{"id":"https://openalex.org/W2947469607","doi":null,"title":"Risk of Lightning Strike to Wind Turbines for Maintenance Personnel Inside the Hub","display_name":"Risk of Lightning Strike to Wind Turbines for Maintenance Personnel Inside the Hub","publication_year":2006,"publication_date":"2006-01-01","ids":{"openalex":"https://openalex.org/W2947469607","mag":"2947469607"},"language":"en","primary_location":{"id":"pmh:oai:mediatum.ub.tum.de:node/1128445","doi":null,"is_oa":false,"landing_page_url":"http://mediatum.ub.tum.de/node?id=1128445","pdf_url":null,"source":{"id":"https://openalex.org/S4306400453","display_name":"mediaTUM \u2013 the media and publications repository of the Technical University Munich (Technical University Munich)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I62916508","host_organization_name":"Technical University of Munich","host_organization_lineage":["https://openalex.org/I62916508"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5008939940","display_name":"Bastian Lewke","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"B. Lewke","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000678164","display_name":"Florian Krug","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"F. Krug","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5028325216","display_name":"Josef Kindersberger","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J. Kindersberger","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.3983,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.65201395,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"1527","last_page":"1532"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10787","display_name":"Lightning and Electromagnetic Phenomena","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10787","display_name":"Lightning and Electromagnetic Phenomena","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11851","display_name":"Electromagnetic Compatibility and Measurements","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11263","display_name":"Electromagnetic Simulation and Numerical Methods","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/lightning-strikes","display_name":"lightning strikes","score":0.7239999771118164},{"id":"https://openalex.org/keywords/wind-turbines","display_name":"wind turbines","score":0.9810000061988831},{"id":"https://openalex.org/keywords/wind-turbine-hub","display_name":"wind turbine hub","score":0.6330000162124634},{"id":"https://openalex.org/keywords/maintenance-personnel","display_name":"maintenance personnel","score":0.8240000009536743},{"id":"https://openalex.org/keywords/faraday-cage","display_name":"Faraday cage","score":0.765999972820282},{"id":"https://openalex.org/keywords/induced-voltage","display_name":"induced voltage","score":0.7979999780654907},{"id":"https://openalex.org/keywords/magnetic-field","display_name":"magnetic field","score":0.8460000157356262},{"id":"https://openalex.org/keywords/shock-waves","display_name":"shock waves","score":0.8809999823570251},{"id":"https://openalex.org/keywords/control-box","display_name":"control box","score":0.8650000095367432},{"id":"https://openalex.org/keywords/cast-iron","display_name":"cast iron","score":0.6679999828338623},{"id":"https://openalex.org/keywords/method-of-moments-simulation","display_name":"method of moments simulation","score":0.6919999718666077},{"id":"https://openalex.org/keywords/near-field-measurement","display_name":"near-field measurement","score":0.7160000205039978},{"id":"https://openalex.org/keywords/surge-current","display_name":"surge current","score":0.5550000071525574},{"id":"https://openalex.org/keywords/lightning-protection","display_name":"lightning protection","score":0.6309999823570251}],"concepts":[{"id":"https://openalex.org/C182236062","wikidata":"https://www.wikidata.org/wiki/Q15120872","display_name":"Lightning strike","level":3,"score":0.8597134351730347},{"id":"https://openalex.org/C69398868","wikidata":"https://www.wikidata.org/wiki/Q129052","display_name":"Lightning (connector)","level":3,"score":0.6559606194496155},{"id":"https://openalex.org/C108948954","wikidata":"https://www.wikidata.org/wiki/Q208138","display_name":"Faraday cage","level":3,"score":0.5444307923316956},{"id":"https://openalex.org/C2265751","wikidata":"https://www.wikidata.org/wiki/Q332007","display_name":"Electromagnetic shielding","level":2,"score":0.4894648790359497},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4784017503261566},{"id":"https://openalex.org/C80316258","wikidata":"https://www.wikidata.org/wiki/Q2857578","display_name":"Thunderstorm","level":2,"score":0.4642760157585144},{"id":"https://openalex.org/C199104240","wikidata":"https://www.wikidata.org/wiki/Q118291","display_name":"Marine engineering","level":1,"score":0.4589577317237854},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.44253817200660706},{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.2794039845466614},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.27654168009757996},{"id":"https://openalex.org/C115260700","wikidata":"https://www.wikidata.org/wiki/Q11408","display_name":"Magnetic field","level":2,"score":0.2724844813346863},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.22316008806228638},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:mediatum.ub.tum.de:node/1128445","doi":null,"is_oa":false,"landing_page_url":"http://mediatum.ub.tum.de/node?id=1128445","pdf_url":null,"source":{"id":"https://openalex.org/S4306400453","display_name":"mediaTUM \u2013 the media and publications repository of the Technical University Munich (Technical University Munich)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I62916508","host_organization_name":"Technical University of Munich","host_organization_lineage":["https://openalex.org/I62916508"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"article"},{"id":"mag:2947469607","doi":null,"is_oa":false,"landing_page_url":"https://mediatum.ub.tum.de/node?id=1128445","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"International Conference on Lightning Protection","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2948191781","https://openalex.org/W3129815795","https://openalex.org/W2110337131","https://openalex.org/W2757054084","https://openalex.org/W2140115506","https://openalex.org/W2077594199","https://openalex.org/W6981421065","https://openalex.org/W2784070477","https://openalex.org/W1520481988","https://openalex.org/W2971620736"],"abstract_inverted_index":{"Wind":[0],"Turbines":[1],"offer":[2],"preferred":[3],"impact":[4],"spots":[5],"to":[6,33,71,80,157,166],"lightning,":[7],"bearing":[8],"high":[9],"risks":[10],"for":[11],"humans":[12,72],"being":[13],"on":[14,23],"or":[15],"in":[16],"the":[17,24,30,34,36,46,58,63,74,111,116,120,148,162,174],"facility":[18],"during":[19,29,108,151],"a":[20,27,95,122,138],"thunderstorm.":[21],"Depending":[22],"position":[25],"of":[26,57,62,173],"person":[28],"lightning":[31,100,153],"strike":[32],"facility,":[35],"risk":[37],"varies.":[38],"In":[39],"case":[40],"maintenance":[41],"work":[42],"is":[43,125],"done":[44],"inside":[45,73,119],"hub,":[47,121],"people":[48],"and":[49,84,87,102],"electronics":[50,112],"are":[51,76,105],"protected":[52],"against":[53,99],"direct":[54],"strikes":[55],"because":[56],"Faraday":[59],"cage":[60],"structure":[61],"hub.":[64,149],"Major":[65],"phenomena":[66],"that":[67,92,143],"may":[68,160],"be":[69,167],"hazardous":[70],"hub":[75],"induced":[77,103],"voltages":[78,86],"due":[79],"magnetic":[81,117],"fields,":[82],"step":[83],"touch":[85],"shock":[88],"waves.":[89],"Control":[90],"boxes":[91],"normally":[93],"form":[94],"closed":[96],"metallic":[97],"shielding":[98],"current":[101,142],"fields":[104,118],"usually":[106],"open":[107],"maintenance,":[109],"leaving":[110],"unprotected.":[113],"To":[114],"specify":[115],"method-of-moments":[123],"simulation":[124],"used,":[126],"validated":[127],"by":[128],"respective":[129],"near":[130],"field":[131],"measurements.":[132],"The":[133],"measurements":[134],"were":[135],"performed":[136],"using":[137],"1.3":[139],"kA":[140,159],"surge":[141],"has":[144,165],"been":[145],"injected":[146],"into":[147,178],"As":[150],"real":[152],"strikes,":[154],"currents":[155],"up":[156],"200":[158],"occur,":[161],"numeric":[163],"model":[164],"extrapolated":[168],"taking":[169],"nonlinear":[170],"material":[171],"effects":[172],"hub\u2019s":[175],"cast":[176],"iron":[177],"account.":[179]},"counts_by_year":[{"year":2018,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2026-10-05T09:50:58.205359","created_date":"2019-06-07T00:00:00"}
