{"id":"https://openalex.org/W2962724066","doi":"https://doi.org/10.1117/12.2524585","title":"Optical coherence tomography-based 3D intraoral scanner","display_name":"Optical coherence tomography-based 3D intraoral scanner","publication_year":2019,"publication_date":"2019-07-19","ids":{"openalex":"https://openalex.org/W2962724066","doi":"https://doi.org/10.1117/12.2524585","mag":"2962724066"},"language":"en","primary_location":{"id":"doi:10.1117/12.2524585","doi":"https://doi.org/10.1117/12.2524585","is_oa":false,"landing_page_url":"https://doi.org/10.1117/12.2524585","pdf_url":null,"source":{"id":"https://openalex.org/S7407105171","display_name":"Optical Coherence Imaging Techniques and Imaging in Scattering Media","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310315543","host_organization_name":"SPIE","host_organization_lineage":["https://openalex.org/P4310315543"],"host_organization_lineage_names":["SPIE"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Optical Coherence Imaging Techniques and Imaging in Scattering Media III","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5046978856","display_name":"Joo Beom Eom","orcid":"https://orcid.org/0000-0001-5133-8931","observed_orcids":["https://orcid.org/0000-0001-5133-8931"]},"institutions":[{"id":"https://openalex.org/I4210117738","display_name":"Korea Photonics Technology Institute","ror":"https://ror.org/022mx4d10","country_code":"KR","type":"facility","lineage":["https://openalex.org/I4210117738"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Joo Beom Eom","raw_affiliation_strings":["Medical photonics research center, Korea Photonics Technology Institute, 9 Cheomdan venture-ro 108 beon-gil, Buk-gu, Gwangju, 500-779, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Medical photonics research center, Korea Photonics Technology Institute, 9 Cheomdan venture-ro 108 beon-gil, Buk-gu, Gwangju, 500-779, South Korea","institution_ids":["https://openalex.org/I4210117738"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010062091","display_name":"Jonghyun Eom","orcid":"https://orcid.org/0000-0003-4499-0803","observed_orcids":["https://orcid.org/0000-0003-4499-0803"]},"institutions":[{"id":"https://openalex.org/I4210117738","display_name":"Korea Photonics Technology Institute","ror":"https://ror.org/022mx4d10","country_code":"KR","type":"facility","lineage":["https://openalex.org/I4210117738"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Jonghyun Eom","raw_affiliation_strings":["Medical photonics research center, Korea Photonics Technology Institute, 9 Cheomdan venture-ro 108 beon-gil, Buk-gu, Gwangju, 500-779, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Medical photonics research center, Korea Photonics Technology Institute, 9 Cheomdan venture-ro 108 beon-gil, Buk-gu, Gwangju, 500-779, South Korea","institution_ids":["https://openalex.org/I4210117738"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5070046165","display_name":"Anjin Park","orcid":"https://orcid.org/0000-0001-6707-1899","observed_orcids":["https://orcid.org/0000-0001-6707-1899"]},"institutions":[{"id":"https://openalex.org/I4210117738","display_name":"Korea Photonics Technology Institute","ror":"https://ror.org/022mx4d10","country_code":"KR","type":"facility","lineage":["https://openalex.org/I4210117738"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Anjin Park","raw_affiliation_strings":["Medical photonics research center, Korea Photonics Technology Institute, 9 Cheomdan venture-ro 108 beon-gil, Buk-gu, Gwangju, 500-779, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Medical photonics research center, Korea Photonics Technology Institute, 9 Cheomdan venture-ro 108 beon-gil, Buk-gu, Gwangju, 500-779, South Korea","institution_ids":["https://openalex.org/I4210117738"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5103214658","display_name":"Jin\u2010Chul Ahn","orcid":"https://orcid.org/0000-0002-0501-7210","observed_orcids":["https://orcid.org/0000-0002-0501-7210"]},"institutions":[{"id":"https://openalex.org/I89015989","display_name":"Dankook University","ror":"https://ror.org/058pdbn81","country_code":"KR","type":"education","lineage":["https://openalex.org/I89015989"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Jin-Chul Ahn","raw_affiliation_strings":["Department of Pre-medical Science, Dankook University, Cheonan 31116, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Pre-medical Science, Dankook University, Cheonan 31116, Republic of Korea","institution_ids":["https://openalex.org/I89015989"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4153,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.48574163,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":"5","issue":null,"first_page":"74","last_page":"74"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11569","display_name":"Optical Coherence Tomography Applications","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11569","display_name":"Optical Coherence Tomography Applications","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11363","display_name":"Dental Radiography and Imaging","score":0.0,"subfield":{"id":"https://openalex.org/subfields/3504","display_name":"Oral Surgery"},"field":{"id":"https://openalex.org/fields/35","display_name":"Dentistry"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10638","display_name":"Optical measurement and interference techniques","score":0.0,"subfield":{"id":"https://openalex.org/subfields/1707","display_name":"Computer Vision and Pattern Recognition"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/optical-coherence-tomography","display_name":"optical coherence tomography","score":0.9440000057220459},{"id":"https://openalex.org/keywords/swept-source-oct","display_name":"swept-source optical coherence tomography","score":0.8199999928474426},{"id":"https://openalex.org/keywords/intraoral-scanners","display_name":"intraoral scanners","score":0.8109999895095825},{"id":"https://openalex.org/keywords/mems-micromirror","display_name":"MEMS mirror","score":0.8220000267028809},{"id":"https://openalex.org/keywords/iterative-closest-point","display_name":"iterative closest point","score":0.6700000166893005},{"id":"https://openalex.org/keywords/image-stitching","display_name":"image stitching","score":0.6240000128746033},{"id":"https://openalex.org/keywords/dental-imaging","display_name":"dental imaging","score":0.5910000205039978}],"concepts":[{"id":"https://openalex.org/C2778818243","wikidata":"https://www.wikidata.org/wiki/Q899552","display_name":"Optical coherence tomography","level":2,"score":0.8602996468544006},{"id":"https://openalex.org/C2779751349","wikidata":"https://www.wikidata.org/wiki/Q1474480","display_name":"Scanner","level":2,"score":0.7409783601760864},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5256437063217163},{"id":"https://openalex.org/C2777413408","wikidata":"https://www.wikidata.org/wiki/Q1968843","display_name":"Optical tomography","level":3,"score":0.5083312392234802},{"id":"https://openalex.org/C163716698","wikidata":"https://www.wikidata.org/wiki/Q841267","display_name":"Tomography","level":2,"score":0.4914332628250122},{"id":"https://openalex.org/C2781181686","wikidata":"https://www.wikidata.org/wiki/Q4226068","display_name":"Coherence (philosophical gambling strategy)","level":2,"score":0.44417837262153625},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.3908270597457886},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.3629641532897949},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.2802303433418274},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1752062439918518},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1117/12.2524585","doi":"https://doi.org/10.1117/12.2524585","is_oa":false,"landing_page_url":"https://doi.org/10.1117/12.2524585","pdf_url":null,"source":{"id":"https://openalex.org/S7407105171","display_name":"Optical Coherence Imaging Techniques and Imaging in Scattering Media","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310315543","host_organization_name":"SPIE","host_organization_lineage":["https://openalex.org/P4310315543"],"host_organization_lineage_names":["SPIE"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Optical Coherence Imaging Techniques and Imaging in Scattering Media III","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5683000087738037,"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2008204574","https://openalex.org/W2043860371","https://openalex.org/W2049981393","https://openalex.org/W2951061800"],"related_works":["https://openalex.org/W2951061800","https://openalex.org/W4391246788","https://openalex.org/W4391176637","https://openalex.org/W4385725445","https://openalex.org/W7124446418","https://openalex.org/W2003701850","https://openalex.org/W2372108613","https://openalex.org/W2956580498","https://openalex.org/W2023887159","https://openalex.org/W2060767402"],"abstract_inverted_index":{"We":[0],"report":[1],"fabrication":[2],"and":[3,23,61,116,121,152,165,181],"performance":[4],"of":[5,21,25,51,74,79,88,103,123,129,171,184],"the":[6,26,36,45,54,89,104,111,124,138,145,156,169,179,185],"three-dimensional":[7,18],"intraoral":[8,94,157,172,189],"scanner":[9,55,70,95,158,190],"based":[10,43,67,96,159],"on":[11,44,68,97,160],"optical":[12,62],"coherence":[13],"tomography":[14],"(OCT)":[15],"that":[16,41,174],"enables":[17],"structure":[19,122,180],"images":[20,87,115,128,183],"tooth":[22,27,91,106,132],"diagnosis":[24],"through":[28],"OCT":[29,32,39,83,85,98,101,114,161],"images.":[30],"The":[31,64],"system":[33,148,162],"was":[34,56,107,163],"configured":[35],"swept":[37,46],"source":[38,47],"(SS-OCT),":[40],"is":[42,175],"with":[48,149],"center":[49],"wavelength":[50],"1310":[52],"nm,":[53],"built":[57],"using":[58,137,153],"MEMs":[59,69,150],"mirror":[60],"collimator.":[63],"implemented":[65,146],"SS-OCT":[66,147],"show":[71],"axial":[72],"resolution":[73],"10":[75,80],"\u03bcm,":[76],"scan":[77],"length":[78],"mm.":[81],"With":[82],"system,":[84],"2D":[86,113],"human":[90,105,125,131,186],"obtained":[92,108,133],"by":[93,109],"system.":[99],"3D":[100,127,191],"image":[102,192],"combining":[110],"500":[112],"also":[117],"included":[118],"internal":[119],"information":[120],"tooth.":[126],"a":[130],"were":[134],"sequentially":[135],"stitching":[136],"iterative":[139],"closet":[140],"point":[141],"(ICP).":[142],"By":[143],"equipping":[144],"probe":[151],"ICP":[154],"algorithm,":[155],"constructed":[164],"used":[166],"to":[167,177],"demonstrate":[168],"feasibility":[170],"scanner,":[173],"able":[176],"acquire":[178],"function":[182],"tooth,":[187],"for":[188],"in":[193],"dentistry.":[194]},"counts_by_year":[{"year":2022,"cited_by_count":1}],"updated_date":"2026-10-27T15:51:10.671819","created_date":"2019-07-30T00:00:00"}
