{"id":"https://openalex.org/W2921068338","doi":"https://doi.org/10.11591/ijece.v9i3.pp1506-1513","title":"Relevance vector machine based fault classification in wind energy conversion system","display_name":"Relevance vector machine based fault classification in wind energy conversion system","publication_year":2019,"publication_date":"2019-04-20","ids":{"openalex":"https://openalex.org/W2921068338","doi":"https://doi.org/10.11591/ijece.v9i3.pp1506-1513","mag":"2921068338"},"language":"en","primary_location":{"id":"doi:10.11591/ijece.v9i3.pp1506-1513","doi":"https://doi.org/10.11591/ijece.v9i3.pp1506-1513","is_oa":true,"landing_page_url":"https://doi.org/10.11591/ijece.v9i3.pp1506-1513","pdf_url":"http://ijece.iaescore.com/index.php/IJECE/article/download/13245/12304","source":{"id":"https://openalex.org/S2764532672","display_name":"International Journal of Electrical and Computer Engineering (IJECE)","issn_l":"2088-8708","issn":["2088-8708"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310315009","host_organization_name":"Institute of Advanced Engineering and Science (IAES)","host_organization_lineage":["https://openalex.org/P4310315009"],"host_organization_lineage_names":["Institute of Advanced Engineering and Science (IAES)"],"type":"journal"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Electrical and Computer Engineering (IJECE)","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"http://ijece.iaescore.com/index.php/IJECE/article/download/13245/12304","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5104154419","display_name":"S. N. Rekha","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I65674248","display_name":"Visvesvaraya Technological University","ror":"https://ror.org/00ha14p11","country_code":"IN","type":"education","lineage":["https://openalex.org/I65674248"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Rekha S. N.","raw_affiliation_strings":["Sapthagiri College of Engineering"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sapthagiri College of Engineering","institution_ids":["https://openalex.org/I65674248"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5016992919","display_name":"P. Aruna Jeyanthy","orcid":"https://orcid.org/0000-0002-0667-5047","observed_orcids":["https://orcid.org/0000-0002-0667-5047"]},"institutions":[{"id":"https://openalex.org/I98499257","display_name":"Kalasalingam Academy of Research and Education","ror":"https://ror.org/04fm2fn75","country_code":"IN","type":"education","lineage":["https://openalex.org/I98499257"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"P. Aruna Jeyanthy","raw_affiliation_strings":["Kalasalingam Academy of Research and Education (KARE)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Kalasalingam Academy of Research and Education (KARE)","institution_ids":["https://openalex.org/I98499257"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5018063453","display_name":"D. Devaraj","orcid":"https://orcid.org/0000-0002-0382-0050","observed_orcids":["https://orcid.org/0000-0002-0382-0050"]},"institutions":[{"id":"https://openalex.org/I98499257","display_name":"Kalasalingam Academy of Research and Education","ror":"https://ror.org/04fm2fn75","country_code":"IN","type":"education","lineage":["https://openalex.org/I98499257"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"D. Devaraj","raw_affiliation_strings":["Kalasalingam Academy of Research and Education (KARE)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Kalasalingam Academy of Research and Education (KARE)","institution_ids":["https://openalex.org/I98499257"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4154,"has_fulltext":true,"cited_by_count":3,"citation_normalized_percentile":{"value":0.59775493,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":"9","issue":"3","first_page":"1506","last_page":"1506"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9458000063896179,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9458000063896179,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.049300000071525574,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.001500000013038516,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/relevance-vector-machine","display_name":"relevance vector machine","score":0.9950000047683716},{"id":"https://openalex.org/keywords/fault-classification","display_name":"fault classification","score":0.9459999799728394},{"id":"https://openalex.org/keywords/wind-energy-conversion-system","display_name":"wind energy conversion system","score":0.9509999752044678},{"id":"https://openalex.org/keywords/fault-detection","display_name":"fault detection","score":0.8149999976158142},{"id":"https://openalex.org/keywords/multiclass-classification","display_name":"multi-class classification","score":0.8190000057220459},{"id":"https://openalex.org/keywords/structural-risk-minimization","display_name":"structural risk minimization","score":0.8460000157356262},{"id":"https://openalex.org/keywords/gaussian-kernel","display_name":"Gaussian kernel","score":0.9850000143051147},{"id":"https://openalex.org/keywords/sensor-faults","display_name":"sensor faults","score":0.7440000176429749},{"id":"https://openalex.org/keywords/actuator-faults","display_name":"actuator faults","score":0.9739999771118164},{"id":"https://openalex.org/keywords/online-fault-detection","display_name":"real-time fault detection","score":0.6710000038146973},{"id":"https://openalex.org/keywords/training-duration","display_name":"training duration","score":0.7210000157356262}],"concepts":[{"id":"https://openalex.org/C14948415","wikidata":"https://www.wikidata.org/wiki/Q7310972","display_name":"Relevance vector machine","level":3,"score":0.7518332004547119},{"id":"https://openalex.org/C185798385","wikidata":"https://www.wikidata.org/wiki/Q1161707","display_name":"Benchmark (surveying)","level":2,"score":0.7188145518302917},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7158812284469604},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.6373107433319092},{"id":"https://openalex.org/C154507838","wikidata":"https://www.wikidata.org/wiki/Q7625053","display_name":"Structural risk minimization","level":3,"score":0.626453161239624},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.6013425588607788},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5890287756919861},{"id":"https://openalex.org/C12267149","wikidata":"https://www.wikidata.org/wiki/Q282453","display_name":"Support vector machine","level":2,"score":0.5373526811599731},{"id":"https://openalex.org/C74193536","wikidata":"https://www.wikidata.org/wiki/Q574844","display_name":"Kernel (algebra)","level":2,"score":0.4604725241661072},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.41850125789642334},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.4042947590351105},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.33989524841308594},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.25576114654541016},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1677636206150055},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.11004781723022461},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.07082274556159973},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C13280743","wikidata":"https://www.wikidata.org/wiki/Q131089","display_name":"Geodesy","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.0},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.11591/ijece.v9i3.pp1506-1513","doi":"https://doi.org/10.11591/ijece.v9i3.pp1506-1513","is_oa":true,"landing_page_url":"https://doi.org/10.11591/ijece.v9i3.pp1506-1513","pdf_url":"http://ijece.iaescore.com/index.php/IJECE/article/download/13245/12304","source":{"id":"https://openalex.org/S2764532672","display_name":"International Journal of Electrical and Computer Engineering (IJECE)","issn_l":"2088-8708","issn":["2088-8708"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310315009","host_organization_name":"Institute of Advanced Engineering and Science (IAES)","host_organization_lineage":["https://openalex.org/P4310315009"],"host_organization_lineage_names":["Institute of Advanced Engineering and Science (IAES)"],"type":"journal"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Electrical and Computer Engineering (IJECE)","raw_type":"journal-article"},{"id":"pmh:oai:zenodo.org:4060636","doi":null,"is_oa":true,"landing_page_url":"https://zenodo.org/record/4060636","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Journal of Electrical and Computer Engineering (IJECE) 9(3) 1506-1513","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"doi:10.11591/ijece.v9i3.pp1506-1513","doi":"https://doi.org/10.11591/ijece.v9i3.pp1506-1513","is_oa":true,"landing_page_url":"https://doi.org/10.11591/ijece.v9i3.pp1506-1513","pdf_url":"http://ijece.iaescore.com/index.php/IJECE/article/download/13245/12304","source":{"id":"https://openalex.org/S2764532672","display_name":"International Journal of Electrical and Computer Engineering (IJECE)","issn_l":"2088-8708","issn":["2088-8708"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310315009","host_organization_name":"Institute of Advanced Engineering and Science (IAES)","host_organization_lineage":["https://openalex.org/P4310315009"],"host_organization_lineage_names":["Institute of Advanced Engineering and Science (IAES)"],"type":"journal"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Electrical and Computer Engineering (IJECE)","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.5690000057220459}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2921068338.pdf","grobid_xml":"https://content.openalex.org/works/W2921068338.grobid-xml"},"referenced_works_count":14,"referenced_works":["https://openalex.org/W1508838451","https://openalex.org/W1851258275","https://openalex.org/W1958544680","https://openalex.org/W1988499271","https://openalex.org/W2020174716","https://openalex.org/W2024503684","https://openalex.org/W2025052407","https://openalex.org/W2030049536","https://openalex.org/W2080291579","https://openalex.org/W2109332719","https://openalex.org/W2213981763","https://openalex.org/W2289657881","https://openalex.org/W2767637763","https://openalex.org/W2787868457"],"related_works":["https://openalex.org/W2979980434","https://openalex.org/W4233843332","https://openalex.org/W4414883595","https://openalex.org/W2930606452","https://openalex.org/W3000379898","https://openalex.org/W3165290795","https://openalex.org/W3192448143","https://openalex.org/W3100567585","https://openalex.org/W4288773407","https://openalex.org/W2253965422"],"abstract_inverted_index":{"This":[0],"Paper":[1],"is":[2,47,73,99,110,115,127],"an":[3,119],"attempt":[4],"to":[5,154],"develop":[6],"the":[7,11,22,65,77,85,97,107,113,131,135,139,146],"multiclass":[8],"classification":[9,53],"in":[10,64,102,138,158],"Benchmark":[12],"fault":[13,69,121,136,149],"model":[14,133],"applied":[15],"on":[16,84,118,130],"wind":[17],"energy":[18],"conversion":[19],"system":[20],"using":[21,76,82],"relevance":[23],"vector":[24],"machine":[25],"(RVM).":[26],"The":[27,44,52,91,141],"RVM":[28,78],"could":[29],"apply":[30],"a":[31,37,103],"structural":[32],"risk":[33],"minimization":[34],"by":[35],"introducing":[36],"proper":[38],"kernel":[39],"for":[40,49,134],"training":[41,92,98,161],"and":[42,57,62,71,106,152,163],"testing.":[43],"Gaussian":[45],"Kernel":[46],"used":[48],"this":[50],"purpose.":[51],"of":[54,160],"sensor,":[55],"process":[56],"actuators":[58],"faults":[59],"are":[60,143],"observed":[61],"classified":[63],"implementation.":[66],"Training":[67],"different":[68],"condition":[70],"testing":[72,114],"carried":[74,80,100,116,128],"out":[75,81,101,117,129],"implementation":[79,126],"Matlab":[83,124],"Wind":[86],"Energy":[87],"Conversion":[88],"System":[89],"(WECS).":[90],"time":[93,162],"becomes":[94],"important":[95],"while":[96,112],"bigger":[104],"WECS,":[105],"hardware":[108,164],"feasibility":[109],"prime":[111],"online":[120],"detection":[122,137,150],"scenario.":[123],"based":[125],"benchmark":[132],"WECS.":[140],"results":[142],"compared":[144],"with":[145],"previously":[147],"implemented":[148],"technique":[151],"found":[153],"be":[155],"performing":[156],"better":[157],"terms":[159],"feasibility.":[165]},"counts_by_year":[{"year":2021,"cited_by_count":2},{"year":2019,"cited_by_count":1}],"updated_date":"2026-09-26T08:19:03.415552","created_date":"2019-03-22T00:00:00"}
