{"id":"https://openalex.org/W2961871885","doi":"https://doi.org/10.30822/arteks.v3i1.53","title":"Numeric Analysis of Air Distribution in Air-Conditioned Room to Obtain Optimum Energy Effeciency Level","display_name":"Numeric Analysis of Air Distribution in Air-Conditioned Room to Obtain Optimum Energy Effeciency Level","alternate_titles":[],"publication_year":2018,"publication_date":"2018-12-01","ids":{"openalex":"https://openalex.org/W2961871885","doi":"https://doi.org/10.30822/arteks.v3i1.53","mag":"2961871885"},"language":"en","primary_location":{"id":"doi:10.30822/arteks.v3i1.53","doi":"https://doi.org/10.30822/arteks.v3i1.53","is_oa":true,"landing_page_url":"https://doi.org/10.30822/arteks.v3i1.53","pdf_url":"https://journal.unwira.ac.id/index.php/ARTEKS/article/download/53/37","source":{"id":"https://openalex.org/S4210214341","display_name":"ARTEKS Jurnal Teknik Arsitektur","issn_l":"2541-0598","issn":["2541-0598","2541-1217"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj","sinta-s1"],"host_organization":"https://openalex.org/I4210127002","host_organization_name":"Universitas Katolik Widya Mandira","host_organization_lineage":["https://openalex.org/I4210127002"],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"ARTEKS : Jurnal Teknik Arsitektur","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2961871885"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://journal.unwira.ac.id/index.php/ARTEKS/article/download/53/37","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5028074731","display_name":"Jackobus Ade Prasetya Seputra","type":null,"orcid":"https://orcid.org/0000-0002-7897-023X","observed_orcids":["https://orcid.org/0000-0002-7897-023X"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I4210114028","display_name":"Atma Jaya University Yogyakarta","ror":"https://ror.org/01gmyr425","country_code":"ID","type":"education","lineage":["https://openalex.org/I4210114028"]}],"countries":["ID"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Jackobus Ade Prasetya Seputra","raw_affiliation_strings":["Universitas Atma Jaya Yogyakarta","Program Studi Arsitektur, Fakultas Teknik, Universitas Atma Jaya Yogyakarta Jl. Babarsari no. 44, Yogyakarta 55281, Indonesia","Program Studi Arsitektur, Fakultas Teknik, Universitas Atma Jaya Yogyakarta, Indonesia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universitas Atma Jaya Yogyakarta","institution_ids":["https://openalex.org/I4210114028"]},{"raw_affiliation_string":"Program Studi Arsitektur, Fakultas Teknik, Universitas Atma Jaya Yogyakarta Jl. Babarsari no. 44, Yogyakarta 55281, Indonesia","institution_ids":["https://openalex.org/I4210114028"]},{"raw_affiliation_string":"Program Studi Arsitektur, Fakultas Teknik, Universitas Atma Jaya Yogyakarta, Indonesia","institution_ids":["https://openalex.org/I4210114028"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5028074731"],"corresponding_institution_ids":["https://openalex.org/I4210114028"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":1,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":92},"biblio":{"volume":"3","issue":"1","first_page":"45","last_page":"56"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9951000213623047,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9951000213623047,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.004100000020116568,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/airflow-distribution","display_name":"air distribution","score":0.5199999809265137},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"air conditioning","score":0.6909999847412109},{"id":"https://openalex.org/keywords/energy-efficiency","display_name":"energy efficiency","score":0.6259999871253967},{"id":"https://openalex.org/keywords/displacement-ventilation","display_name":"displacement ventilation","score":0.8339999914169312},{"id":"https://openalex.org/keywords/perfect-mixing","display_name":"ideal mixing","score":0.8159999847412109},{"id":"https://openalex.org/keywords/radiant-cooling","display_name":"radiant cooling","score":0.9980000257492065},{"id":"https://openalex.org/keywords/indoor-thermal-comfort","display_name":"indoor thermal comfort","score":0.8799999952316284},{"id":"https://openalex.org/keywords/cooling-time","display_name":"cooling time","score":0.9369999766349792},{"id":"https://openalex.org/keywords/air-conditioning-energy-consumption","display_name":"air conditioning energy consumption","score":0.675000011920929},{"id":"https://openalex.org/keywords/heat-load","display_name":"heat load","score":0.8659999966621399},{"id":"https://openalex.org/keywords/indoor-temperature","display_name":"indoor temperature","score":0.6069999933242798}],"concepts":[{"id":"https://openalex.org/C12302492","wikidata":"https://www.wikidata.org/wiki/Q1752097","display_name":"Setpoint","level":2,"score":0.8947296738624573},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.6353468298912048},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5721936225891113},{"id":"https://openalex.org/C2781099182","wikidata":"https://www.wikidata.org/wiki/Q24963825","display_name":"Cooling load","level":3,"score":0.5479367971420288},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.5461241006851196},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.541944146156311},{"id":"https://openalex.org/C138777275","wikidata":"https://www.wikidata.org/wiki/Q6884054","display_name":"Mixing (physics)","level":2,"score":0.45873844623565674},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4373644292354584},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.4200895428657532},{"id":"https://openalex.org/C2776668771","wikidata":"https://www.wikidata.org/wiki/Q5282619","display_name":"Displacement ventilation","level":3,"score":0.4150194823741913},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.38453513383865356},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.367864191532135},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.3457731008529663},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.3214573264122009},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2793751358985901},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.26952064037323},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2678844928741455},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.20058977603912354},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1800927221775055},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1655259132385254},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.11481130123138428},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.30822/arteks.v3i1.53","doi":"https://doi.org/10.30822/arteks.v3i1.53","is_oa":true,"landing_page_url":"https://doi.org/10.30822/arteks.v3i1.53","pdf_url":"https://journal.unwira.ac.id/index.php/ARTEKS/article/download/53/37","source":{"id":"https://openalex.org/S4210214341","display_name":"ARTEKS Jurnal Teknik Arsitektur","issn_l":"2541-0598","issn":["2541-0598","2541-1217"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj","sinta-s1"],"host_organization":"https://openalex.org/I4210127002","host_organization_name":"Universitas Katolik Widya Mandira","host_organization_lineage":["https://openalex.org/I4210127002"],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"ARTEKS : Jurnal Teknik Arsitektur","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:787e860facfd4073b95f0740ff85feea","doi":null,"is_oa":false,"landing_page_url":"https://doaj.org/article/787e860facfd4073b95f0740ff85feea","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ARTEKS : Jurnal Teknik Arsitektur, Vol 3, Iss 1 (2018)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.30822/arteks.v3i1.53","doi":"https://doi.org/10.30822/arteks.v3i1.53","is_oa":true,"landing_page_url":"https://doi.org/10.30822/arteks.v3i1.53","pdf_url":"https://journal.unwira.ac.id/index.php/ARTEKS/article/download/53/37","source":{"id":"https://openalex.org/S4210214341","display_name":"ARTEKS Jurnal Teknik Arsitektur","issn_l":"2541-0598","issn":["2541-0598","2541-1217"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj","sinta-s1"],"host_organization":"https://openalex.org/I4210127002","host_organization_name":"Universitas Katolik Widya Mandira","host_organization_lineage":["https://openalex.org/I4210127002"],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"ARTEKS : Jurnal Teknik Arsitektur","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.8485000133514404,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2961871885.pdf","grobid_xml":"https://content.openalex.org/works/W2961871885.grobid-xml"},"referenced_works_count":1,"referenced_works":["https://openalex.org/W2305435675"],"related_works":["https://openalex.org/W2955828482","https://openalex.org/W2918485268","https://openalex.org/W1967425698","https://openalex.org/W2014908131","https://openalex.org/W2262786208","https://openalex.org/W7212371077","https://openalex.org/W2353080550","https://openalex.org/W2390915134","https://openalex.org/W2976907363","https://openalex.org/W4382402920"],"abstract_inverted_index":{"The":[0,111],"demand":[1],"for":[2],"household":[3],"energy":[4,59],"in":[5,119,125,134],"Indonesia":[6],"is":[7,22,101,115,131],"dominated":[8],"by":[9,69,117,146],"air":[10,19,28,35,89,147],"conditioning":[11],"sector.":[12],"One":[13],"of":[14,38,55,87,91,142,170],"the":[15,26,53,82,109,129],"efforts":[16],"to":[17,23,61,107],"optimize":[18],"conditioner":[20],"(AC)":[21],"figure":[24],"out":[25],"best":[27],"distribution":[29,36],"pattern.":[30],"Nowadays,":[31],"there":[32],"are":[33],"three":[34,140],"types":[37,57],"marketed":[39],"AC;":[40],"(1)":[41],"perfect":[42,123,186],"mixing,":[43],"(2)":[44],"displacement,":[45],"and":[46,75,128,161,181,193,205],"(3)":[47],"radiant":[48,132,198],"cooling.":[49],"This":[50],"research":[51,83],"examines":[52],"influence":[54],"those":[56],"toward":[58],"consuption":[60],"ensure":[62],"indoor":[63,88],"thermal":[64],"comfort.":[65],"It":[66],"was":[67],"conducted":[68],"conducting":[70],"literature":[71],"review,":[72],"mathematical":[73],"calculation,":[74],"numerical":[76],"simulation.":[77],"Based":[78],"on":[79,104],"SNI":[80],"03-6572-2001,":[81],"applied":[84],"comfort":[85],"criteria":[86],"temperature":[90],"24oC":[92],"as":[93],"setpoint":[94],"with":[95],"28.1oC":[96],"initial":[97],"temperature.":[98],"Energy":[99,137],"consumption":[100],"estimated":[102],"based":[103],"time":[105,114,172],"required":[106],"achieve":[108],"setpoint.":[110],"fastest":[112],"cooling":[113,133,199],"obtained":[116],"displacement":[118,175],"80":[120],"seconds,":[121,127,155,160],"then":[122],"mixing":[124,187],"112":[126],"longest":[130],"460":[135],"seconds.":[136,166],"calculation":[138],"establishes":[139],"scenarios":[141],"heat":[143],"load":[144],"represented":[145],"con\u2019s":[148],"idle":[149],"time;":[150],"(a)":[151,177,189,201],"high":[152],"load,":[153,158,164],"30":[154],"(b)":[156,179,191,203],"moderate":[157],"60":[159],"(c)":[162,182,194,206],"low":[163],"90":[165],"For":[167],"300":[168],"hours":[169],"operational":[171],"per":[173],"month,":[174],"consumes":[176],"148.4,":[178],"116.6,":[180],"96":[183],"kWh/month,":[184],"whilst":[185],"needs":[188],"160.9,":[190],"132.8,":[192],"113.1":[195],"kWh/month.":[196,208],"Lastly,":[197],"spends":[200],"191.5,":[202],"180.5,":[204],"170.6":[207]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2961871885","counts_by_year":[{"year":2024,"cited_by_count":1}],"updated_date":"2026-11-25T09:40:18.809321","created_date":"2019-07-23T00:00:00"}