4833614230155945},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4512844681739807},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.4346686899662018},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4265151917934418},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.42064887285232544},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4037652015686035},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.34289056062698364},{"id":"https://openalex.org/C2776620479","wikidata":"https://www.wikidata.org/wiki/Q159241","display_name":"Direct current","level":3,"score":0.28416961431503296},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0},{"id":"https://openalex.org/C147168706","wikidata":"https://www.wikidata.org/wiki/Q1457734","display_name":"Recurrent neural network","level":3,"score":0.0},{"id":"https://openalex.org/C86582703","wikidata":"https://www.wikidata.org/wiki/Q7617824","display_name":"Stochastic neural network","level":4,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/pesgm40551.2019.8973574","doi":"https://doi.org/10.1109/pesgm40551.2019.8973574","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pesgm40551.2019.8973574","pdf_url":null,"source":{"id":"https://openalex.org/S4210212590","display_name":"IEEE Power Engineering Society General Meeting","issn_l":"1932-5517","issn":["1932-5517","2693-7891"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE Power &amp; Energy Society General Meeting (PESGM)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.5690000057220459},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.5378999710083008}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W3023243194","https://openalex.org/W3162514503","https://openalex.org/W3006305445","https://openalex.org/W2588673882","https://openalex.org/W3041991098","https://openalex.org/W2972334623","https://openalex.org/W2028798135","https://openalex.org/W2771062732","https://openalex.org/W4390416676","https://openalex.org/W3094011211"],"abstract_inverted_index":{"In":[0,131],"this":[1,44],"paper,":[2],"clearing":[3],"of":[4,15,49,61,159,162,183],"DC":[5,76],"faults":[6],"in":[7],"a":[8,52,62,81,135,157,172],"hybrid":[9,37],"multi-terminal":[10],"HVDC":[11,38],"transmission":[12,59,137],"system":[13,39],"consisting":[14],"line":[16,60,138],"commutated":[17],"converters":[18,23],"(LCCs)":[19],"and":[20,65,107,144,164],"voltage":[21,168],"source":[22],"(VSCs)":[24],"implemented":[25],"using":[26],"half-bridge":[27,53,71],"modular":[28],"multilevel":[29],"converter":[30],"(MMC)":[31],"technology":[32],"is":[33,139,150],"investigated.":[34],"While":[35],"the":[36,58,102,116,126,132,142,147,165,180],"has":[40],"several":[41],"possible":[42],"configurations,":[43],"paper":[45],"focuses":[46],"on":[47,57,179],"two":[48],"them:":[50],"1)":[51],"MMC-HVDC":[54],"link":[55,64,68],"piggy-backing":[56],"LCC-HVDC":[63,67],"2)":[66],"tapped":[69],"by":[70,141],"MMC":[72],"inverters.":[73],"The":[74],"proposed":[75,127],"fault":[77,95,122,128],"recovery":[78,123,129],"strategy":[79],"employs":[80],"high":[82,154],"rating":[83],"series":[84],"diode":[85],"valve":[86],"placed":[87],"at":[88,111],"each":[89],"VSC":[90,104,145,148,184],"inverter":[91],"pole":[92,174,182],"to":[93,100,114,152,189],"block":[94],"currents;":[96],"AC":[97,166],"circuit":[98],"breakers":[99],"isolate":[101],"faulty":[103],"rectifier":[105,113,149,185],"pole;":[106],"force":[108],"retardation":[109],"applied":[110],"LCC":[112,143],"extinguish":[115],"arc.":[117],"Detailed":[118],"simulations":[119],"demonstrate":[120],"fast":[121],"performance":[124],"with":[125],"procedure.":[130],"case":[133],"where":[134],"single":[136,173],"shared":[140],"links,":[146],"subjected":[151],"considerably":[153],"current":[155],"for":[156],"period":[158],"few":[160],"hundreds":[161],"milliseconds,":[163],"side":[167],"dips":[169],"momentarily.":[170],"During":[171],"fault,":[175],"interrupting":[176],"power":[177],"flow":[178],"healthy":[181],"may":[186],"be":[187],"necessary":[188],"maintain":[190],"smooth":[191],"operation.":[192]},"counts_by_year":[{"year":2024,"cited_by_count":3},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":1}],"updated_date":"2026-11-06T12:05:46.655746","created_date":"2020-02-07T00:00:00"}