{"id":"https://openalex.org/W2966189255","doi":"https://doi.org/10.1016/j.enbuild.2020.110275","title":"Economic performance assessment of three renovated multi-family buildings with different HVAC systems","display_name":"Economic performance assessment of three renovated multi-family buildings with different HVAC systems","publication_year":2020,"publication_date":"2020-07-01","ids":{"openalex":"https://openalex.org/W2966189255","doi":"https://doi.org/10.1016/j.enbuild.2020.110275","mag":"2966189255"},"language":"en","primary_location":{"id":"doi:10.1016/j.enbuild.2020.110275","doi":"https://doi.org/10.1016/j.enbuild.2020.110275","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.enbuild.2020.110275","pdf_url":null,"source":{"id":"https://openalex.org/S6846437","display_name":"Energy and Buildings","issn_l":"0378-7788","issn":["0378-7788","1872-6178"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-3","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy and Buildings","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5019919893","display_name":"Alaa Khadra","orcid":"https://orcid.org/0000-0003-4401-6736","observed_orcids":["https://orcid.org/0000-0003-4401-6736"]},"institutions":[{"id":"https://openalex.org/I122274158","display_name":"Dalarna University","ror":"https://ror.org/000hdh770","country_code":"SE","type":"education","lineage":["https://openalex.org/I122274158"]},{"id":"https://openalex.org/I4210141702","display_name":"University of G\u00e4vle","ror":"https://ror.org/043fje207","country_code":"SE","type":"education","lineage":["https://openalex.org/I4210141702"]}],"countries":["SE"],"is_corresponding":true,"raw_author_name":"Alaa Khadra","raw_affiliation_strings":["Building Technology, Dalarna University, 791 88 Falun, Sweden","Department of Building, Energy and Environmental Engineering, G\u00e4vle University, G\u00e4vle 801 76, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Building Technology, Dalarna University, 791 88 Falun, Sweden","institution_ids":["https://openalex.org/I122274158"]},{"raw_affiliation_string":"Department of Building, Energy and Environmental Engineering, G\u00e4vle University, G\u00e4vle 801 76, Sweden","institution_ids":["https://openalex.org/I4210141702"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060568920","display_name":"M\u00e5rten Hugosson","orcid":"https://orcid.org/0000-0002-0173-4773","observed_orcids":["https://orcid.org/0000-0002-0173-4773"]},"institutions":[{"id":"https://openalex.org/I4210116649","display_name":"University of Inland Norway","ror":"https://ror.org/02dx4dc92","country_code":"NO","type":"education","lineage":["https://openalex.org/I4210116649"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"M\u00e5rten Hugosson","raw_affiliation_strings":["Department of Organisation, Leadership and Management, Innland Norway University of Applied Sciences, 2418 Elverum, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Organisation, Leadership and Management, Innland Norway University of Applied Sciences, 2418 Elverum, Norway","institution_ids":["https://openalex.org/I4210116649"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082183071","display_name":"Jan Akander","orcid":"https://orcid.org/0000-0001-9076-0801","observed_orcids":["https://orcid.org/0000-0001-9076-0801"]},"institutions":[{"id":"https://openalex.org/I4210141702","display_name":"University of G\u00e4vle","ror":"https://ror.org/043fje207","country_code":"SE","type":"education","lineage":["https://openalex.org/I4210141702"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Jan Akander","raw_affiliation_strings":["Department of Building, Energy and Environmental Engineering, G\u00e4vle University, G\u00e4vle 801 76, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Building, Energy and Environmental Engineering, G\u00e4vle University, G\u00e4vle 801 76, Sweden","institution_ids":["https://openalex.org/I4210141702"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5103208393","display_name":"Jonn Are Myhren","orcid":"https://orcid.org/0000-0002-9943-9878","observed_orcids":["https://orcid.org/0000-0002-9943-9878"]},"institutions":[{"id":"https://openalex.org/I122274158","display_name":"Dalarna University","ror":"https://ror.org/000hdh770","country_code":"SE","type":"education","lineage":["https://openalex.org/I122274158"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Jonn Are Myhren","raw_affiliation_strings":["Building Technology, Dalarna University, 791 88 Falun, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Building Technology, Dalarna University, 791 88 Falun, Sweden","institution_ids":["https://openalex.org/I122274158"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5019919893"],"corresponding_institution_ids":["https://openalex.org/I122274158","https://openalex.org/I4210141702"],"apc_list":{"value":3100,"currency":"USD","value_usd":3100},"apc_paid":null,"fwci":7.907,"has_fulltext":false,"cited_by_count":26,"citation_normalized_percentile":{"value":0.96973716,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"224","issue":null,"first_page":"110275","last_page":"110275"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14138","display_name":"Life Cycle Costing Analysis","score":0.6118000149726868,"subfield":{"id":"https://openalex.org/subfields/1402","display_name":"Accounting"},"field":{"id":"https://openalex.org/fields/14","display_name":"Business, Management and Accounting"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},"topics":[{"id":"https://openalex.org/T14138","display_name":"Life Cycle Costing Analysis","score":0.6118000149726868,"subfield":{"id":"https://openalex.org/subfields/1402","display_name":"Accounting"},"field":{"id":"https://openalex.org/fields/14","display_name":"Business, Management and Accounting"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.3677000105381012,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.01640000008046627,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/multifamily-housing","display_name":"multi-family housing","score":0.8069999814033508},{"id":"https://openalex.org/keywords/building-renovation","display_name":"building renovation","score":0.8109999895095825},{"id":"https://openalex.org/keywords/hvac-systems","display_name":"HVAC systems","score":0.8830000162124634},{"id":"https://openalex.org/keywords/heat-recovery-ventilation","display_name":"heat recovery ventilation","score":0.7990000247955322},{"id":"https://openalex.org/keywords/exhaust-ventilation","display_name":"exhaust ventilation","score":0.8709999918937683},{"id":"https://openalex.org/keywords/exhaust-air-heat-pump","display_name":"exhaust air heat pump","score":0.9509999752044678},{"id":"https://openalex.org/keywords/life-cycle-cost-analysis","display_name":"life cycle cost analysis","score":0.7919999957084656},{"id":"https://openalex.org/keywords/economic-performance","display_name":"economic performance","score":0.6779999732971191},{"id":"https://openalex.org/keywords/energy-efficiency","display_name":"energy efficiency","score":0.6259999871253967},{"id":"https://openalex.org/keywords/discount-rate","display_name":"discount rate","score":0.7110000252723694},{"id":"https://openalex.org/keywords/sensitivity-analysis","display_name":"sensitivity analysis","score":0.5820000171661377}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.7660217881202698},{"id":"https://openalex.org/C129361004","wikidata":"https://www.wikidata.org/wiki/Q2470236","display_name":"Profitability index","level":2,"score":0.5904045104980469},{"id":"https://openalex.org/C17005505","wikidata":"https://www.wikidata.org/wiki/Q11164636","display_name":"Energy recovery ventilation","level":4,"score":0.5842790603637695},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.5695644021034241},{"id":"https://openalex.org/C127145964","wikidata":"https://www.wikidata.org/wiki/Q2142051","display_name":"Heat recovery ventilation","level":3,"score":0.512012779712677},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4915667474269867},{"id":"https://openalex.org/C2778580826","wikidata":"https://www.wikidata.org/wiki/Q6545089","display_name":"Life-cycle cost analysis","level":2,"score":0.4524215757846832},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4469098150730133},{"id":"https://openalex.org/C19096712","wikidata":"https://www.wikidata.org/wiki/Q1307276","display_name":"Single-family detached home","level":2,"score":0.4232825040817261},{"id":"https://openalex.org/C2776461528","wikidata":"https://www.wikidata.org/wiki/Q131313","display_name":"Heat pump","level":3,"score":0.41273632645606995},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.40948665142059326},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3385205566883087},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.18954703211784363},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.18899807333946228},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.18595585227012634},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.1538105010986328},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.12886905670166016},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.08693286776542664},{"id":"https://openalex.org/C10138342","wikidata":"https://www.wikidata.org/wiki/Q43015","display_name":"Finance","level":1,"score":0.08107516169548035},{"id":"https://openalex.org/C166957645","wikidata":"https://www.wikidata.org/wiki/Q23498","display_name":"Archaeology","level":1,"score":0.0},{"id":"https://openalex.org/C95457728","wikidata":"https://www.wikidata.org/wiki/Q309","display_name":"History","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1016/j.enbuild.2020.110275","doi":"https://doi.org/10.1016/j.enbuild.2020.110275","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.enbuild.2020.110275","pdf_url":null,"source":{"id":"https://openalex.org/S6846437","display_name":"Energy and Buildings","issn_l":"0378-7788","issn":["0378-7788","1872-6178"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-3","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy and Buildings","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.878000020980835,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/13","score":0.75,"display_name":"Climate action"},{"id":"https://metadata.un.org/sdg/11","score":0.5142999887466431,"display_name":"Sustainable cities and communities"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320322711","display_name":"Energimyndigheten","ror":"https://ror.org/0359z7n90"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W792421993","https://openalex.org/W1490258766","https://openalex.org/W1965787573","https://openalex.org/W1987623173","https://openalex.org/W1995712682","https://openalex.org/W2010760613","https://openalex.org/W2045544978","https://openalex.org/W2055037959","https://openalex.org/W2076950582","https://openalex.org/W2161461039","https://openalex.org/W2182574114","https://openalex.org/W2216620675","https://openalex.org/W2216646115","https://openalex.org/W2340812556","https://openalex.org/W2403699066","https://openalex.org/W2537364585","https://openalex.org/W2568215667","https://openalex.org/W2714744148","https://openalex.org/W2784639579","https://openalex.org/W2801002854","https://openalex.org/W2954001409","https://openalex.org/W2965281447","https://openalex.org/W6907580124"],"related_works":["https://openalex.org/W6990611383","https://openalex.org/W7213555318","https://openalex.org/W7035844088","https://openalex.org/W1532932222","https://openalex.org/W4391542143","https://openalex.org/W2974229336","https://openalex.org/W1769253063","https://openalex.org/W1553978621","https://openalex.org/W7029696749","https://openalex.org/W2403699066"],"abstract_inverted_index":null,"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":7},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":5},{"year":2021,"cited_by_count":8}],"updated_date":"2026-10-16T09:59:22.235173","created_date":"2019-08-13T00:00:00"}
