{"id":"https://openalex.org/W2810799176","doi":"https://doi.org/10.1109/sbse.2018.8395703","title":"Analysis of the distribution network reconfiguration using the OpenDSS\u00ae software","display_name":"Analysis of the distribution network reconfiguration using the OpenDSS\u00ae software","alternate_titles":[],"publication_year":2018,"publication_date":"2018-05-01","ids":{"openalex":"https://openalex.org/W2810799176","doi":"https://doi.org/10.1109/sbse.2018.8395703","mag":"2810799176"},"language":"en","primary_location":{"id":"doi:10.1109/sbse.2018.8395703","doi":"https://doi.org/10.1109/sbse.2018.8395703","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sbse.2018.8395703","pdf_url":null,"source":{"id":"https://openalex.org/S4306498386","display_name":"2018 Simposio Brasileiro de Sistemas Eletricos (SBSE)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 Simposio Brasileiro de Sistemas Eletricos (SBSE)","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2810799176"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5025828973","display_name":"Roberta Carvalho Marques","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I72872986","display_name":"Universidade Federal do Pampa","ror":"https://ror.org/003qt4p19","country_code":"BR","type":"education","lineage":["https://openalex.org/I72872986"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Roberta C. Marques","raw_affiliation_strings":["Group of Energy and Electric Power Systems - GESEP Federal University of Pampa - UNIPAMPA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Group of Energy and Electric Power Systems - GESEP Federal University of Pampa - UNIPAMPA","institution_ids":["https://openalex.org/I72872986"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050730212","display_name":"Henrique S. Eichkoff","orcid":"https://orcid.org/0000-0001-9497-4540","observed_orcids":["https://orcid.org/0000-0001-9497-4540"]},"institutions":[{"id":"https://openalex.org/I72872986","display_name":"Universidade Federal do Pampa","ror":"https://ror.org/003qt4p19","country_code":"BR","type":"education","lineage":["https://openalex.org/I72872986"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Henrique S. Eichkoff","raw_affiliation_strings":["Group of Energy and Electric Power Systems - GESEP Federal University of Pampa - UNIPAMPA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Group of Energy and Electric Power Systems - GESEP Federal University of Pampa - UNIPAMPA","institution_ids":["https://openalex.org/I72872986"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5110728541","display_name":"Ana Paula Carboni de Mello","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I72872986","display_name":"Universidade Federal do Pampa","ror":"https://ror.org/003qt4p19","country_code":"BR","type":"education","lineage":["https://openalex.org/I72872986"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Ana Paula C. de Mello","raw_affiliation_strings":["Group of Energy and Electric Power Systems - GESEP Federal University of Pampa - UNIPAMPA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Group of Energy and Electric Power Systems - GESEP Federal University of Pampa - UNIPAMPA","institution_ids":["https://openalex.org/I72872986"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I72872986"],"apc_list":null,"apc_paid":null,"fwci":1.1082,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.69618299,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10424","display_name":"Electric Power System Optimization","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/distribution-network-reconfiguration","display_name":"distribution network reconfiguration","score":0.9990000128746033},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"distributed generation","score":0.8040000200271606},{"id":"https://openalex.org/keywords/photovoltaic-generation","display_name":"photovoltaic generation","score":0.9919999837875366},{"id":"https://openalex.org/keywords/opendss","display_name":"OpenDSS","score":0.828000009059906},{"id":"https://openalex.org/keywords/ieee-123-bus-test-system","display_name":"IEEE 123-bus test system","score":0.8159999847412109},{"id":"https://openalex.org/keywords/distribution-network-topology","display_name":"distribution network topology","score":0.7570000290870667},{"id":"https://openalex.org/keywords/distribution-networks","display_name":"distribution networks","score":0.5130000114440918}],"concepts":[{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.8081710338592529},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7120683193206787},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.5999496579170227},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.5724079012870789},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.5698440074920654},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.5597554445266724},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.5289768576622009},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.4565753936767578},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.43358585238456726},{"id":"https://openalex.org/C113843644","wikidata":"https://www.wikidata.org/wiki/Q901882","display_name":"Interface (matter)","level":4,"score":0.4329186975955963},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.33726346492767334},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.269369900226593},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.18497002124786377},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.17624294757843018},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12904664874076843},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.0684027373790741},{"id":"https://openalex.org/C129307140","wikidata":"https://www.wikidata.org/wiki/Q6795880","display_name":"Maximum bubble pressure method","level":3,"score":0.0},{"id":"https://openalex.org/C157915830","wikidata":"https://www.wikidata.org/wiki/Q2928001","display_name":"Bubble","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/sbse.2018.8395703","doi":"https://doi.org/10.1109/sbse.2018.8395703","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sbse.2018.8395703","pdf_url":null,"source":{"id":"https://openalex.org/S4306498386","display_name":"2018 Simposio Brasileiro de Sistemas Eletricos (SBSE)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 Simposio Brasileiro de Sistemas Eletricos (SBSE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"},{"score":0.9853000044822693,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":2,"referenced_works":["https://openalex.org/W2064119603","https://openalex.org/W2117750133"],"related_works":["https://openalex.org/W2771545168","https://openalex.org/W2888682681","https://openalex.org/W4231964617","https://openalex.org/W2007410752","https://openalex.org/W4388806845","https://openalex.org/W4401019294","https://openalex.org/W2998656480","https://openalex.org/W2125915645","https://openalex.org/W2070171588","https://openalex.org/W2903427463"],"abstract_inverted_index":{"This":[0],"paper":[1],"proposes":[2],"the":[3,6,14,19,28,47,56,76],"analysis":[4,40],"of":[5,65],"distribution":[7,44,60],"networks":[8],"reconfiguration":[9],"with":[10,62],"distributed":[11,63],"generators":[12,64],"using":[13],"Branch":[15],"Exchange":[16],"method":[17],"through":[18,75],"OpenDSS\u00ae":[20],"/MATLAB\u00ae":[21],"interface.":[22],"The":[23,38,71],"proposal":[24],"is":[25],"to":[26],"define":[27],"best":[29],"topology":[30],"for":[31],"network":[32,45,61],"operation":[33],"in":[34,46],"two":[35],"different":[36],"situations.":[37],"first":[39],"considers":[41],"a":[42,59],"conventional":[43],"normal":[48],"operating":[49],"state":[50],"without":[51],"additional":[52],"generation":[53,67],"sources.":[54],"In":[55],"second":[57],"one,":[58],"photovoltaic":[66],"technology":[68],"was":[69],"considered.":[70],"studies":[72],"were":[73],"obtained":[74],"IEEE":[77],"123":[78],"bus":[79],"standard":[80],"test":[81],"system.":[82]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2810799176","counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2018-07-10T00:00:00"}
