{"id":"https://openalex.org/W2936020144","doi":"https://doi.org/10.14171/j.2096-5117.gei.2018.03.005","title":"New two chamber transfer switch for 6500 A commutation current","display_name":"New two chamber transfer switch for 6500 A commutation current","alternate_titles":[],"publication_year":2018,"publication_date":"2018-08-01","ids":{"openalex":"https://openalex.org/W2936020144","doi":"https://doi.org/10.14171/j.2096-5117.gei.2018.03.005","mag":"2936020144"},"language":"en","primary_location":{"id":"mag:2936020144","doi":"https://doi.org/10.14171/j.2096-5117.gei.2018.03.005","is_oa":true,"landing_page_url":"https://www.sciencedirect.com/science/article/pii/S2096511718300458","pdf_url":null,"source":{"id":"https://openalex.org/S4210177181","display_name":"Global Energy Interconnection","issn_l":"2096-5117","issn":["2096-5117","2590-0358"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-d","jufo-1","norway-1","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Global Energy Interconnection","raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2936020144"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["doaj"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://www.sciencedirect.com/science/article/pii/S2096511718300458","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5053867861","display_name":"Lutz-R\u00fcdiger J\u00e4nicke","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I1325886976","display_name":"Siemens (Germany)","ror":"https://ror.org/059mq0909","country_code":"DE","type":"company","lineage":["https://openalex.org/I1325886976"]}],"countries":["DE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Lutz-R\u00fcdiger J\u00e4nicke","raw_affiliation_strings":["Siemens AG, Nonnendammallee 104, 13629 Berlin, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Siemens AG, Nonnendammallee 104, 13629 Berlin, Germany","institution_ids":["https://openalex.org/I1325886976"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053544846","display_name":"J\u00f6rg Teichmann","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I1325886976","display_name":"Siemens (Germany)","ror":"https://ror.org/059mq0909","country_code":"DE","type":"company","lineage":["https://openalex.org/I1325886976"]}],"countries":["DE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"J. Teichmann","raw_affiliation_strings":["Siemens AG, Nonnendammallee 104, 13629 Berlin, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Siemens AG, Nonnendammallee 104, 13629 Berlin, Germany","institution_ids":["https://openalex.org/I1325886976"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053217217","display_name":"S. Bose","type":null,"orcid":"https://orcid.org/0000-0003-3529-3854","observed_orcids":["https://orcid.org/0000-0003-3529-3854"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I51629411","display_name":"Siemens (China)","ror":"https://ror.org/00v6g9845","country_code":"CN","type":"company","lineage":["https://openalex.org/I1325886976","https://openalex.org/I51629411"]}],"countries":["CN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"S. Bose","raw_affiliation_strings":["Siemens Ltd. China, 43 Ximei Road, 214028 Wuxi, P.R. China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Siemens Ltd. China, 43 Ximei Road, 214028 Wuxi, P.R. China","institution_ids":["https://openalex.org/I51629411"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004041347","display_name":"Han Wei-dong","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Han Wei-dong","raw_affiliation_strings":["Siemens High voltage Circuit Breaker Co., Ltd., 6th Road, 310018 Hangzhou, P.R. China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Siemens High voltage Circuit Breaker Co., Ltd., 6th Road, 310018 Hangzhou, P.R. China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5004684888","display_name":"Xiaoming Wang","type":null,"orcid":"https://orcid.org/0000-0003-2784-7140","observed_orcids":["https://orcid.org/0000-0003-2784-7140"]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Xiaoming Wang","raw_affiliation_strings":["Siemens High voltage Circuit Breaker Co., Ltd., 6th Road, 310018 Hangzhou, P.R. China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Siemens High voltage Circuit Breaker Co., Ltd., 6th Road, 310018 Hangzhou, P.R. China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0885,"has_fulltext":false,"cited_by_count":2,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.34508681,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":94},"biblio":{"volume":"1","issue":"3","first_page":"344","last_page":"351"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9951000213623047,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9951000213623047,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.0019000000320374966,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10361","display_name":"Silicon Carbide Semiconductor Technologies","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/commutation-current","display_name":"commutation current","score":0.7630000114440918},{"id":"https://openalex.org/keywords/hvdc-transmission","display_name":"HVDC transmission","score":0.7490000128746033},{"id":"https://openalex.org/keywords/overload-current","display_name":"current overload","score":0.7260000109672546},{"id":"https://openalex.org/keywords/switching-unit","display_name":"switching unit","score":0.5080000162124634},{"id":"https://openalex.org/keywords/switch-design","display_name":"switch design","score":0.5270000100135803}],"concepts":[{"id":"https://openalex.org/C2780147050","wikidata":"https://www.wikidata.org/wiki/Q5155085","display_name":"Commutation","level":3,"score":0.9373525977134705},{"id":"https://openalex.org/C2776175482","wikidata":"https://www.wikidata.org/wiki/Q1195816","display_name":"Transfer (computing)","level":2,"score":0.6500916481018066},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.6138525009155273},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.49505916237831116},{"id":"https://openalex.org/C2776299755","wikidata":"https://www.wikidata.org/wiki/Q432449","display_name":"Carry (investment)","level":2,"score":0.4735549986362457},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4451017379760742},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.41600751876831055},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3783184587955475},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.342492938041687},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2235395908355713},{"id":"https://openalex.org/C10138342","wikidata":"https://www.wikidata.org/wiki/Q43015","display_name":"Finance","level":1,"score":0.0},{"id":"https://openalex.org/C173608175","wikidata":"https://www.wikidata.org/wiki/Q232661","display_name":"Parallel computing","level":1,"score":0.0},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"mag:2936020144","doi":"https://doi.org/10.14171/j.2096-5117.gei.2018.03.005","is_oa":true,"landing_page_url":"https://www.sciencedirect.com/science/article/pii/S2096511718300458","pdf_url":null,"source":{"id":"https://openalex.org/S4210177181","display_name":"Global Energy Interconnection","issn_l":"2096-5117","issn":["2096-5117","2590-0358"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-d","jufo-1","norway-1","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Global Energy Interconnection","raw_type":null},{"id":"pmh:oai:doaj.org/article:ea44e3dc25124a448bea57daefdb1c6e","doi":"https://doi.org/10.14171/j.2096-5117.gei.2018.03.005","is_oa":false,"landing_page_url":"https://doaj.org/article/ea44e3dc25124a448bea57daefdb1c6e","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Global Energy Interconnection, Vol 1, Iss 3, Pp 344-351 (2018)","raw_type":"article"}],"best_oa_location":{"id":"mag:2936020144","doi":"https://doi.org/10.14171/j.2096-5117.gei.2018.03.005","is_oa":true,"landing_page_url":"https://www.sciencedirect.com/science/article/pii/S2096511718300458","pdf_url":null,"source":{"id":"https://openalex.org/S4210177181","display_name":"Global Energy Interconnection","issn_l":"2096-5117","issn":["2096-5117","2590-0358"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-d","jufo-1","norway-1","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Global Energy Interconnection","raw_type":null},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.5690000057220459,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/9","score":0.5378999710083008,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2398471955","https://openalex.org/W3149749252","https://openalex.org/W2514738066","https://openalex.org/W2390574857","https://openalex.org/W4414856430","https://openalex.org/W2898655040","https://openalex.org/W3025202557","https://openalex.org/W2971156354","https://openalex.org/W2081359495","https://openalex.org/W1996772045"],"abstract_inverted_index":{"HVDC":[0,12,30],"transfer":[1,44],"switches":[2,45],"are":[3],"used":[4],"in":[5,8,37,53],"different":[6],"locations":[7],"electrode":[9],"lines":[10],"of":[11,29,43,48,64,92],"transmission":[13,31],"systems":[14],"for":[15],"their":[16],"reconfigurations.":[17],"They":[18],"have":[19],"to":[20,25,35,79,83],"carry":[21,80],"and":[22,55,62,85],"commutate":[23],"currents":[24,28,81],"the":[26,38,60],"overload":[27],"systems,":[32],"which":[33],"increased":[34],"6,400A":[36],"past":[39],"years.":[40],"Common":[41],"designs":[42],"use":[46],"combinations":[47],"several":[49],"switching":[50,72],"units":[51,73],"connected":[52],"series":[54],"parallel.":[56],"This":[57],"paper":[58],"describes":[59],"design":[61],"development":[63],"a":[65],"new":[66],"DC":[67],"commutation":[68,90,102],"switch":[69],"with":[70],"two":[71],"only,":[74],"but":[75],"it":[76],"is":[77],"able":[78],"up":[82],"10,000A":[84,104],"has":[86],"an":[87],"actual":[88],"tested":[89],"capability":[91],"6,500":[93,100],"A.":[94],"Keywords:":[95],"HVDC,":[96],"Switch,":[97],"Passive":[98],"resonance,":[99],"A":[101],"current,":[103],"nominal":[105],"current":[106]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2936020144","counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2019-04-25T00:00:00"}