{"id":"https://openalex.org/W2905077461","doi":"https://doi.org/10.1097/mbp.0000000000000358","title":"Comparison between invasive and noninvasive blood pressure measurements in critically ill patients receiving inotropes","display_name":"Comparison between invasive and noninvasive blood pressure measurements in critically ill patients receiving inotropes","publication_year":2018,"publication_date":"2018-12-07","ids":{"openalex":"https://openalex.org/W2905077461","doi":"https://doi.org/10.1097/mbp.0000000000000358","mag":"2905077461","pmid":"https://pubmed.ncbi.nlm.nih.gov/30531494"},"language":"en","primary_location":{"id":"doi:10.1097/mbp.0000000000000358","doi":"https://doi.org/10.1097/mbp.0000000000000358","is_oa":false,"landing_page_url":"https://doi.org/10.1097/mbp.0000000000000358","pdf_url":null,"source":{"id":"https://openalex.org/S39823226","display_name":"Blood Pressure Monitoring","issn_l":"1359-5237","issn":["1359-5237","1473-5725"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-1","ki-jl-1","medline","norway-1","poland-40","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310315671","host_organization_name":"Lippincott Williams & Wilkins","host_organization_lineage":["https://openalex.org/P4310315671","https://openalex.org/P4310318547"],"host_organization_lineage_names":["Lippincott Williams & Wilkins","Wolters Kluwer"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Blood Pressure Monitoring","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5000782162","display_name":"Babandeep Kaur","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Babandeep Kaur","raw_affiliation_strings":["National Institute of Nursing Education"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute of Nursing Education","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108128345","display_name":"Sukhpal Kaur","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I45294948","display_name":"Post Graduate Institute of Medical Education and Research","ror":"https://ror.org/009nfym65","country_code":"IN","type":"education","lineage":["https://openalex.org/I45294948"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Sukhpal Kaur","raw_affiliation_strings":["National Institute of Nursing Education","e-mails: [email\u00a0protected], [email\u00a0protected]","fax: +91 172 274 4401","to Sukhpal Kaur, PhD, National Institute of Nursing Education, Postgraduate Institute of Medical Education and Research, Chandigarh 160012, India Tel: +91 988 853 6964"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute of Nursing Education","institution_ids":[]},{"raw_affiliation_string":"e-mails: [email\u00a0protected], [email\u00a0protected]","institution_ids":[]},{"raw_affiliation_string":"fax: +91 172 274 4401","institution_ids":[]},{"raw_affiliation_string":"to Sukhpal Kaur, PhD, National Institute of Nursing Education, Postgraduate Institute of Medical Education and Research, Chandigarh 160012, India Tel: +91 988 853 6964","institution_ids":["https://openalex.org/I45294948"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072954708","display_name":"Lakshmi Narayana Yaddanapudi","orcid":"https://orcid.org/0000-0002-9822-0217","observed_orcids":["https://orcid.org/0000-0002-9822-0217"]},"institutions":[{"id":"https://openalex.org/I45294948","display_name":"Post Graduate Institute of Medical Education and Research","ror":"https://ror.org/009nfym65","country_code":"IN","type":"education","lineage":["https://openalex.org/I45294948"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Lakshmi N. Yaddanapudi","raw_affiliation_strings":["Department of Anaesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Anaesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, India","institution_ids":["https://openalex.org/I45294948"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5104174140","display_name":"Neena Vir Singh","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Neena V. Singh","raw_affiliation_strings":["National Institute of Nursing Education"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute of Nursing Education","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5000782162","https://openalex.org/A5108128345"],"corresponding_institution_ids":["https://openalex.org/I45294948"],"apc_list":null,"apc_paid":null,"fwci":0.7739,"has_fulltext":false,"cited_by_count":23,"citation_normalized_percentile":{"value":0.73486951,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":93,"max":99},"biblio":{"volume":"24","issue":"1","first_page":"24","last_page":"29"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.0013000000035390258,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10144","display_name":"Blood Pressure and Hypertension Studies","score":0.0008999999845400453,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/invasive-blood-pressure-monitoring","display_name":"invasive blood pressure monitoring","score":0.8529999852180481},{"id":"https://openalex.org/keywords/non-invasive-blood-pressure-measurement","display_name":"non-invasive blood pressure measurement","score":0.8989999890327454},{"id":"https://openalex.org/keywords/oscillometric-blood-pressure-monitor","display_name":"oscillometric blood pressure monitor","score":0.8230000138282776},{"id":"https://openalex.org/keywords/inotropic-agents","display_name":"inotropic agents","score":0.9129999876022339},{"id":"https://openalex.org/keywords/critically-ill-patients","display_name":"critically ill patients","score":0.8790000081062317},{"id":"https://openalex.org/keywords/arterial-cannula","display_name":"arterial cannula","score":0.7009999752044678},{"id":"https://openalex.org/keywords/method-agreement","display_name":"measurement agreement","score":0.6110000014305115},{"id":"https://openalex.org/keywords/systolic-and-diastolic-blood-pressure","display_name":"systolic and diastolic blood pressure","score":0.8270000219345093},{"id":"https://openalex.org/keywords/hemodynamic-monitoring","display_name":"hemodynamic monitoring","score":0.6650000214576721}],"concepts":[{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.8524640798568726},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.7202164530754089},{"id":"https://openalex.org/C57900726","wikidata":"https://www.wikidata.org/wiki/Q492905","display_name":"Diastole","level":3,"score":0.7159349322319031},{"id":"https://openalex.org/C155710745","wikidata":"https://www.wikidata.org/wiki/Q575278","display_name":"Inotrope","level":2,"score":0.6466341018676758},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.6200783252716064},{"id":"https://openalex.org/C2991859549","wikidata":"https://www.wikidata.org/wiki/Q679690","display_name":"Critically ill","level":2,"score":0.5236560702323914},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.5149012804031372},{"id":"https://openalex.org/C2778074680","wikidata":"https://www.wikidata.org/wiki/Q2125439","display_name":"Cannula","level":2,"score":0.4876364767551422},{"id":"https://openalex.org/C105054674","wikidata":"https://www.wikidata.org/wiki/Q3707381","display_name":"Mean difference","level":3,"score":0.45847609639167786},{"id":"https://openalex.org/C169554166","wikidata":"https://www.wikidata.org/wiki/Q496359","display_name":"Systole","level":4,"score":0.41725385189056396},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.2026461958885193},{"id":"https://openalex.org/C44249647","wikidata":"https://www.wikidata.org/wiki/Q208498","display_name":"Confidence interval","level":2,"score":0.1081288754940033}],"mesh":[{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D005260","descriptor_name":"Female","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008875","descriptor_name":"Middle Aged","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015924","descriptor_name":"Blood Pressure Monitors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D016638","descriptor_name":"Critical Illness","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1097/mbp.0000000000000358","doi":"https://doi.org/10.1097/mbp.0000000000000358","is_oa":false,"landing_page_url":"https://doi.org/10.1097/mbp.0000000000000358","pdf_url":null,"source":{"id":"https://openalex.org/S39823226","display_name":"Blood Pressure Monitoring","issn_l":"1359-5237","issn":["1359-5237","1473-5725"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-1","ki-jl-1","medline","norway-1","poland-40","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310315671","host_organization_name":"Lippincott Williams & Wilkins","host_organization_lineage":["https://openalex.org/P4310315671","https://openalex.org/P4310318547"],"host_organization_lineage_names":["Lippincott Williams & Wilkins","Wolters Kluwer"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Blood Pressure Monitoring","raw_type":"journal-article"},{"id":"pmid:30531494","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/30531494","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Blood pressure monitoring","raw_type":"Clinical Trial"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3","score":0.9940000176429749}],"study_designs":[{"display_name":"Observational Study","id":"https://openalex.org/study-designs/observational-study"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W55336370","https://openalex.org/W1496525977","https://openalex.org/W1579077552","https://openalex.org/W1845734325","https://openalex.org/W1969276775","https://openalex.org/W1991652362","https://openalex.org/W1992122264","https://openalex.org/W1994066573","https://openalex.org/W2003899531","https://openalex.org/W2033950879","https://openalex.org/W2049348680","https://openalex.org/W2058216123","https://openalex.org/W2058624555","https://openalex.org/W2066276684","https://openalex.org/W2068256384","https://openalex.org/W2083960157","https://openalex.org/W2106525065","https://openalex.org/W2107728559","https://openalex.org/W2158096939","https://openalex.org/W2418694730"],"related_works":["https://openalex.org/W2162873840","https://openalex.org/W4411770460","https://openalex.org/W3008329167","https://openalex.org/W4390796604","https://openalex.org/W1988405807","https://openalex.org/W4393338426","https://openalex.org/W3204465583","https://openalex.org/W2182104949","https://openalex.org/W3029300194","https://openalex.org/W7214925196"],"abstract_inverted_index":{"OBJECTIVE:":[0],"The":[1,37,175,233],"aim":[2],"of":[3,13,32,100,111,118,123,128,137,152,161,165,173,182,184,188,202,240],"this":[4],"study":[5,25],"was":[6,26,39,93,105,177,207,245],"to":[7,77,225],"compare":[8],"invasive":[9,51,65,114,226],"and":[10,58,69,116,139,146,154,163,186,193],"noninvasive":[11,70],"monitoring":[12,54],"blood":[14],"pressure":[15,167],"(BP)":[16],"in":[17,29,180,229],"patients":[18,47,230],"on":[19],"inotropes.":[20,232],"SETTINGS":[21],"AND":[22,43],"DESIGN:":[23],"This":[24],"carried":[27,131],"out":[28],"the":[30,78,91,126,171,200,205,238,243],"ICU":[31],"a":[33,150,222],"tertiary":[34],"care":[35],"centre.":[36],"design":[38],"comparative":[40],"analytical.":[41],"PATIENTS":[42],"METHODS:":[44],"Thirty-six":[45],"adult":[46],"receiving":[48,231],"inotropes":[49,129,203,241],"with":[50,113,120,125,199,237],"arterial":[52,67],"BP":[53,115,141,195,211],"were":[55,61,130,143,169,197],"studied.":[56],"Systolic":[57,145],"diastolic":[59,140,147,166,189,194],"BPs":[60],"recorded":[62],"simultaneously":[63],"using":[64,95,213],"(radial":[66],"cannula)":[68],"(Philips":[71,217],"Intellivue":[72,218],"MP-60":[73],"oscillometric":[74],"monitor":[75,216],"attached":[76],"opposite":[79],"arm)":[80],"methods":[81,92],"every":[82],"30":[83],"min.":[84],"STATISTICAL":[85],"ANALYSIS:":[86],"Agreement":[87],"(precision)":[88],"between":[89],"both":[90],"assessed":[94],"Bland-Altman":[96],"analysis.":[97],"A":[98],"difference":[99,112,124,151,176,235],"more":[101],"than":[102],"10":[103],"mmHg":[104],"considered":[106],"clinically":[107,178],"unacceptable.":[108],"Linear":[109],"regression":[110],"analysis":[117],"variance":[119],"Tukey's":[121],"correction":[122],"number":[127,201,239],"out.":[132],"RESULTS:":[133],"Overall,":[134],"1400":[135],"pairs":[136],"systolic":[138,162,185,192],"measurements":[142,168,183],"obtained.":[144],"pressures":[148],"showed":[149],"2.3\u00b116.9":[153],"0.7\u00b110.6":[155],"mmHg,":[156],"respectively.":[157],"In":[158],"all,":[159],"93.4%":[160],"98.6%":[164],"within":[170],"limits":[172],"agreement.":[174],"acceptable":[179],"54.2%":[181],"74.1%":[187],"measurements.":[190],"Both":[191],"differences":[196],"correlated":[198],"that":[204,242],"patient":[206,244],"receiving.":[208,246],"CONCLUSION:":[209],"Noninvasive":[210],"measurement":[212,228],"an":[214],"oscilllometric":[215],"MP-60)":[219],"is":[220],"not":[221],"reliable":[223],"alternative":[224],"intra-arterial":[227],"observed":[234],"increased":[236]},"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":8},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":3}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2018-12-22T00:00:00"}
