{"id":"https://openalex.org/W2918697181","doi":"https://doi.org/10.1088/1755-1315/238/1/012082","title":"Energy efficiency evaluation of multiple split-system air conditioners with unbalanced load operation for building energy simulation","display_name":"Energy efficiency evaluation of multiple split-system air conditioners with unbalanced load operation for building energy simulation","publication_year":2019,"publication_date":"2019-03-04","ids":{"openalex":"https://openalex.org/W2918697181","doi":"https://doi.org/10.1088/1755-1315/238/1/012082","mag":"2918697181"},"language":"en","primary_location":{"id":"doi:10.1088/1755-1315/238/1/012082","doi":"https://doi.org/10.1088/1755-1315/238/1/012082","is_oa":true,"landing_page_url":"https://doi.org/10.1088/1755-1315/238/1/012082","pdf_url":"https://iopscience.iop.org/article/10.1088/1755-1315/238/1/012082/pdf","source":{"id":"https://openalex.org/S4210195883","display_name":"IOP Conference Series Earth and Environmental Science","issn_l":"1755-1315","issn":["1755-1315","1755-1307"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":["norway-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IOP Conference Series: Earth and Environmental Science","raw_type":"journal-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://iopscience.iop.org/article/10.1088/1755-1315/238/1/012082/pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5070633184","display_name":"Masato Miyata","orcid":"https://orcid.org/0000-0001-7853-3120","observed_orcids":["https://orcid.org/0000-0001-7853-3120"]},"institutions":[{"id":"https://openalex.org/I4210142332","display_name":"National Institute for Land and Infrastructure Management","ror":"https://ror.org/044bxz342","country_code":"JP","type":"government","lineage":["https://openalex.org/I1308952385","https://openalex.org/I4210142332"]}],"countries":["JP"],"is_corresponding":true,"raw_author_name":"M Miyata","raw_affiliation_strings":["Senior Researcher, National Institute for Land and Infrastructure Management, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Senior Researcher, National Institute for Land and Infrastructure Management, Japan","institution_ids":["https://openalex.org/I4210142332"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5070633184"],"corresponding_institution_ids":["https://openalex.org/I4210142332"],"apc_list":null,"apc_paid":null,"fwci":0.5097,"has_fulltext":true,"cited_by_count":1,"citation_normalized_percentile":{"value":0.51331431,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":"238","issue":null,"first_page":"012082","last_page":"012082"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.6195999979972839,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.6195999979972839,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.37400001287460327,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.0038999998942017555,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/energy-efficiency","display_name":"energy efficiency","score":0.753000020980835},{"id":"https://openalex.org/keywords/part-load-operation","display_name":"off-design operation","score":0.8629999756813049},{"id":"https://openalex.org/keywords/building-energy-simulation","display_name":"building energy simulation","score":0.8100000023841858},{"id":"https://openalex.org/keywords/small-and-medium-sized-buildings","display_name":"small and medium-sized buildings","score":0.7860000133514404},{"id":"https://openalex.org/keywords/energy-loss","display_name":"energy loss","score":0.3779999911785126}],"concepts":[{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.7009397745132446},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.7006206512451172},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.6113015413284302},{"id":"https://openalex.org/C2781099182","wikidata":"https://www.wikidata.org/wiki/Q24963825","display_name":"Cooling load","level":3,"score":0.5959576368331909},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5735790133476257},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.5462585687637329},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5084692239761353},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4841800034046173},{"id":"https://openalex.org/C2989353520","wikidata":"https://www.wikidata.org/wiki/Q2419918","display_name":"Heat load","level":2,"score":0.4669334292411804},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4544546604156494},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.36664068698883057},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.35508644580841064},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2493833303451538},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.17705494165420532},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.13919273018836975},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1324598491191864},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.11673480272293091},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1088/1755-1315/238/1/012082","doi":"https://doi.org/10.1088/1755-1315/238/1/012082","is_oa":true,"landing_page_url":"https://doi.org/10.1088/1755-1315/238/1/012082","pdf_url":"https://iopscience.iop.org/article/10.1088/1755-1315/238/1/012082/pdf","source":{"id":"https://openalex.org/S4210195883","display_name":"IOP Conference Series Earth and Environmental Science","issn_l":"1755-1315","issn":["1755-1315","1755-1307"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":["norway-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IOP Conference Series: Earth and Environmental Science","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1088/1755-1315/238/1/012082","doi":"https://doi.org/10.1088/1755-1315/238/1/012082","is_oa":true,"landing_page_url":"https://doi.org/10.1088/1755-1315/238/1/012082","pdf_url":"https://iopscience.iop.org/article/10.1088/1755-1315/238/1/012082/pdf","source":{"id":"https://openalex.org/S4210195883","display_name":"IOP Conference Series Earth and Environmental Science","issn_l":"1755-1315","issn":["1755-1315","1755-1307"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":["norway-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IOP Conference Series: Earth and Environmental Science","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9090999960899353},{"id":"https://metadata.un.org/sdg/13","display_name":"Climate action","score":0.5351999998092651}],"study_designs":[],"awards":[{"id":"https://openalex.org/G5611226226","display_name":"Energy Efficiency Evaluation for VRF System with Unbalanced Load Operation","funder_award_id":"17K18351","funder_id":"https://openalex.org/F4320334764","funder_display_name":"Japan Society for the Promotion of Science"}],"funders":[{"id":"https://openalex.org/F4320334764","display_name":"Japan Society for the Promotion of Science","ror":"https://ror.org/00hhkn466"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2918697181.pdf","grobid_xml":"https://content.openalex.org/works/W2918697181.grobid-xml"},"referenced_works_count":1,"referenced_works":["https://openalex.org/W4255310704"],"related_works":["https://openalex.org/W4237996307","https://openalex.org/W2084236036","https://openalex.org/W1566252155","https://openalex.org/W50356485","https://openalex.org/W2387236657","https://openalex.org/W2036843564","https://openalex.org/W2648395667","https://openalex.org/W2385733385","https://openalex.org/W4241326074","https://openalex.org/W2019019758"],"abstract_inverted_index":{"The":[0,146],"number":[1],"of":[2,29,86,105,115,129,156,160,200,218],"buildings":[3,107],"that":[4,110,126,227,237,251,259],"adopt":[5],"the":[6,25,30,59,65,87,93,102,116,120,127,138,153,161,169,177,184,189,198,201,206,215,219,238,252],"multiple":[7,31,143,220,229],"split-system":[8,221],"air":[9],"conditioners":[10],"is":[11,55,112,132,166,192],"increasing,":[12],"especially":[13],"for":[14],"small":[15],"and":[16,63,108,232,249],"medium-sized":[17],"buildings.":[18],"Many":[19],"researches":[20],"have":[21,78,100],"been":[22],"done":[23],"on":[24,82,214],"energy":[26,73,84,208,216,245],"consumption":[27,85],"performance":[28,49,62,67],"split-system,":[32],"but":[33,176],"there":[34,111],"are":[35,163],"still":[36],"many":[37],"unclear":[38],"points":[39],"about":[40,243],"its":[41],"actual":[42,106],"performance,":[43],"in":[44,137,223,247],"particularly,":[45],"with":[46],"regard":[47],"to":[48,57,91,134,149,180,205],"under":[50,95],"partial":[51,60,96],"load":[52,61,97,122,204,240,263],"condition.":[53],"It":[54],"important":[56],"understand":[58],"set":[64],"reliable":[66],"characteristics":[68],"when":[69,152,183],"we":[70,99],"perform":[71],"building":[72],"simulation":[74],"because":[75],"it":[76],"will":[77],"a":[79,113],"significant":[80],"influence":[81,199],"annual":[83],"system.":[88],"In":[89],"order":[90],"clarify":[92],"efficiency":[94,117,147,178,217],"condition,":[98],"analysed":[101],"measurement":[103],"data":[104,213],"found":[109,236],"range":[114,131],"even":[118],"at":[119],"same":[121,167],"ratio.":[123],"We":[124,210,235],"assume":[125],"cause":[128],"this":[130],"due":[133],"bias":[135],"(unbalance)":[136],"heat":[139,154,185,203,262],"amount":[140,155,186],"handled":[141,187],"by":[142,173,188],"indoor":[144,158,190,253],"units.":[145],"tends":[148,179],"be":[150,181,256],"higher":[151],"all":[157],"units":[159,191,254],"system":[162,207],"equal,":[164],"which":[165],"as":[168],"test":[170],"condition":[171],"specified":[172],"ISO":[174],"15042:2017,":[175],"lower":[182],"highly":[193],"unbalanced.":[194],"This":[195],"research":[196],"clarifies":[197],"unbalanced":[202,239,261],"efficiency.":[209],"measured":[211],"fundamental":[212],"air-conditioner":[222],"an":[224],"experimental":[225],"facility":[226],"connects":[228],"constant":[230],"temperature":[231],"humidity":[233],"chambers.":[234],"operation":[241],"caused":[242],"20%":[244],"loss":[246],"maximum":[248],"concluded":[250],"should":[255],"arranged":[257],"so":[258],"extreme":[260],"does":[264],"not":[265],"occur.":[266]},"counts_by_year":[{"year":2020,"cited_by_count":1}],"updated_date":"2026-08-05T07:39:15.569665","created_date":"2019-03-11T00:00:00"}
