{"id":"https://openalex.org/W2888040468","doi":"https://doi.org/10.1109/icees.2018.8442395","title":"Performance Analysis of Reduced Switch Boost Multilevel Hybrid Converter","display_name":"Performance Analysis of Reduced Switch Boost Multilevel Hybrid Converter","publication_year":2018,"publication_date":"2018-02-01","ids":{"openalex":"https://openalex.org/W2888040468","doi":"https://doi.org/10.1109/icees.2018.8442395","mag":"2888040468"},"language":"en","primary_location":{"id":"doi:10.1109/icees.2018.8442395","doi":"https://doi.org/10.1109/icees.2018.8442395","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icees.2018.8442395","pdf_url":null,"source":{"id":"https://openalex.org/S7407086565","display_name":"International Conference on Electrical Energy Systems (ICEES)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 4th International Conference on Electrical Energy Systems (ICEES)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111169021","display_name":"S. Jeyasudha","orcid":"https://orcid.org/0000-0001-8850-063X","observed_orcids":["https://orcid.org/0000-0001-8850-063X"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"S. Jeyasudha","raw_affiliation_strings":["Department of EEE PEC, Puducherry, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of EEE PEC, Puducherry, India","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5008954805","display_name":"B. Geethalakshmi","orcid":"https://orcid.org/0000-0002-5809-2759","observed_orcids":["https://orcid.org/0000-0002-5809-2759"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"B. Geethalakshmi","raw_affiliation_strings":["Department of EEE PEC, Puducherry, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of EEE PEC, Puducherry, India","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.3996,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.41559293,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"14","last_page":"19"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/multilevel-inverter","display_name":"multilevel inverter","score":0.925000011920929},{"id":"https://openalex.org/keywords/cascaded-multilevel-inverter","display_name":"cascaded multilevel inverter","score":0.8349999785423279},{"id":"https://openalex.org/keywords/photovoltaic-systems","display_name":"photovoltaic systems","score":0.7839999794960022},{"id":"https://openalex.org/keywords/power-converter-topology","display_name":"converter topology","score":0.6320000290870667},{"id":"https://openalex.org/keywords/converter-losses","display_name":"converter losses","score":0.6740000247955322},{"id":"https://openalex.org/keywords/converter-cost-reduction","display_name":"converter cost reduction","score":0.7049999833106995}],"concepts":[{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.7053202390670776},{"id":"https://openalex.org/C111335779","wikidata":"https://www.wikidata.org/wiki/Q3454686","display_name":"Reduction (mathematics)","level":2,"score":0.6873248815536499},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.6687788963317871},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6054612398147583},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.515063464641571},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4840254485607147},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3107924461364746},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.29150116443634033},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.12765038013458252},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icees.2018.8442395","doi":"https://doi.org/10.1109/icees.2018.8442395","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icees.2018.8442395","pdf_url":null,"source":{"id":"https://openalex.org/S7407086565","display_name":"International Conference on Electrical Energy Systems (ICEES)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 4th International Conference on Electrical Energy Systems (ICEES)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9853000044822693,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1597316751","https://openalex.org/W1964193767","https://openalex.org/W1967458057","https://openalex.org/W1978144444","https://openalex.org/W2050869149","https://openalex.org/W2074667607","https://openalex.org/W2075567203","https://openalex.org/W2105335831","https://openalex.org/W2126745577","https://openalex.org/W2153340111","https://openalex.org/W2754946676","https://openalex.org/W3191169494","https://openalex.org/W4214617712"],"related_works":["https://openalex.org/W2754946676","https://openalex.org/W2768374306","https://openalex.org/W2911943075","https://openalex.org/W2962569382","https://openalex.org/W4212866665","https://openalex.org/W2557382556","https://openalex.org/W4391807833","https://openalex.org/W2990021161","https://openalex.org/W3137043458","https://openalex.org/W4400475018"],"abstract_inverted_index":{"This":[0,33],"work":[1],"proposes":[2],"a":[3,28,39],"novel":[4],"topology":[5,35,52,76],"of":[6,43,50,63,84,88,93,103],"reduced":[7],"switch":[8],"boost":[9],"multilevel":[10,20,71],"hybrid":[11],"converter":[12],"(RSBMHC)":[13],"which":[14],"has":[15],"the":[16,51,60,64,69,78,97,104,108],"capability":[17],"to":[18],"obtain":[19],"AC":[21],"output":[22,25],"and":[23,59,99],"DC":[24,29],"voltages":[26],"from":[27],"input":[30],"voltage":[31],"concurrently.":[32],"RSBMHC":[34,65],"is":[36,53,66],"developed":[37],"for":[38],"smart":[40],"residential":[41],"application":[42],"solar":[44],"PV":[45],"system":[46],"(SPV).":[47],"The":[48,74],"simulation":[49],"worked":[54],"out":[55],"by":[56],"using":[57],"MATLAB/Simulink,":[58],"investigated":[61],"performance":[62],"compared":[67],"with":[68],"basic":[70,89],"inverter":[72],"(MLI).":[73],"proposed":[75],"gives":[77],"results":[79],"of,":[80],"reduction":[81,92,100,106],"in":[82,96,101,107],"number":[83],"semiconductor":[85],"component":[86],"count":[87],"cascaded":[90],"MLI,":[91],"losses":[94],"created":[95],"circuit,":[98],"cost":[102],"converter,":[105],"installation":[109],"area.":[110]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2020,"cited_by_count":1}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2018-08-31T00:00:00"}
