{"id":"https://openalex.org/W2932912178","doi":"https://doi.org/10.31940/logic.v19i1.1275","title":"Ground Fault Protection Using Open Break Delta Grounding Transformer in Ungrounded System","display_name":"Ground Fault Protection Using Open Break Delta Grounding Transformer in Ungrounded System","alternate_titles":[],"publication_year":2019,"publication_date":"2019-03-30","ids":{"openalex":"https://openalex.org/W2932912178","doi":"https://doi.org/10.31940/logic.v19i1.1275","mag":"2932912178"},"language":"en","primary_location":{"id":"doi:10.31940/logic.v19i1.1275","doi":"https://doi.org/10.31940/logic.v19i1.1275","is_oa":true,"landing_page_url":"https://doi.org/10.31940/logic.v19i1.1275","pdf_url":"http://ojs.pnb.ac.id/index.php/LOGIC/article/download/1275/986","source":{"id":"https://openalex.org/S4210172714","display_name":"Logic Jurnal Rancang Bangun dan Teknologi","issn_l":"1412-114X","issn":["1412-114X","2580-5649"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj","sinta-s3"],"host_organization":"https://openalex.org/P4310314916","host_organization_name":"Politeknik Negeri Bali","host_organization_lineage":["https://openalex.org/P4310314916"],"host_organization_lineage_names":["Politeknik Negeri Bali"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Logic : Jurnal Rancang Bangun dan Teknologi","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2932912178"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"http://ojs.pnb.ac.id/index.php/LOGIC/article/download/1275/986","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5001794687","display_name":"Supriyanto Suhono","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I4400008984","display_name":"Politeknik Negeri Bandung","ror":"https://ror.org/05v5br676","country_code":"ID","type":"education","lineage":["https://openalex.org/I4400008984"]}],"countries":["ID"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Supriyanto Suhono","raw_affiliation_strings":["Politeknik Negeri Bandung"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Politeknik Negeri Bandung","institution_ids":["https://openalex.org/I4400008984"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028073831","display_name":"Hari Purnama","type":null,"orcid":"https://orcid.org/0009-0005-6474-9840","observed_orcids":["https://orcid.org/0009-0005-6474-9840"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I4400008984","display_name":"Politeknik Negeri Bandung","ror":"https://ror.org/05v5br676","country_code":"ID","type":"education","lineage":["https://openalex.org/I4400008984"]}],"countries":["ID"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Hari Purnama","raw_affiliation_strings":["Politeknik Negeri Bandung"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Politeknik Negeri Bandung","institution_ids":["https://openalex.org/I4400008984"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5067828208","display_name":"Heri Budi Utomo","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I4400008984","display_name":"Politeknik Negeri Bandung","ror":"https://ror.org/05v5br676","country_code":"ID","type":"education","lineage":["https://openalex.org/I4400008984"]}],"countries":["ID"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Heri Budi Utomo","raw_affiliation_strings":["Politeknik Negeri Bandung"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Politeknik Negeri Bandung","institution_ids":["https://openalex.org/I4400008984"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4400008984"],"apc_list":null,"apc_paid":null,"fwci":0.3281,"has_fulltext":true,"cited_by_count":7,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.51667739,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":96},"biblio":{"volume":"19","issue":"1","first_page":"34","last_page":"34"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ground-fault-protection","display_name":"ground fault protection","score":0.9940000176429749},{"id":"https://openalex.org/keywords/ungrounded-systems","display_name":"ungrounded systems","score":0.7820000052452087},{"id":"https://openalex.org/keywords/distribution-power-systems","display_name":"distribution power systems","score":0.6399999856948853},{"id":"https://openalex.org/keywords/voltage-transformers","display_name":"voltage transformers","score":0.6079999804496765},{"id":"https://openalex.org/keywords/fault-location-detection","display_name":"fault location detection","score":0.8230000138282776},{"id":"https://openalex.org/keywords/single-line-to-ground-fault","display_name":"single-phase grounding fault","score":0.7149999737739563},{"id":"https://openalex.org/keywords/20-kv-distribution-network","display_name":"20 kV distribution network","score":0.6259999871253967}],"concepts":[{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.777647852897644},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.6827297210693359},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6207621693611145},{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.5752494931221008},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5687720775604248},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5498499870300293},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.45173579454421997},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.43418318033218384},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.42630085349082947},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2240460216999054},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.21736493706703186},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.31940/logic.v19i1.1275","doi":"https://doi.org/10.31940/logic.v19i1.1275","is_oa":true,"landing_page_url":"https://doi.org/10.31940/logic.v19i1.1275","pdf_url":"http://ojs.pnb.ac.id/index.php/LOGIC/article/download/1275/986","source":{"id":"https://openalex.org/S4210172714","display_name":"Logic Jurnal Rancang Bangun dan Teknologi","issn_l":"1412-114X","issn":["1412-114X","2580-5649"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj","sinta-s3"],"host_organization":"https://openalex.org/P4310314916","host_organization_name":"Politeknik Negeri Bali","host_organization_lineage":["https://openalex.org/P4310314916"],"host_organization_lineage_names":["Politeknik Negeri Bali"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Logic : Jurnal Rancang Bangun dan Teknologi","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:fbde07d146594181bc94456264f64384","doi":null,"is_oa":false,"landing_page_url":"https://doaj.org/article/fbde07d146594181bc94456264f64384","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Logic, Vol 19, Iss 1, Pp 34-40 (2019)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.31940/logic.v19i1.1275","doi":"https://doi.org/10.31940/logic.v19i1.1275","is_oa":true,"landing_page_url":"https://doi.org/10.31940/logic.v19i1.1275","pdf_url":"http://ojs.pnb.ac.id/index.php/LOGIC/article/download/1275/986","source":{"id":"https://openalex.org/S4210172714","display_name":"Logic Jurnal Rancang Bangun dan Teknologi","issn_l":"1412-114X","issn":["1412-114X","2580-5649"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj","sinta-s3"],"host_organization":"https://openalex.org/P4310314916","host_organization_name":"Politeknik Negeri Bali","host_organization_lineage":["https://openalex.org/P4310314916"],"host_organization_lineage_names":["Politeknik Negeri Bali"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Logic : Jurnal Rancang Bangun dan Teknologi","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.5378999710083008,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2932912178.pdf","grobid_xml":"https://content.openalex.org/works/W2932912178.grobid-xml"},"referenced_works_count":7,"referenced_works":["https://openalex.org/W1979256793","https://openalex.org/W2116577189","https://openalex.org/W2157342969","https://openalex.org/W2159431530","https://openalex.org/W2536106464","https://openalex.org/W2784241163","https://openalex.org/W7097719581"],"related_works":["https://openalex.org/W2138825910","https://openalex.org/W4392923218","https://openalex.org/W3208665918","https://openalex.org/W2784241163","https://openalex.org/W1587290408","https://openalex.org/W2081183657","https://openalex.org/W7097678368","https://openalex.org/W2804492556","https://openalex.org/W2536106464","https://openalex.org/W4249438050"],"abstract_inverted_index":{"One":[0,177],"of":[1,19,26,54,101,128,131,162,170,175,187],"the":[2,15,20,24,39,45,58,61,117,120,126,129,132,146],"most":[3],"common":[4],"and":[5,17,41,60,73,145,165,189,196],"difficult":[6],"problems":[7],"to":[8,93,108,125,136],"solve":[9],"in":[10,31,86],"distribution":[11,29],"power":[12,163],"systems":[13],"is":[14,97,113,142,151],"location":[16,81],"elimination":[18],"ground":[21,94,110,137],"fault.":[22],"For":[23],"study":[25],"an":[27,166],"electrical":[28],"network":[30],"ungrounded":[32],"system":[33,67],"operating":[34],"at":[35,139,149,184],"20":[36],"kV":[37],"on":[38,44,57,119],"primary":[40,59],"380":[42,55],"V":[43,56],"secondary.":[46,62],"The":[47,63,105],"model":[48],"uses":[49,69],"smaller":[50],"nominal":[51],"voltages":[52],"consisting":[53],"Ground":[64],"fault":[65,80,95,111,179],"protection":[66,180],"scheme":[68],"over":[70],"voltage":[71,84,121,138,190],"relays":[72],"open":[74],"break":[75],"delta":[76],"transformers,":[77],"whereas":[78],"for":[79,99,115],"detection":[82],"using":[83],"transformers":[85,191],"star":[87,88],"connections.The":[89],"highest":[90,133],"single":[91,106,134],"line":[92,107],"value":[96,112],"used":[98,114],"consideration":[100],"ballast":[102,157],"rating":[103],"selection.":[104],"lowest":[109,147],"setting":[116,169],"threshold":[118,168],"relay":[122],"(59N).":[123],"Referring":[124],"result":[127],"calculation":[130],"phase":[135,178],"point":[140,148,186],"1":[141],"144\u22201800":[143],"volts,":[144],"4":[150],"132\u22201800":[152],"volts.":[153],"A":[154],"200":[155],"ohm":[156],"impedance":[158],"with":[159,173],"150":[160],"watts":[161],"capacity,":[164],"overvoltage":[167],"120":[171],"volts":[172],"TDS":[174],"40.":[176],"mechanism":[181],"works":[182],"well":[183],"each":[185],"interference,":[188],"are":[192],"protected":[193],"from":[194],"overheating":[195],"damage.":[197]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2932912178","counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2}],"updated_date":"2026-11-25T09:40:18.809321","created_date":"2019-04-11T00:00:00"}
