{"id":"https://openalex.org/W2991751027","doi":"https://doi.org/10.1109/tpel.2019.2957451","title":"A Novel Interleaved Nonisolated Bidirectional DC\u2013DC Converter With High Voltage-Gain and Full-Range ZVS","display_name":"A Novel Interleaved Nonisolated Bidirectional DC\u2013DC Converter With High Voltage-Gain and Full-Range ZVS","publication_year":2019,"publication_date":"2019-12-04","ids":{"openalex":"https://openalex.org/W2991751027","doi":"https://doi.org/10.1109/tpel.2019.2957451","mag":"2991751027"},"language":"en","primary_location":{"id":"doi:10.1109/tpel.2019.2957451","doi":"https://doi.org/10.1109/tpel.2019.2957451","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpel.2019.2957451","pdf_url":null,"source":{"id":"https://openalex.org/S29875816","display_name":"IEEE Transactions on Power Electronics","issn_l":"0885-8993","issn":["0885-8993","1941-0107"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-3","norway-2","poland-200","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Electronics","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5055336814","display_name":"Zhixing Yan","orcid":"https://orcid.org/0000-0003-1677-0408","observed_orcids":["https://orcid.org/0000-0003-1677-0408"]},"institutions":[{"id":"https://openalex.org/I90610280","display_name":"South China University of Technology","ror":"https://ror.org/0530pts50","country_code":"CN","type":"education","lineage":["https://openalex.org/I90610280"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhixing Yan","raw_affiliation_strings":["School of Electric Power, South China University of Technology, Guangzhou, China"],"raw_orcid":"https://orcid.org/0000-0003-1677-0408","affiliations":[{"raw_affiliation_string":"School of Electric Power, South China University of Technology, Guangzhou, China","institution_ids":["https://openalex.org/I90610280"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5062004910","display_name":"Jun Zeng","orcid":"https://orcid.org/0000-0002-5270-4814","observed_orcids":["https://orcid.org/0000-0002-5270-4814"]},"institutions":[{"id":"https://openalex.org/I90610280","display_name":"South China University of Technology","ror":"https://ror.org/0530pts50","country_code":"CN","type":"education","lineage":["https://openalex.org/I90610280"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jun Zeng","raw_affiliation_strings":["New Energy Research Center, South China University of Technology, Guangzhou, China"],"raw_orcid":"https://orcid.org/0000-0002-5270-4814","affiliations":[{"raw_affiliation_string":"New Energy Research Center, South China University of Technology, Guangzhou, China","institution_ids":["https://openalex.org/I90610280"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5063013510","display_name":"Weijie Lin","orcid":"https://orcid.org/0000-0002-1023-1772","observed_orcids":["https://orcid.org/0000-0002-1023-1772"]},"institutions":[{"id":"https://openalex.org/I90610280","display_name":"South China University of Technology","ror":"https://ror.org/0530pts50","country_code":"CN","type":"education","lineage":["https://openalex.org/I90610280"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Weijie Lin","raw_affiliation_strings":["School of Electric Power, South China University of Technology, Guangzhou, China"],"raw_orcid":"https://orcid.org/0000-0002-1023-1772","affiliations":[{"raw_affiliation_string":"School of Electric Power, South China University of Technology, Guangzhou, China","institution_ids":["https://openalex.org/I90610280"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5054756309","display_name":"Junfeng Liu","orcid":"https://orcid.org/0000-0001-5772-7372","observed_orcids":["https://orcid.org/0000-0001-5772-7372","https://orcid.org/0009-0006-8205-4564"]},"institutions":[{"id":"https://openalex.org/I90610280","display_name":"South China University of Technology","ror":"https://ror.org/0530pts50","country_code":"CN","type":"education","lineage":["https://openalex.org/I90610280"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Junfeng Liu","raw_affiliation_strings":["School of Automation Science and Engineering, South China University of Technology, Guangzhou, China"],"raw_orcid":"https://orcid.org/0000-0001-5772-7372","affiliations":[{"raw_affiliation_string":"School of Automation Science and Engineering, South China University of Technology, Guangzhou, China","institution_ids":["https://openalex.org/I90610280"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I90610280"],"apc_list":{"value":2045,"currency":"USD","value_usd":2045},"apc_paid":null,"fwci":2.5283,"has_fulltext":false,"cited_by_count":63,"citation_normalized_percentile":{"value":0.90070328,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":99},"biblio":{"volume":"35","issue":"7","first_page":"7191","last_page":"7203"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/bidirectional-dc-dc-converter","display_name":"bidirectional DC-DC converter","score":0.9369999766349792},{"id":"https://openalex.org/keywords/non-isolated-converter","display_name":"non-isolated converter","score":0.8730000257492065},{"id":"https://openalex.org/keywords/interleaved-converter","display_name":"interleaved converter","score":0.8410000205039978},{"id":"https://openalex.org/keywords/buck-boost-converter","display_name":"buck-boost converter","score":0.7699999809265137},{"id":"https://openalex.org/keywords/zero-voltage-switching","display_name":"zero-voltage switching","score":0.8899999856948853},{"id":"https://openalex.org/keywords/high-voltage-gain","display_name":"high voltage gain","score":0.8659999966621399},{"id":"https://openalex.org/keywords/energy-storage-systems","display_name":"energy storage systems","score":0.6579999923706055},{"id":"https://openalex.org/keywords/dc-microgrid","display_name":"DC microgrid","score":0.8410000205039978},{"id":"https://openalex.org/keywords/phase-shift-control","display_name":"phase shift control","score":0.8149999976158142},{"id":"https://openalex.org/keywords/circulating-current-suppression","display_name":"circulating current suppression","score":0.8410000205039978},{"id":"https://openalex.org/keywords/soft-switching","display_name":"soft switching","score":0.5249999761581421},{"id":"https://openalex.org/keywords/magnetic-core-saturation","display_name":"magnetic core saturation","score":0.5569999814033508}],"concepts":[{"id":"https://openalex.org/C144534570","wikidata":"https://www.wikidata.org/wiki/Q5325","display_name":"Inductor","level":3,"score":0.6449995636940002},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.582005500793457},{"id":"https://openalex.org/C2779599953","wikidata":"https://www.wikidata.org/wiki/Q1776117","display_name":"Ripple","level":3,"score":0.5708851218223572},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5497027039527893},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.4251108169555664},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.406551331281662},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.39126715064048767},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.36068540811538696},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.35971441864967346},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3527446389198303},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.25439319014549255},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.09031152725219727},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tpel.2019.2957451","doi":"https://doi.org/10.1109/tpel.2019.2957451","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpel.2019.2957451","pdf_url":null,"source":{"id":"https://openalex.org/S29875816","display_name":"IEEE Transactions on Power Electronics","issn_l":"0885-8993","issn":["0885-8993","1941-0107"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-3","norway-2","poland-200","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.9853000044822693,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/9","score":0.5378999710083008,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[{"id":"https://openalex.org/G1790777942","display_name":null,"funder_award_id":"51877085","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G2094422554","display_name":null,"funder_award_id":"2018A030313066","funder_id":"https://openalex.org/F4320321921","funder_display_name":"Natural Science Foundation of Guangdong Province"},{"id":"https://openalex.org/G2536927930","display_name":null,"funder_award_id":"61573155","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G883369132","display_name":null,"funder_award_id":"2018ZD50","funder_id":"https://openalex.org/F4320323059","funder_display_name":"South China University of Technology"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320321921","display_name":"Natural Science Foundation of Guangdong Province","ror":null},{"id":"https://openalex.org/F4320323059","display_name":"South China University of Technology","ror":"https://ror.org/0530pts50"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":33,"referenced_works":["https://openalex.org/W1550755341","https://openalex.org/W1994224159","https://openalex.org/W2001312628","https://openalex.org/W2074795077","https://openalex.org/W2101107901","https://openalex.org/W2103599619","https://openalex.org/W2110014245","https://openalex.org/W2117729580","https://openalex.org/W2144165861","https://openalex.org/W2144561565","https://openalex.org/W2146419443","https://openalex.org/W2153499767","https://openalex.org/W2158822584","https://openalex.org/W2163028797","https://openalex.org/W2169607864","https://openalex.org/W2205404527","https://openalex.org/W2295081357","https://openalex.org/W2324253114","https://openalex.org/W2401660472","https://openalex.org/W2410001354","https://openalex.org/W2473372248","https://openalex.org/W2557996688","https://openalex.org/W2593065393","https://openalex.org/W2740896507","https://openalex.org/W2741173782","https://openalex.org/W2741343947","https://openalex.org/W2744399630","https://openalex.org/W2751507538","https://openalex.org/W2765652361","https://openalex.org/W2771866158","https://openalex.org/W2801801177","https://openalex.org/W2802805378","https://openalex.org/W2946821773"],"related_works":["https://openalex.org/W3040427592","https://openalex.org/W3158857622","https://openalex.org/W2617270943","https://openalex.org/W2019791789","https://openalex.org/W2771866158","https://openalex.org/W2918009257","https://openalex.org/W2585426397","https://openalex.org/W3025463269","https://openalex.org/W3156290458","https://openalex.org/W2507661411"],"abstract_inverted_index":{"A":[0,31],"nonisolated":[1],"soft-switching":[2],"bidirectional":[3],"dc-dc":[4],"converter":[5],"(BDC)":[6],"with":[7,58],"interleaved":[8,39,76],"technique":[9],"and":[10,24,49,89,156,168,187],"built-in":[11],"transformer":[12],"(BT)":[13],"is":[14,35,78,117,132],"proposed":[15,126,160],"for":[16,63,134],"the":[17,20,59,82,86,99,106,121,125,129,135,150,159,185,188,193],"interface":[18],"between":[19,184],"energy":[21],"storage":[22],"system":[23],"dc":[25],"microgrid":[26],"bus":[27],"in":[28,85,142,164],"this":[29],"article.":[30],"T-type":[32],"neutral-point-clamped":[33],"circuit":[34],"integrated":[36],"into":[37],"an":[38],"conventional":[40],"buck-boost":[41],"BDC":[42],"to":[43,70,80,91,112,119,138],"obtain":[44],"a":[45,64,143,176],"high":[46],"voltage-gain":[47],"ratio":[48],"decrease":[50],"voltage":[51,93,145],"stresses":[52],"of":[53,98,124,158],"power":[54,122],"switches":[55],"effectively.":[56],"Compared":[57],"couple-inductor,":[60],"BT":[61,100],"allows":[62],"small":[65],"magnetic":[66],"core":[67],"size,":[68],"owing":[69],"its":[71],"inherent":[72],"saturation":[73],"avoidance.":[74],"The":[75,153,166,182],"structure":[77],"employed":[79],"reduce":[81,149],"current":[83,108],"ripple":[84],"low-voltage":[87],"side":[88],"helps":[90],"achieve":[92],"matching":[94],"on":[95,175],"both":[96],"sides":[97],"under":[101],"pulsewidth":[102],"modulation":[103],"control.":[104],"Thus,":[105],"circulating":[107],"can":[109,148],"be":[110],"lowered":[111],"improve":[113],"efficiency.":[114],"Phase-shift":[115],"control":[116],"adopted":[118],"regulate":[120],"flows":[123],"BT-BDC.":[127],"Moreover,":[128],"optimal":[130],"design":[131],"given":[133],"component":[136],"parameters":[137],"accomplish":[139],"zero-voltage":[140],"switching":[141,151],"wide":[144],"range,":[146],"which":[147],"losses.":[152],"operational":[154],"principles":[155],"characteristics":[157],"BT-BDC":[161],"are":[162],"presented":[163],"detail.":[165],"analysis":[167,186],"performance":[169],"have":[170],"been":[171],"fully":[172],"validated":[173],"experimentally":[174],"40-60":[177],"V/400":[178],"V":[179],"1-kW":[180],"prototype.":[181],"accordance":[183],"experimental":[189],"results":[190],"further":[191],"testifies":[192],"advantages.":[194]},"counts_by_year":[{"year":2026,"cited_by_count":6},{"year":2025,"cited_by_count":14},{"year":2024,"cited_by_count":9},{"year":2023,"cited_by_count":6},{"year":2022,"cited_by_count":12},{"year":2021,"cited_by_count":12},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":1}],"updated_date":"2026-09-24T07:57:37.273135","created_date":"2019-12-13T00:00:00"}