{"id":"https://openalex.org/W2906825899","doi":"https://doi.org/10.1016/j.enconman.2018.12.016","title":"Sensitivity analysis of supercritical CO2 power cycle energy and exergy efficiencies regarding cycle component efficiencies for concentrating solar power","display_name":"Sensitivity analysis of supercritical CO2 power cycle energy and exergy efficiencies regarding cycle component efficiencies for concentrating solar power","alternate_titles":[],"publication_year":2019,"publication_date":"2019-01-05","ids":{"openalex":"https://openalex.org/W2906825899","doi":"https://doi.org/10.1016/j.enconman.2018.12.016","mag":"2906825899"},"language":"en","primary_location":{"id":"doi:10.1016/j.enconman.2018.12.016","doi":"https://doi.org/10.1016/j.enconman.2018.12.016","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.enconman.2018.12.016","pdf_url":null,"source":{"id":"https://openalex.org/S105637730","display_name":"Energy Conversion and Management","issn_l":"0196-8904","issn":["0196-8904","1879-2227"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-200","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Conversion and Management","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2906825899"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5072319394","display_name":"David Novales","orcid":"https://orcid.org/0000-0002-9311-6672","observed_orcids":["https://orcid.org/0000-0002-9311-6672"]},"institutions":[{"id":"https://openalex.org/I169108374","display_name":"University of the Basque Country","ror":"https://ror.org/000xsnr85","country_code":"ES","type":"education","lineage":["https://openalex.org/I169108374"]},{"id":"https://openalex.org/I2800916530","display_name":"Sener (Spain)","ror":"https://ror.org/03rjwv512","country_code":"ES","type":"company","lineage":["https://openalex.org/I2800916530"]}],"countries":["ES"],"is_corresponding":true,"raw_author_name":"D. Novales","raw_affiliation_strings":["Department of Mechanical Engineering, SENER Ingenier\u00eda y Sistemas S.A., Avda. Zugazarte 56, 48930 Getxo, Spain","Department of Thermal Engineering, Faculty of Engineering of Bilbao, University of the Basque Country (UPV/EHU), Alda. Urquijo s/n, 48013 Bilbao, Spain"],"raw_orcid":"https://orcid.org/0000-0002-9311-6672","affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, SENER Ingenier\u00eda y Sistemas S.A., Avda. Zugazarte 56, 48930 Getxo, Spain","institution_ids":["https://openalex.org/I2800916530"]},{"raw_affiliation_string":"Department of Thermal Engineering, Faculty of Engineering of Bilbao, University of the Basque Country (UPV/EHU), Alda. Urquijo s/n, 48013 Bilbao, Spain","institution_ids":["https://openalex.org/I169108374"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066307845","display_name":"Aitor Erkoreka","orcid":"https://orcid.org/0000-0001-5158-0170","observed_orcids":["https://orcid.org/0000-0001-5158-0170"]},"institutions":[{"id":"https://openalex.org/I169108374","display_name":"University of the Basque Country","ror":"https://ror.org/000xsnr85","country_code":"ES","type":"education","lineage":["https://openalex.org/I169108374"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"A. Erkoreka","raw_affiliation_strings":["Department of Thermal Engineering, Faculty of Engineering of Bilbao, University of the Basque Country (UPV/EHU), Alda. Urquijo s/n, 48013 Bilbao, Spain"],"raw_orcid":"https://orcid.org/0000-0001-5158-0170","affiliations":[{"raw_affiliation_string":"Department of Thermal Engineering, Faculty of Engineering of Bilbao, University of the Basque Country (UPV/EHU), Alda. Urquijo s/n, 48013 Bilbao, Spain","institution_ids":["https://openalex.org/I169108374"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043182032","display_name":"V\u00edctor de la Pe\u00f1a","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I169108374","display_name":"University of the Basque Country","ror":"https://ror.org/000xsnr85","country_code":"ES","type":"education","lineage":["https://openalex.org/I169108374"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"V. De la Pe\u00f1a","raw_affiliation_strings":["Department of Thermal Engineering, Faculty of Engineering of Bilbao, University of the Basque Country (UPV/EHU), Alda. Urquijo s/n, 48013 Bilbao, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Thermal Engineering, Faculty of Engineering of Bilbao, University of the Basque Country (UPV/EHU), Alda. Urquijo s/n, 48013 Bilbao, Spain","institution_ids":["https://openalex.org/I169108374"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5085339925","display_name":"Borja Herrazti","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2800916530","display_name":"Sener (Spain)","ror":"https://ror.org/03rjwv512","country_code":"ES","type":"company","lineage":["https://openalex.org/I2800916530"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"B. Herrazti","raw_affiliation_strings":["Department of Mechanical Engineering, SENER Ingenier\u00eda y Sistemas S.A., Avda. Zugazarte 56, 48930 Getxo, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, SENER Ingenier\u00eda y Sistemas S.A., Avda. Zugazarte 56, 48930 Getxo, Spain","institution_ids":["https://openalex.org/I2800916530"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5072319394"],"corresponding_institution_ids":["https://openalex.org/I169108374","https://openalex.org/I2800916530"],"apc_list":{"value":4600,"currency":"USD","value_usd":4600},"apc_paid":null,"fwci":6.2011,"has_fulltext":false,"cited_by_count":62,"citation_normalized_percentile":{"value":0.97353446,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":100},"biblio":{"volume":"182","issue":null,"first_page":"430","last_page":"450"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10568","display_name":"Thermodynamic and Exergetic Analyses of Power and Cooling Systems","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10568","display_name":"Thermodynamic and Exergetic Analyses of Power and Cooling Systems","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12139","display_name":"Advanced Thermodynamic Systems and Engines","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13856","display_name":"Advanced Power Generation Technologies","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/supercritical-co2-power-cycle","display_name":"supercritical CO2 cycle","score":0.9210000038146973},{"id":"https://openalex.org/keywords/concentrated-solar-power","display_name":"concentrated solar power","score":0.9929999709129333},{"id":"https://openalex.org/keywords/exergy-analysis","display_name":"exergy analysis","score":0.7070000171661377},{"id":"https://openalex.org/keywords/energy-efficiency","display_name":"energy efficiency","score":0.8510000109672546},{"id":"https://openalex.org/keywords/sensitivity-analysis","display_name":"sensitivity analysis","score":0.828000009059906},{"id":"https://openalex.org/keywords/recompression-cycle","display_name":"recompression cycle","score":0.9879999756813049},{"id":"https://openalex.org/keywords/recuperator-effectiveness","display_name":"recuperator effectiveness","score":0.7429999709129333},{"id":"https://openalex.org/keywords/irreversibility","display_name":"irreversibility","score":0.8389999866485596},{"id":"https://openalex.org/keywords/molten-salt-receiver","display_name":"molten salt receiver","score":0.7170000076293945}],"concepts":[{"id":"https://openalex.org/C113146524","wikidata":"https://www.wikidata.org/wiki/Q663290","display_name":"Exergy","level":2,"score":0.7609732151031494},{"id":"https://openalex.org/C118419359","wikidata":"https://www.wikidata.org/wiki/Q682585","display_name":"Supercritical fluid","level":2,"score":0.7272782325744629},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.5883859395980835},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5754808187484741},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.5512276887893677},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.47798556089401245},{"id":"https://openalex.org/C2779473208","wikidata":"https://www.wikidata.org/wiki/Q285927","display_name":"Concentrated solar power","level":3,"score":0.44480568170547485},{"id":"https://openalex.org/C541104983","wikidata":"https://www.wikidata.org/wiki/Q40015","display_name":"Solar energy","level":2,"score":0.4276980459690094},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.33040347695350647},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.3300737738609314},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.2342590093612671},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22492527961730957},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.19211211800575256},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11456996202468872},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1016/j.enconman.2018.12.016","doi":"https://doi.org/10.1016/j.enconman.2018.12.016","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.enconman.2018.12.016","pdf_url":null,"source":{"id":"https://openalex.org/S105637730","display_name":"Energy Conversion and Management","issn_l":"0196-8904","issn":["0196-8904","1879-2227"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-200","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Conversion and Management","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":1.0,"id":"https://metadata.un.org/sdg/13","display_name":"Climate action"},{"score":0.5378999710083008,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"},{"score":0.5171999931335449,"id":"https://metadata.un.org/sdg/12","display_name":"Responsible consumption and production"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321919","display_name":"Euskal Herriko Unibertsitatea","ror":"https://ror.org/000xsnr85"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W248248647","https://openalex.org/W1163097982","https://openalex.org/W1997986440","https://openalex.org/W2020071325","https://openalex.org/W2037225323","https://openalex.org/W2045191608","https://openalex.org/W2045551889","https://openalex.org/W2072358564","https://openalex.org/W2154131474","https://openalex.org/W2220923069","https://openalex.org/W2236589635","https://openalex.org/W2294924067","https://openalex.org/W2556604717","https://openalex.org/W2570310804","https://openalex.org/W2754511598","https://openalex.org/W2759298779","https://openalex.org/W2789985112","https://openalex.org/W2794622199","https://openalex.org/W2804596594","https://openalex.org/W2805503300","https://openalex.org/W2809709208","https://openalex.org/W2886093527","https://openalex.org/W2891272025"],"related_works":["https://openalex.org/W2236589635","https://openalex.org/W7023720669","https://openalex.org/W4235945487","https://openalex.org/W2420362292","https://openalex.org/W3172719025","https://openalex.org/W7220487339","https://openalex.org/W3121847715","https://openalex.org/W3037477566","https://openalex.org/W2914296194"],"abstract_inverted_index":null,"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2906825899","counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":10},{"year":2023,"cited_by_count":6},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":11},{"year":2020,"cited_by_count":23},{"year":2019,"cited_by_count":4}],"updated_date":"2026-11-14T11:04:58.165337","created_date":"2019-01-11T00:00:00"}
