{"id":"https://openalex.org/W2943377382","doi":null,"title":"Protocol for establishing and maintaining the calibration of medical radionuclide calibrators and their quality control.","display_name":"Protocol for establishing and maintaining the calibration of medical radionuclide calibrators and their quality control.","alternate_titles":[],"publication_year":2006,"publication_date":"2006-05-01","ids":{"openalex":"https://openalex.org/W2943377382","mag":"2943377382"},"language":"en","primary_location":{"id":"mag:2943377382","doi":null,"is_oa":false,"landing_page_url":"https://eprintspublications.npl.co.uk/3661/","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2943377382"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5002836115","display_name":"R. Gadd","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"R. Gadd","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113027880","display_name":"M. Baker","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"M. Baker","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5052995669","display_name":"Kuldip S. Nijran","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"K. S. Nijran","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Scott R. Owens","orcid":"https://orcid.org/0000-0001-6203-8766","observed_orcids":["https://orcid.org/0000-0001-6203-8766"]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Scott R. Owens","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0001-6203-8766","affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"W Thomas","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"W Thomas","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112054984","display_name":"M.J. Woods","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"M.J. Woods","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5113225789","display_name":"F V Zananiri","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"F V Zananiri","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.8519,"has_fulltext":false,"cited_by_count":59,"citation_normalized_percentile":{"value":0.69984607,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":98},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13414","display_name":"Radioactive Decay and Measurement Techniques","score":0.9663000106811523,"subfield":{"id":"https://openalex.org/subfields/3108","display_name":"Radiation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13414","display_name":"Radioactive Decay and Measurement Techniques","score":0.9663000106811523,"subfield":{"id":"https://openalex.org/subfields/3108","display_name":"Radiation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.012900000438094139,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11395","display_name":"Radiopharmaceutical Chemistry and Applications","score":0.00800000037997961,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/quality-control","display_name":"quality control","score":0.6380000114440918},{"id":"https://openalex.org/keywords/measurement-traceability","display_name":"measurement traceability","score":0.8489999771118164},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"measurement uncertainty","score":0.8690000176429749},{"id":"https://openalex.org/keywords/sources-of-error","display_name":"error sources","score":0.7820000052452087},{"id":"https://openalex.org/keywords/calibration","display_name":"calibration","score":0.375}],"concepts":[{"id":"https://openalex.org/C153876917","wikidata":"https://www.wikidata.org/wiki/Q899704","display_name":"Traceability","level":2,"score":0.8864027261734009},{"id":"https://openalex.org/C158973077","wikidata":"https://www.wikidata.org/wiki/Q192900","display_name":"Radionuclide","level":2,"score":0.6545394062995911},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.5899320840835571},{"id":"https://openalex.org/C2780385302","wikidata":"https://www.wikidata.org/wiki/Q367158","display_name":"Protocol (science)","level":3,"score":0.579204261302948},{"id":"https://openalex.org/C2779530757","wikidata":"https://www.wikidata.org/wiki/Q1207505","display_name":"Quality (philosophy)","level":2,"score":0.5461616516113281},{"id":"https://openalex.org/C106436119","wikidata":"https://www.wikidata.org/wiki/Q836575","display_name":"Quality assurance","level":3,"score":0.5128741264343262},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4618811309337616},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46154338121414185},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.43860718607902527},{"id":"https://openalex.org/C51704429","wikidata":"https://www.wikidata.org/wiki/Q827792","display_name":"Quality control","level":3,"score":0.42244693636894226},{"id":"https://openalex.org/C19527891","wikidata":"https://www.wikidata.org/wiki/Q1120908","display_name":"Medical physics","level":1,"score":0.38915950059890747},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.2832176983356476},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.25559020042419434},{"id":"https://openalex.org/C2778618615","wikidata":"https://www.wikidata.org/wiki/Q4008393","display_name":"External quality assessment","level":2,"score":0.22787702083587646},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22156557440757751},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.17310261726379395},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.13999107480049133},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.1117798388004303},{"id":"https://openalex.org/C115903868","wikidata":"https://www.wikidata.org/wiki/Q80993","display_name":"Software engineering","level":1,"score":0.07523393630981445},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0665457546710968},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0},{"id":"https://openalex.org/C204787440","wikidata":"https://www.wikidata.org/wiki/Q188504","display_name":"Alternative medicine","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2943377382","doi":null,"is_oa":false,"landing_page_url":"https://eprintspublications.npl.co.uk/3661/","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2089560676","https://openalex.org/W2315214008","https://openalex.org/W2344033098","https://openalex.org/W2566077632"],"related_works":["https://openalex.org/W7125782094","https://openalex.org/W1039951218","https://openalex.org/W2007015496","https://openalex.org/W6885078735","https://openalex.org/W1967522607","https://openalex.org/W4285176517","https://openalex.org/W2047801721","https://openalex.org/W2922352149","https://openalex.org/W1981184088","https://openalex.org/W1968114684"],"abstract_inverted_index":{"Guidance":[0],"is":[1],"given":[2],"on":[3,11],"the":[4,21,28],"quality":[5],"controls":[6],"that":[7],"should":[8],"be":[9],"undertaken":[10],"a":[12],"routine":[13],"basis":[14],"for":[15],"medical":[16],"radionuclide":[17],"calibrators":[18],"to":[19],"ensure":[20],"accuracy":[22],"and":[23,35],"traceability":[24],"of":[25,27,30,33,37],"measurements":[26],"activities":[29],"radiopharmaceuticals.":[31],"Sources":[32],"error":[34],"magnitudes":[36],"associated":[38],"uncertainties":[39],"are":[40],"discussed.":[41]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2943377382","counts_by_year":[{"year":2026,"cited_by_count":5},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":6},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2019-05-09T00:00:00"}
