{"id":"https://openalex.org/W2926257154","doi":"https://doi.org/10.1109/trpms.2019.2908219","title":"High-Resolution Radioluminescence Microscopy Image Reconstruction via Ionization Track Analysis","display_name":"High-Resolution Radioluminescence Microscopy Image Reconstruction via Ionization Track Analysis","publication_year":2019,"publication_date":"2019-03-29","ids":{"openalex":"https://openalex.org/W2926257154","doi":"https://doi.org/10.1109/trpms.2019.2908219","mag":"2926257154"},"language":"en","primary_location":{"id":"doi:10.1109/trpms.2019.2908219","doi":"https://doi.org/10.1109/trpms.2019.2908219","is_oa":false,"landing_page_url":"https://doi.org/10.1109/trpms.2019.2908219","pdf_url":null,"source":{"id":"https://openalex.org/S4210231342","display_name":"IEEE Transactions on Radiation and Plasma Medical Sciences","issn_l":"2469-7303","issn":["2469-7303","2469-7311"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-d","ki-jl-1","norway-1","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Radiation and Plasma Medical Sciences","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5020456403","display_name":"Sepideh Almasi","orcid":"https://orcid.org/0000-0001-7684-438X","observed_orcids":["https://orcid.org/0000-0001-7684-438X"]},"institutions":[{"id":"https://openalex.org/I97018004","display_name":"Stanford University","ror":"https://ror.org/00f54p054","country_code":"US","type":"education","lineage":["https://openalex.org/I97018004"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Sepideh Almasi","raw_affiliation_strings":["School of Medicine, Stanford University, Stanford, USA"],"raw_orcid":"https://orcid.org/0000-0001-7684-438X","affiliations":[{"raw_affiliation_string":"School of Medicine, Stanford University, Stanford, USA","institution_ids":["https://openalex.org/I97018004"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5062468106","display_name":"Guillem Pratx","orcid":"https://orcid.org/0000-0002-0247-6470","observed_orcids":["https://orcid.org/0000-0002-0247-6470"]},"institutions":[{"id":"https://openalex.org/I97018004","display_name":"Stanford University","ror":"https://ror.org/00f54p054","country_code":"US","type":"education","lineage":["https://openalex.org/I97018004"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Guillem Pratx","raw_affiliation_strings":["School of Medicine, Stanford University, Stanford, USA"],"raw_orcid":"https://orcid.org/0000-0002-0247-6470","affiliations":[{"raw_affiliation_string":"School of Medicine, Stanford University, Stanford, USA","institution_ids":["https://openalex.org/I97018004"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I97018004"],"apc_list":{"value":2045,"currency":"USD","value_usd":2045},"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.02939716,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"3","issue":"6","first_page":"660","last_page":"667"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11216","display_name":"Radiation Detection and Scintillator Technologies","score":0.7250999808311462,"subfield":{"id":"https://openalex.org/subfields/3108","display_name":"Radiation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11216","display_name":"Radiation Detection and Scintillator Technologies","score":0.7250999808311462,"subfield":{"id":"https://openalex.org/subfields/3108","display_name":"Radiation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10522","display_name":"Medical Imaging Techniques and Applications","score":0.1574999988079071,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10540","display_name":"Advanced Fluorescence Microscopy Techniques","score":0.03319999948143959,"subfield":{"id":"https://openalex.org/subfields/1304","display_name":"Biophysics"},"field":{"id":"https://openalex.org/fields/13","display_name":"Biochemistry, Genetics and Molecular Biology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/image-reconstruction","display_name":"image reconstruction","score":0.8889999985694885},{"id":"https://openalex.org/keywords/radiotracer-uptake","display_name":"radiotracer uptake","score":0.7400000095367432},{"id":"https://openalex.org/keywords/live-cell-imaging","display_name":"live-cell imaging","score":0.7160000205039978},{"id":"https://openalex.org/keywords/spatial-resolution-enhancement","display_name":"spatial resolution enhancement","score":0.8109999895095825},{"id":"https://openalex.org/keywords/signal-to-noise-ratio","display_name":"signal-to-noise ratio","score":0.8399999737739563}],"concepts":[{"id":"https://openalex.org/C8474884","wikidata":"https://www.wikidata.org/wiki/Q980416","display_name":"Radioluminescence","level":4,"score":0.8424966335296631},{"id":"https://openalex.org/C89992363","wikidata":"https://www.wikidata.org/wiki/Q5961558","display_name":"Track (disk drive)","level":2,"score":0.6373251080513},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6142948269844055},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.5595401525497437},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.540543258190155},{"id":"https://openalex.org/C198291218","wikidata":"https://www.wikidata.org/wiki/Q190382","display_name":"Ionization","level":3,"score":0.5326433181762695},{"id":"https://openalex.org/C147080431","wikidata":"https://www.wikidata.org/wiki/Q1074953","display_name":"Microscopy","level":2,"score":0.5297663807868958},{"id":"https://openalex.org/C205372480","wikidata":"https://www.wikidata.org/wiki/Q210521","display_name":"Image resolution","level":2,"score":0.52125483751297},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.5025341510772705},{"id":"https://openalex.org/C138268822","wikidata":"https://www.wikidata.org/wiki/Q1051925","display_name":"Resolution (logic)","level":2,"score":0.47854241728782654},{"id":"https://openalex.org/C89600930","wikidata":"https://www.wikidata.org/wiki/Q1423946","display_name":"Segmentation","level":2,"score":0.464020311832428},{"id":"https://openalex.org/C99498987","wikidata":"https://www.wikidata.org/wiki/Q2210247","display_name":"Noise (video)","level":3,"score":0.4474671483039856},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4143815040588379},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.39310991764068604},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.32236576080322266},{"id":"https://openalex.org/C102637530","wikidata":"https://www.wikidata.org/wiki/Q3078889","display_name":"Scintillation","level":3,"score":0.26621437072753906},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.2560562491416931},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.25041642785072327},{"id":"https://openalex.org/C115961682","wikidata":"https://www.wikidata.org/wiki/Q860623","display_name":"Image (mathematics)","level":2,"score":0.20269107818603516},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.10283058881759644},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.07592350244522095},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C145148216","wikidata":"https://www.wikidata.org/wiki/Q36496","display_name":"Ion","level":2,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/trpms.2019.2908219","doi":"https://doi.org/10.1109/trpms.2019.2908219","is_oa":false,"landing_page_url":"https://doi.org/10.1109/trpms.2019.2908219","pdf_url":null,"source":{"id":"https://openalex.org/S4210231342","display_name":"IEEE Transactions on Radiation and Plasma Medical Sciences","issn_l":"2469-7303","issn":["2469-7303","2469-7311"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-d","ki-jl-1","norway-1","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Radiation and Plasma Medical Sciences","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"sustainable_development_goals_aurora":[],"study_designs":[],"awards":[{"id":"https://openalex.org/G7239606446","display_name":"Postdoctoral Training in the Radiation Scinces","funder_award_id":"T32CA121940","funder_id":"https://openalex.org/F4320337351","funder_display_name":"National Cancer Institute"}],"funders":[{"id":"https://openalex.org/F4320332161","display_name":"National Institutes of Health","ror":"https://ror.org/01cwqze88"},{"id":"https://openalex.org/F4320337351","display_name":"National Cancer Institute","ror":"https://ror.org/040gcmg81"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W26112474","https://openalex.org/W1561442812","https://openalex.org/W1967442749","https://openalex.org/W1973293661","https://openalex.org/W1984657815","https://openalex.org/W1999693989","https://openalex.org/W2021470950","https://openalex.org/W2028897202","https://openalex.org/W2043946038","https://openalex.org/W2045428587","https://openalex.org/W2050841253","https://openalex.org/W2057545963","https://openalex.org/W2064437293","https://openalex.org/W2107500316","https://openalex.org/W2108855378","https://openalex.org/W2112443467","https://openalex.org/W2118107482","https://openalex.org/W2166034073","https://openalex.org/W2214864214","https://openalex.org/W2545545604","https://openalex.org/W2594811343","https://openalex.org/W2607141745","https://openalex.org/W2800332668"],"related_works":["https://openalex.org/W1999693989","https://openalex.org/W7099949211","https://openalex.org/W7155410756","https://openalex.org/W2247563709","https://openalex.org/W3041889695","https://openalex.org/W4400653140","https://openalex.org/W2528638177","https://openalex.org/W3011972531","https://openalex.org/W2938183577","https://openalex.org/W4417470873"],"abstract_inverted_index":{"Radioluminescence":[0],"microscopy":[1],"(RLM)":[2],"is":[3,144],"a":[4,31,51,118],"newly":[5],"developed":[6,50],"paradigm":[7],"for":[8,177],"visualizing":[9],"radiotracer":[10],"uptake":[11],"in":[12,62],"live":[13],"cells.":[14],"High-resolution":[15],"images":[16,61],"are":[17,110,175],"obtained":[18],"by":[19],"capturing":[20],"the":[21,36,41,44,57,95,168,181],"scintillation":[22],"of":[23,43,59,94,121,136],"individual":[24],"beta":[25],"particles":[26],"emitted":[27],"from":[28],"cells":[29],"using":[30],"low-light":[32],"microscope":[33],"and":[34,68,85,103,117,141,160],"processing":[35],"resulting":[37],"frames":[38],"to":[39,82,112,125,146,167],"estimate":[40],"location":[42],"corresponding":[45],"decay":[46],"events.":[47],"We":[48],"have":[49],"novel":[52],"reconstruction":[53],"method":[54,76,138],"that":[55],"enhances":[56],"quality":[58],"RLM":[60],"many":[63],"aspects,":[64],"including":[65],"spatial":[66,158],"resolution":[67],"sensitivity,":[69],"with":[70,98,150],"no":[71,99],"hardware":[72],"modifications.":[73],"The":[74,88,172],"proposed":[75],"requires":[77],"minimal":[78],"user":[79,100],"interaction":[80],"leading":[81],"more":[83],"accurate":[84],"reproducible":[86],"results.":[87],"major":[89],"improvements":[90],"include":[91],"automated":[92],"segmentation":[93,164],"ionization":[96,105,122],"tracks":[97],"input":[101],"required":[102],"enhanced":[104],"sourcepoint":[106],"localization.":[107],"These":[108],"operations":[109],"designed":[111],"robustly":[113],"handle":[114],"image":[115],"artifacts":[116],"wide":[119],"variety":[120],"track":[123,163],"shapes":[124],"guarantee":[126],"high":[127],"performance":[128,173],"across":[129],"datasets":[130,143,179],"collected":[131],"under":[132],"varying":[133],"conditions.":[134],"Implementation":[135],"this":[137],"on":[139],"real":[140],"synthetic":[142],"shown":[145],"provide":[147],"cell":[148],"reconstructions":[149],"14%":[151],"higher":[152,162],"signalto-noise":[153],"ratio":[154],"(SNR),":[155],"18%":[156],"better":[157],"resolution,":[159],"20%":[161],"sensitivity":[165],"compared":[166],"currently":[169],"used":[170],"algorithm.":[171],"measures":[174],"consistent":[176],"various":[178],"confirming":[180],"method's":[182],"reliability.":[183]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-10-28T10:33:24.094632","created_date":"2019-04-11T00:00:00"}
