{"id":"https://openalex.org/W2913695845","doi":"https://doi.org/10.1109/mepcon.2018.8635237","title":"DC Pole to Pole Short Circuit Fault Analysis in VSC-HVDC Transmission System","display_name":"DC Pole to Pole Short Circuit Fault Analysis in VSC-HVDC Transmission System","publication_year":2018,"publication_date":"2018-12-01","ids":{"openalex":"https://openalex.org/W2913695845","doi":"https://doi.org/10.1109/mepcon.2018.8635237","mag":"2913695845"},"language":"en","primary_location":{"id":"doi:10.1109/mepcon.2018.8635237","doi":"https://doi.org/10.1109/mepcon.2018.8635237","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mepcon.2018.8635237","pdf_url":null,"source":{"id":"https://openalex.org/S4363608303","display_name":"International Middle East Power Systems Conference (MEPCON)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 Twentieth International Middle East Power Systems Conference (MEPCON)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5082294806","display_name":"Sobhy Serry Dessouky","orcid":"https://orcid.org/0000-0003-2196-723X","observed_orcids":["https://orcid.org/0000-0003-2196-723X"]},"institutions":[{"id":"https://openalex.org/I88017793","display_name":"Port Said University","ror":"https://ror.org/01vx5yq44","country_code":"EG","type":"education","lineage":["https://openalex.org/I88017793"]}],"countries":["EG"],"is_corresponding":false,"raw_author_name":"Sobhy S. Dessouky","raw_affiliation_strings":["Department of Electrical Engineering, Port said University, Port said, Egypt"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Port said University, Port said, Egypt","institution_ids":["https://openalex.org/I88017793"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5032511065","display_name":"Mahmoud Fawzi","orcid":"https://orcid.org/0000-0002-6485-3163","observed_orcids":["https://orcid.org/0000-0002-6485-3163"]},"institutions":[{"id":"https://openalex.org/I88017793","display_name":"Port Said University","ror":"https://ror.org/01vx5yq44","country_code":"EG","type":"education","lineage":["https://openalex.org/I88017793"]}],"countries":["EG"],"is_corresponding":false,"raw_author_name":"M. Fawzi","raw_affiliation_strings":["Department of Electrical Engineering, Port said University, Port said, Egypt"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Port said University, Port said, Egypt","institution_ids":["https://openalex.org/I88017793"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109372775","display_name":"Hamed Anwer Ibrahim","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I130009713","display_name":"Suez University","ror":"https://ror.org/00ndhrx30","country_code":"EG","type":"education","lineage":["https://openalex.org/I130009713"]}],"countries":["EG"],"is_corresponding":false,"raw_author_name":"Hamed A. Ibrahim","raw_affiliation_strings":["Electrical Department, Suez University, Suez, Egypt"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Department, Suez University, Suez, Egypt","institution_ids":["https://openalex.org/I130009713"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5012500871","display_name":"Nagwa F. Ibrahim","orcid":"https://orcid.org/0000-0003-3978-7245","observed_orcids":["https://orcid.org/0000-0003-3978-7245"]},"institutions":[{"id":"https://openalex.org/I130009713","display_name":"Suez University","ror":"https://ror.org/00ndhrx30","country_code":"EG","type":"education","lineage":["https://openalex.org/I130009713"]}],"countries":["EG"],"is_corresponding":false,"raw_author_name":"Nagwa F. Ibrahim","raw_affiliation_strings":["Electrical Department, Suez University, Suez, Egypt"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Department, Suez University, Suez, Egypt","institution_ids":["https://openalex.org/I130009713"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":3.2027,"has_fulltext":false,"cited_by_count":24,"citation_normalized_percentile":{"value":0.93510959,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"900","last_page":"904"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/vsc-hvdc","display_name":"VSC-HVDC","score":0.9890000224113464},{"id":"https://openalex.org/keywords/dc-line-faults","display_name":"DC line faults","score":0.7049999833106995},{"id":"https://openalex.org/keywords/fault-behavior","display_name":"fault behavior","score":0.5389999747276306},{"id":"https://openalex.org/keywords/fault-clearing","display_name":"fault clearance","score":0.8999999761581421},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"fault detection and isolation","score":0.8130000233650208},{"id":"https://openalex.org/keywords/submarine-cables","display_name":"submarine cables","score":0.7609999775886536},{"id":"https://openalex.org/keywords/overhead-transmission-lines","display_name":"overhead transmission lines","score":0.6729999780654907},{"id":"https://openalex.org/keywords/system-reliability","display_name":"system reliability","score":0.6489999890327454}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6521672010421753},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5984845161437988},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.5648946762084961},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5081229209899902},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.49784040451049805},{"id":"https://openalex.org/C7904685","wikidata":"https://www.wikidata.org/wiki/Q2356943","display_name":"HVDC converter station","level":3,"score":0.4953128397464752},{"id":"https://openalex.org/C2780705257","wikidata":"https://www.wikidata.org/wiki/Q5636221","display_name":"HVDC converter","level":4,"score":0.4947316348552704},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4792056977748871},{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.46257972717285156},{"id":"https://openalex.org/C2779960059","wikidata":"https://www.wikidata.org/wiki/Q7113681","display_name":"Overhead (engineering)","level":2,"score":0.44651851058006287},{"id":"https://openalex.org/C144655898","wikidata":"https://www.wikidata.org/wiki/Q1161128","display_name":"Voltage source","level":3,"score":0.4440646469593048},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.4391987919807434},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4313860535621643},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.43066802620887756},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.4101703464984894},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.403503954410553},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.39025524258613586},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.38543522357940674},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.34176504611968994},{"id":"https://openalex.org/C2776620479","wikidata":"https://www.wikidata.org/wiki/Q159241","display_name":"Direct current","level":3,"score":0.27017414569854736},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07665479183197021},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/mepcon.2018.8635237","doi":"https://doi.org/10.1109/mepcon.2018.8635237","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mepcon.2018.8635237","pdf_url":null,"source":{"id":"https://openalex.org/S4363608303","display_name":"International Middle East Power Systems Conference (MEPCON)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 Twentieth International Middle East Power Systems Conference (MEPCON)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.5378999710083008}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W65006491","https://openalex.org/W326226202","https://openalex.org/W2071333862","https://openalex.org/W2257269774","https://openalex.org/W2515563710","https://openalex.org/W2558933202"],"related_works":["https://openalex.org/W4210769039","https://openalex.org/W2261088818","https://openalex.org/W4312742485","https://openalex.org/W3158597070","https://openalex.org/W2179317361","https://openalex.org/W3198581392","https://openalex.org/W2791159912","https://openalex.org/W4390418565","https://openalex.org/W4226383642","https://openalex.org/W2608570864"],"abstract_inverted_index":{"Voltage":[0,4],"Source":[1],"Converter":[2],"High":[3],"Direct":[5],"Current":[6],"(VSC-HVDC)":[7],"transmission":[8,16,58,80],"technology":[9],"is":[10],"widely":[11],"used":[12],"in":[13,49,55,61],"electrical":[14],"power":[15],"over":[17],"very":[18,97],"long":[19],"distances.":[20],"Those":[21],"systems":[22],"are":[23,47,96],"subjected":[24],"to":[25,77,83,99,109,138],"different":[26,66],"types":[27],"of":[28],"faults":[29,46],"that":[30],"have":[31],"an":[32],"effect":[33],"on":[34],"the":[35,41,71,79,85,101,125,129,140],"electricity":[36],"deliver":[37],"continuity":[38],"and":[39,64,82,92],"reduce":[40],"device":[42],"reliability.":[43,103],"DC":[44,107],"line":[45,81],"public":[48],"HVDC":[50],"systems,":[51],"it":[52],"may":[53],"occur":[54],"either":[56],"overhead":[57],"lines":[59],"or":[60],"submarine":[62],"cables":[63],"with":[65],"configurations.":[67],"In":[68,104],"such":[69],"faults,":[70],"converter":[72],"stations":[73],"must":[74],"be":[75],"blocked":[76],"isolate":[78],"shield":[84],"electronic":[86],"switches.":[87],"Therefore,":[88],"fault":[89,113,119,126,130],"detection,":[90],"isolation":[91],"system":[93,102],"restoring":[94],"techniques":[95],"important":[98],"development":[100],"this":[105],"paper,":[106],"pole":[108,110],"short":[111],"circuit":[112],"has":[114,121,135],"been":[115,122,136],"carefully":[116],"studied.":[117],"The":[118],"behavior":[120],"discussed":[123],"from":[124],"moment":[127],"until":[128],"clearance.":[131],"A":[132],"Matlab-Simulink":[133],"model":[134],"built":[137],"verify":[139],"mathematical":[141],"analysis.":[142]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":2}],"updated_date":"2026-10-26T11:51:55.731654","created_date":"2019-02-21T00:00:00"}
