{"id":"https://openalex.org/W2955364981","doi":"https://doi.org/10.1109/icieam.2019.8742909","title":"Using Battery Energy Storage Systems for Load Balancing and Reactive Power Compensation in Distribution Grids","display_name":"Using Battery Energy Storage Systems for Load Balancing and Reactive Power Compensation in Distribution Grids","publication_year":2019,"publication_date":"2019-03-01","ids":{"openalex":"https://openalex.org/W2955364981","doi":"https://doi.org/10.1109/icieam.2019.8742909","mag":"2955364981"},"language":"en","primary_location":{"id":"doi:10.1109/icieam.2019.8742909","doi":"https://doi.org/10.1109/icieam.2019.8742909","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icieam.2019.8742909","pdf_url":null,"source":{"id":"https://openalex.org/S4363608063","display_name":"International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2955364981"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5062938136","display_name":"Yu. P. Gusev","orcid":"https://orcid.org/0000-0002-1814-6791","observed_orcids":["https://orcid.org/0000-0002-1814-6791"]},"institutions":[{"id":"https://openalex.org/I171241948","display_name":"Moscow Power Engineering Institute","ror":"https://ror.org/05sa6gg87","country_code":"RU","type":"education","lineage":["https://openalex.org/I171241948"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"Y. P. Gusev","raw_affiliation_strings":["National Research University \u00abMoscow Power Engineering Institute\u00bb, Moscow, Russian Federation"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Research University \u00abMoscow Power Engineering Institute\u00bb, Moscow, Russian Federation","institution_ids":["https://openalex.org/I171241948"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5063808619","display_name":"P. V. Subbotin","orcid":"https://orcid.org/0000-0001-6779-3787","observed_orcids":["https://orcid.org/0000-0001-6779-3787"]},"institutions":[{"id":"https://openalex.org/I171241948","display_name":"Moscow Power Engineering Institute","ror":"https://ror.org/05sa6gg87","country_code":"RU","type":"education","lineage":["https://openalex.org/I171241948"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"P. V. Subbotin","raw_affiliation_strings":["National Research University \u00abMoscow Power Engineering Institute\u00bb, Moscow, Russian Federation"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Research University \u00abMoscow Power Engineering Institute\u00bb, Moscow, Russian Federation","institution_ids":["https://openalex.org/I171241948"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I171241948"],"apc_list":null,"apc_paid":null,"fwci":3.1689,"has_fulltext":false,"cited_by_count":23,"citation_normalized_percentile":{"value":0.92546441,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":91,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9463000297546387,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9463000297546387,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.03620000183582306,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.008500000461935997,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/battery-energy-storage","display_name":"battery energy storage","score":1.0},{"id":"https://openalex.org/keywords/load-balancing","display_name":"load balancing","score":0.968999981880188},{"id":"https://openalex.org/keywords/reactive-power-compensation","display_name":"reactive power compensation","score":1.0},{"id":"https://openalex.org/keywords/distribution-networks","display_name":"distribution networks","score":0.9869999885559082},{"id":"https://openalex.org/keywords/unbalanced-loading","display_name":"unbalanced loads","score":0.9020000100135803},{"id":"https://openalex.org/keywords/negative-sequence-compensation","display_name":"negative sequence compensation","score":0.7540000081062317},{"id":"https://openalex.org/keywords/power-quality","display_name":"power quality","score":0.7820000052452087}],"concepts":[{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.6267180442810059},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.5891513824462891},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.5715309381484985},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.565736711025238},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.554844319820404},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5261684656143188},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5131962895393372},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.49826598167419434},{"id":"https://openalex.org/C138959212","wikidata":"https://www.wikidata.org/wiki/Q1806783","display_name":"Load balancing (electrical power)","level":3,"score":0.45182132720947266},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.44834113121032715},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.41908133029937744},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.39802706241607666},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.36168262362480164},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3586735129356384},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.35088521242141724},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icieam.2019.8742909","doi":"https://doi.org/10.1109/icieam.2019.8742909","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icieam.2019.8742909","pdf_url":null,"source":{"id":"https://openalex.org/S4363608063","display_name":"International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9853000044822693,"id":"https://metadata.un.org/sdg/7"},{"display_name":"Industry, innovation and infrastructure","score":0.8970999717712402,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1979888601","https://openalex.org/W1991918395","https://openalex.org/W2016399633","https://openalex.org/W2064038783","https://openalex.org/W2185879173","https://openalex.org/W2539669639","https://openalex.org/W2740430497","https://openalex.org/W2789425440","https://openalex.org/W2958822407","https://openalex.org/W4206555549","https://openalex.org/W4210508120"],"related_works":["https://openalex.org/W4293209997","https://openalex.org/W2998164922","https://openalex.org/W4210370894","https://openalex.org/W4291652818","https://openalex.org/W3099982076","https://openalex.org/W7167511924","https://openalex.org/W4414877067","https://openalex.org/W4225724336","https://openalex.org/W3088338787","https://openalex.org/W4404133195"],"abstract_inverted_index":{"The":[0,72,140],"paper":[1,73,141],"evaluates":[2],"current":[3],"equipment":[4],"conditions":[5],"and":[6,28,68,102,146],"electricity":[7],"quality":[8],"in":[9,32,57,177],"distribution":[10,33,178],"grids.":[11,34,179],"It":[12,120],"proposes":[13],"an":[14],"innovative":[15],"technical":[16],"solution":[17],"to":[18,47,85,105,108,159],"use":[19],"battery":[20],"energy":[21],"storage":[22,138],"systems":[23],"(BESS)":[24],"for":[25,115],"load":[26,160],"balancing":[27,95,161],"reactive":[29,175],"power":[30,176],"compensation":[31],"Analysis":[35],"of":[36,44,66,92,112,137,149],"the":[37,42,51,61,75,93,109,117,126,134,143,147,150,157,164,174],"effective":[38],"Russian":[39],"standards":[40],"identifies":[41],"lack":[43],"regulatory":[45],"requirements":[46,107],"BESS":[48,70,103,113,153],"functionality.":[49],"Given":[50],"latest":[52],"advances":[53],"made":[54],"by":[55,162,172],"manufacturers":[56],"solving":[58,116],"distribution-grid":[59],"problems,":[60],"authors":[62],"propose":[63],"a":[64],"combination":[65],"primary":[67],"secondary":[69,127],"functions.":[71],"analyzes":[74],"main":[76],"reasons":[77],"behind":[78],"unbalanced":[79],"loads":[80],"as":[81,83,98,169,171],"well":[82,170],"how":[84],"balance":[86],"them.":[87],"A":[88],"comparative":[89],"parametric":[90],"analysis":[91,130],"conventional":[94],"devices,":[96],"such":[97],"capacitor":[99],"batteries":[100],"(CB)":[101],"helped":[104],"draw":[106],"rated":[110],"capacity":[111],"converters":[114],"stated":[118],"problems.":[119],"is":[121],"additionally":[122],"found":[123],"that":[124],"running":[125],"functions":[128],"under":[129],"will":[131],"not":[132],"affect":[133],"service":[135],"life":[136],"systems.":[139],"states":[142],"practical":[144],"significance":[145],"efficiency":[148],"proposed":[151],"solution.":[152],"can":[154],"radically":[155],"change":[156],"approach":[158],"compensating":[163,173],"negative-":[165],"and/or":[166],"zero-sequence":[167],"currents":[168]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":2}],"updated_date":"2026-11-14T11:04:58.165337","created_date":"2019-07-12T00:00:00"}
