{"id":"https://openalex.org/W2944934805","doi":"https://doi.org/10.1109/spin.2019.8711605","title":"A Three-Phase Asymmetric Multilevel Inverter for Standalone PV Systems","display_name":"A Three-Phase Asymmetric Multilevel Inverter for Standalone PV Systems","publication_year":2019,"publication_date":"2019-03-01","ids":{"openalex":"https://openalex.org/W2944934805","doi":"https://doi.org/10.1109/spin.2019.8711605","mag":"2944934805"},"language":"en","primary_location":{"id":"doi:10.1109/spin.2019.8711605","doi":"https://doi.org/10.1109/spin.2019.8711605","is_oa":false,"landing_page_url":"https://doi.org/10.1109/spin.2019.8711605","pdf_url":null,"source":{"id":"https://openalex.org/S7407088352","display_name":"International Conference on Signal Processing and Integrated Networks (SPIN)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 6th International Conference on Signal Processing and Integrated Networks (SPIN)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100720037","display_name":"Sumit Kumar","orcid":"https://orcid.org/0000-0002-6920-4728","observed_orcids":["https://orcid.org/0000-0002-6920-4728"]},"institutions":[{"id":"https://openalex.org/I105094715","display_name":"National Institute of Technology Kurukshetra","ror":"https://ror.org/04909p852","country_code":"IN","type":"education","lineage":["https://openalex.org/I105094715"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sumit Kumar","raw_affiliation_strings":["Department of Electrical Engineering, National Institute of technology, Kurukshetra, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, National Institute of technology, Kurukshetra, India","institution_ids":["https://openalex.org/I105094715"]}]},{"author_position":"last","author":{"id":null,"display_name":"Yash Pal","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I105094715","display_name":"National Institute of Technology Kurukshetra","ror":"https://ror.org/04909p852","country_code":"IN","type":"education","lineage":["https://openalex.org/I105094715"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Yash Pal","raw_affiliation_strings":["Department of Electrical Engineering, National Institute of technology, Kurukshetra, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, National Institute of technology, Kurukshetra, India","institution_ids":["https://openalex.org/I105094715"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I105094715"],"apc_list":null,"apc_paid":null,"fwci":2.7847,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.90520574,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"357","last_page":"361"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/asymmetric-multilevel-inverter","display_name":"asymmetrical multilevel inverter","score":0.9470000267028809},{"id":"https://openalex.org/keywords/three-phase-inverter","display_name":"three-phase inverter","score":0.8379999995231628},{"id":"https://openalex.org/keywords/cascaded-h-bridge-multilevel-inverter","display_name":"cascaded H-bridge inverter","score":0.9509999752044678},{"id":"https://openalex.org/keywords/stand-alone-photovoltaic-systems","display_name":"stand-alone photovoltaic systems","score":0.9319999814033508},{"id":"https://openalex.org/keywords/transformerless-inverter","display_name":"transformerless inverter","score":0.8840000033378601},{"id":"https://openalex.org/keywords/total-harmonic-distortion-reduction","display_name":"total harmonic distortion reduction","score":0.9020000100135803},{"id":"https://openalex.org/keywords/carrier-based-modulation","display_name":"carrier-based modulation","score":0.949999988079071},{"id":"https://openalex.org/keywords/gate-pulse-generation","display_name":"gate pulse generation","score":0.8309999704360962},{"id":"https://openalex.org/keywords/power-quality","display_name":"power quality","score":0.9419999718666077}],"concepts":[{"id":"https://openalex.org/C42156128","wikidata":"https://www.wikidata.org/wiki/Q162641","display_name":"Total harmonic distortion","level":3,"score":0.8489152193069458},{"id":"https://openalex.org/C2778512005","wikidata":"https://www.wikidata.org/wiki/Q1545300","display_name":"H bridge","level":4,"score":0.7922612428665161},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.7823899984359741},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.7731386423110962},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.534291684627533},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.49719932675361633},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4913100302219391},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.4716213047504425},{"id":"https://openalex.org/C123079801","wikidata":"https://www.wikidata.org/wiki/Q750240","display_name":"Modulation (music)","level":2,"score":0.4694262146949768},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.452913761138916},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.425969660282135},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.37124860286712646},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.3427315652370453},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3407366871833801},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3306404650211334},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.22718742489814758},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0985613763332367},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/spin.2019.8711605","doi":"https://doi.org/10.1109/spin.2019.8711605","is_oa":false,"landing_page_url":"https://doi.org/10.1109/spin.2019.8711605","pdf_url":null,"source":{"id":"https://openalex.org/S7407088352","display_name":"International Conference on Signal Processing and Integrated Networks (SPIN)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 6th International Conference on Signal Processing and Integrated Networks (SPIN)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9090999960899353,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W1978822783","https://openalex.org/W2030973541","https://openalex.org/W2035139050","https://openalex.org/W2064495614","https://openalex.org/W2078774983","https://openalex.org/W2090296553","https://openalex.org/W2095776325","https://openalex.org/W2100020874","https://openalex.org/W2101238422","https://openalex.org/W2101494224","https://openalex.org/W2136109242","https://openalex.org/W2192523407","https://openalex.org/W2336079340","https://openalex.org/W2347797181","https://openalex.org/W2533789359"],"related_works":["https://openalex.org/W4292002581","https://openalex.org/W3003298863","https://openalex.org/W4200624613","https://openalex.org/W2487448846","https://openalex.org/W2765671132","https://openalex.org/W2471951490","https://openalex.org/W2041824411","https://openalex.org/W3205847393","https://openalex.org/W4301396753","https://openalex.org/W3153985173"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"an":[3,32,98],"asymmetric":[4,13,33,99,123],"cascaded":[5,34,74,100,124],"H-bridge":[6,35,75,101,125],"multilevel":[7,14,36,59,76,102,126],"inverter":[8,15,103,127],"for":[9,19,69,104,128],"photovoltaic":[10,20,106],"system.":[11,131],"The":[12,115],"is":[16,42,85,110],"perfect":[17],"solution":[18],"system":[21],"because":[22],"it":[23],"enhances":[24],"power":[25],"quality":[26],"and":[27,49,120],"enable":[28],"transformerless":[29],"operation.":[30],"In":[31],"inverter,":[37],"different":[38,62],"levels":[39,48],"of":[40,81,91,97,122],"voltage":[41,47],"applied":[43],"which":[44],"enhance":[45],"output":[46],"reduces":[50],"Total":[51],"Harmonic":[52],"Distortion":[53],"(THD)":[54],"as":[55],"compared":[56],"to":[57,73],"symmetrical":[58],"inverter.":[60,77],"Two":[61],"carrier":[63],"based":[64],"modulation":[65,83],"techniques":[66,84],"are":[67],"used":[68],"providing":[70],"gate":[71],"pulses":[72],"A":[78],"comparative":[79],"analysis":[80],"two":[82],"also":[86],"carried":[87,111],"out":[88,112],"in":[89],"terms":[90],"THD.":[92],"To":[93],"validate":[94],"the":[95,108,118],"performance":[96],"a":[105,129],"system,":[107],"modeling":[109],"using":[113],"MATLAB/simulink.":[114],"result":[116],"verifies":[117],"advantages":[119],"reliability":[121],"PV":[130]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":3}],"updated_date":"2026-10-05T09:50:58.205359","created_date":"2019-05-29T00:00:00"}
