{"id":"https://openalex.org/W2995099196","doi":"https://doi.org/10.1109/iecon.2019.8927634","title":"Impedance-based Stability Analysis for HVDC Diode-Rectifier Connected Off-shore Wind Farms","display_name":"Impedance-based Stability Analysis for HVDC Diode-Rectifier Connected Off-shore Wind Farms","publication_year":2019,"publication_date":"2019-10-01","ids":{"openalex":"https://openalex.org/W2995099196","doi":"https://doi.org/10.1109/iecon.2019.8927634","mag":"2995099196"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2019.8927634","doi":"https://doi.org/10.1109/iecon.2019.8927634","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8927634","pdf_url":null,"source":{"id":"https://openalex.org/S4210172894","display_name":"Annual Conference of the IEEE Industrial Electronics Society (IECON)","issn_l":"1553-572X","issn":["1553-572X","2577-1647"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://hdl.handle.net/10251/201067","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5037223921","display_name":"S. A\u00f1\u00f3-Villalba","orcid":"https://orcid.org/0000-0002-8435-5225","observed_orcids":["https://orcid.org/0000-0002-8435-5225"]},"institutions":[{"id":"https://openalex.org/I60053951","display_name":"Universitat Polit\u00e8cnica de Val\u00e8ncia","ror":"https://ror.org/01460j859","country_code":"ES","type":"education","lineage":["https://openalex.org/I60053951"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"S. Ano-Villalba","raw_affiliation_strings":["Universitat Polit\u00e8cnica de Val\u00e8ncia, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universitat Polit\u00e8cnica de Val\u00e8ncia, Spain","institution_ids":["https://openalex.org/I60053951"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000413447","display_name":"S. Bernal-Perez","orcid":"https://orcid.org/0000-0002-5431-9792","observed_orcids":["https://orcid.org/0000-0002-5431-9792"]},"institutions":[{"id":"https://openalex.org/I60053951","display_name":"Universitat Polit\u00e8cnica de Val\u00e8ncia","ror":"https://ror.org/01460j859","country_code":"ES","type":"education","lineage":["https://openalex.org/I60053951"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"S. Bernal-Perez","raw_affiliation_strings":["Universitat Polit\u00e8cnica de Val\u00e8ncia, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universitat Polit\u00e8cnica de Val\u00e8ncia, Spain","institution_ids":["https://openalex.org/I60053951"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5020082079","display_name":"Jaime Mart\u00ednez\u2010Tur\u00e9gano","orcid":"https://orcid.org/0000-0002-3483-8253","observed_orcids":["https://orcid.org/0000-0002-3483-8253"]},"institutions":[{"id":"https://openalex.org/I60053951","display_name":"Universitat Polit\u00e8cnica de Val\u00e8ncia","ror":"https://ror.org/01460j859","country_code":"ES","type":"education","lineage":["https://openalex.org/I60053951"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"J. Martinez-Turegano","raw_affiliation_strings":["Universitat Polit\u00e8cnica de Val\u00e8ncia, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universitat Polit\u00e8cnica de Val\u00e8ncia, Spain","institution_ids":["https://openalex.org/I60053951"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5029491797","display_name":"Ram\u00f3n Blasco-Gim\u00e9nez","orcid":"https://orcid.org/0000-0003-3427-1581","observed_orcids":["https://orcid.org/0000-0003-3427-1581"]},"institutions":[{"id":"https://openalex.org/I60053951","display_name":"Universitat Polit\u00e8cnica de Val\u00e8ncia","ror":"https://ror.org/01460j859","country_code":"ES","type":"education","lineage":["https://openalex.org/I60053951"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"R. Blasco-Gimenez","raw_affiliation_strings":["Universitat Polit\u00e8cnica de Val\u00e8ncia, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universitat Polit\u00e8cnica de Val\u00e8ncia, Spain","institution_ids":["https://openalex.org/I60053951"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I60053951"],"apc_list":null,"apc_paid":null,"fwci":0.3951,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.41034968,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"2389","last_page":"2394"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.8618000149726868,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.8618000149726868,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.09440000355243683,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.008899999782443047,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/impedance-based-stability-analysis","display_name":"impedance-based stability analysis","score":0.8799999952316284},{"id":"https://openalex.org/keywords/offshore-wind-farms","display_name":"offshore wind farms","score":0.9819999933242798},{"id":"https://openalex.org/keywords/grid-forming-inverters","display_name":"grid-forming inverters","score":0.7730000019073486},{"id":"https://openalex.org/keywords/frequency-dependent-impedance","display_name":"frequency-dependent impedance","score":0.9440000057220459},{"id":"https://openalex.org/keywords/signal-injection","display_name":"signal injection","score":0.824999988079071},{"id":"https://openalex.org/keywords/frequency-response-identification","display_name":"frequency response identification","score":0.5799999833106995},{"id":"https://openalex.org/keywords/power-system-stability","display_name":"power system stability","score":0.5929999947547913}],"concepts":[{"id":"https://openalex.org/C50100734","wikidata":"https://www.wikidata.org/wiki/Q7303176","display_name":"Rectifier (neural networks)","level":5,"score":0.686277449131012},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6633661389350891},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.6249250173568726},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.5818779468536377},{"id":"https://openalex.org/C46871319","wikidata":"https://www.wikidata.org/wiki/Q943122","display_name":"Precision rectifier","level":4,"score":0.5727720260620117},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.49767377972602844},{"id":"https://openalex.org/C8735168","wikidata":"https://www.wikidata.org/wiki/Q61637704","display_name":"Offshore wind power","level":3,"score":0.4940517246723175},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.46291452646255493},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4425423741340637},{"id":"https://openalex.org/C26262908","wikidata":"https://www.wikidata.org/wiki/Q1307489","display_name":"Input impedance","level":3,"score":0.4100510776042938},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.39076030254364014},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2896895110607147},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.14285492897033691},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.07522475719451904},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0659787654876709},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0},{"id":"https://openalex.org/C147168706","wikidata":"https://www.wikidata.org/wiki/Q1457734","display_name":"Recurrent neural network","level":3,"score":0.0},{"id":"https://openalex.org/C86582703","wikidata":"https://www.wikidata.org/wiki/Q7617824","display_name":"Stochastic neural network","level":4,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/iecon.2019.8927634","doi":"https://doi.org/10.1109/iecon.2019.8927634","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8927634","pdf_url":null,"source":{"id":"https://openalex.org/S4210172894","display_name":"Annual Conference of the IEEE Industrial Electronics Society (IECON)","issn_l":"1553-572X","issn":["1553-572X","2577-1647"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},{"id":"pmh:oai:riunet.upv.es:10251/201067","doi":null,"is_oa":true,"landing_page_url":"http://hdl.handle.net/10251/201067","pdf_url":null,"source":{"id":"https://openalex.org/S4306400639","display_name":"RiuNet (Universitat Polit\u00e8cnica de Val\u00e8ncia)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I60053951","host_organization_name":"Universitat Polit\u00e8cnica de Val\u00e8ncia","host_organization_lineage":["https://openalex.org/I60053951"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":{"id":"pmh:oai:riunet.upv.es:10251/201067","doi":null,"is_oa":true,"landing_page_url":"http://hdl.handle.net/10251/201067","pdf_url":null,"source":{"id":"https://openalex.org/S4306400639","display_name":"RiuNet (Universitat Polit\u00e8cnica de Val\u00e8ncia)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I60053951","host_organization_name":"Universitat Polit\u00e8cnica de Val\u00e8ncia","host_organization_lineage":["https://openalex.org/I60053951"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferenceObject"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.9853000044822693,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/9","score":0.6773999929428101,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W1994339148","https://openalex.org/W2017499404","https://openalex.org/W2059955282","https://openalex.org/W2063601737","https://openalex.org/W2071943147","https://openalex.org/W2073017797","https://openalex.org/W2093058113","https://openalex.org/W2094488685","https://openalex.org/W2103792123","https://openalex.org/W2115852741","https://openalex.org/W2148913139","https://openalex.org/W2150400373","https://openalex.org/W2310463642","https://openalex.org/W2551372897","https://openalex.org/W2944114219","https://openalex.org/W2950731159","https://openalex.org/W6940956031"],"related_works":["https://openalex.org/W3138528279","https://openalex.org/W3043633086","https://openalex.org/W2551372897","https://openalex.org/W2902996458","https://openalex.org/W2012797691","https://openalex.org/W2327006447","https://openalex.org/W2899465808","https://openalex.org/W4396904440","https://openalex.org/W4400645787","https://openalex.org/W2294540291"],"abstract_inverted_index":{"This":[0,74],"paper":[1,75],"includes":[2,76],"a":[3,7,63],"stability":[4,30,81,126,153],"study":[5],"of":[6,21,40,47,66,70,79,94,100,147,155],"HVDC":[8,55,84,104],"diode":[9,56,102],"rectifier":[10,57,103],"connected":[11,86,158],"off-shore":[12,87],"wind":[13,23,49,72,88,96,159],"power":[14,160],"plant.":[15],"Usually,":[16],"the":[17,44,67,71,77,95,101,125,129,140,145,148,152],"internal":[18],"control":[19,68],"strategy":[20],"commercial":[22],"turbines":[24],"are":[25,39,106],"not":[26],"completely":[27],"known,":[28],"so":[29],"studies":[31],"based":[32],"on":[33],"transfer":[34],"functions":[35],"or":[36],"eigenvalue":[37],"analysis":[38,82,127,154],"limited":[41],"use.":[42],"However,":[43],"frequency":[45,91,132],"behaviour":[46],"both":[48,108],"turbine":[50,97],"grid":[51],"side":[52],"converters":[53,98],"and":[54,99,115,134],"station":[58,105],"can":[59],"be":[60],"obtained":[61],"without":[62],"detailed":[64],"knowledge":[65],"internals":[69],"turbines.":[73],"validation":[78],"impedance-based":[80],"for":[83,151],"diode-rectfier":[85],"farms.":[89],"The":[90],"dependent":[92],"impedance":[93,131,149],"developed":[107],"analytically":[109],"from":[110,136],"their":[111],"respective":[112],"analytical":[113],"models":[114],"also":[116],"by":[117],"using":[118,128],"signal":[119],"injection.":[120],"It":[121],"is":[122],"shown":[123],"that":[124,135],"identified":[130],"response":[133],"analytic":[137],"calculation":[138],"lead":[139],"same":[141],"results,":[142],"thus":[143],"validating":[144],"use":[146],"method":[150],"grid-forming":[156],"Diode-rectifier":[157],"plants.":[161]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2019-12-26T00:00:00"}
