{"id":"https://openalex.org/W2810694210","doi":"https://doi.org/10.1109/epe.2018.8395956","title":"Reactive power compensation of wind permanent magnet synchronous generator - part II","display_name":"Reactive power compensation of wind permanent magnet synchronous generator - part II","publication_year":2018,"publication_date":"2018-05-01","ids":{"openalex":"https://openalex.org/W2810694210","doi":"https://doi.org/10.1109/epe.2018.8395956","mag":"2810694210"},"language":"en","primary_location":{"id":"doi:10.1109/epe.2018.8395956","doi":"https://doi.org/10.1109/epe.2018.8395956","is_oa":false,"landing_page_url":"https://doi.org/10.1109/epe.2018.8395956","pdf_url":null,"source":{"id":"https://openalex.org/S4306420053","display_name":"International Scientific Conference on Electric Power Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 19th International Scientific Conference on Electric Power Engineering (EPE)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5003050726","display_name":"Nikolay F. Djagarov","orcid":"https://orcid.org/0000-0002-4234-4659","observed_orcids":["https://orcid.org/0000-0002-4234-4659"]},"institutions":[{"id":"https://openalex.org/I4210146773","display_name":"Nikola Vaptsarov Naval Academy","ror":"https://ror.org/04rszy995","country_code":"BG","type":"education","lineage":["https://openalex.org/I4210146773"]}],"countries":["BG"],"is_corresponding":false,"raw_author_name":"Nikolay Djagarov","raw_affiliation_strings":["Electrical Department, Nikola Vaptsarov Naval Academy, Varna, Bulgaria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Department, Nikola Vaptsarov Naval Academy, Varna, Bulgaria","institution_ids":["https://openalex.org/I4210146773"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5016800942","display_name":"Zhivko Grozdev","orcid":"https://orcid.org/0000-0003-1143-8799","observed_orcids":["https://orcid.org/0000-0003-1143-8799"]},"institutions":[{"id":"https://openalex.org/I4210146773","display_name":"Nikola Vaptsarov Naval Academy","ror":"https://ror.org/04rszy995","country_code":"BG","type":"education","lineage":["https://openalex.org/I4210146773"]}],"countries":["BG"],"is_corresponding":false,"raw_author_name":"Zhivko Grozdev","raw_affiliation_strings":["Electrical Department, Nikola Vaptsarov Naval Academy, Varna, Bulgaria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Department, Nikola Vaptsarov Naval Academy, Varna, Bulgaria","institution_ids":["https://openalex.org/I4210146773"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040382192","display_name":"Julia Djagarova","orcid":"https://orcid.org/0000-0003-3593-6792","observed_orcids":["https://orcid.org/0000-0003-3593-6792"]},"institutions":[{"id":"https://openalex.org/I147527907","display_name":"Technical University of Varna","ror":"https://ror.org/03zrwm897","country_code":"BG","type":"education","lineage":["https://openalex.org/I147527907"]}],"countries":["BG"],"is_corresponding":false,"raw_author_name":"Julia Djagarova","raw_affiliation_strings":["Technical University, Varna, Bulgaria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Technical University, Varna, Bulgaria","institution_ids":["https://openalex.org/I147527907"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5076370166","display_name":"Hristo Milushev","orcid":"https://orcid.org/0000-0002-8018-0106","observed_orcids":["https://orcid.org/0000-0002-8018-0106"]},"institutions":[{"id":"https://openalex.org/I4210146773","display_name":"Nikola Vaptsarov Naval Academy","ror":"https://ror.org/04rszy995","country_code":"BG","type":"education","lineage":["https://openalex.org/I4210146773"]}],"countries":["BG"],"is_corresponding":false,"raw_author_name":"Hristo Milushev","raw_affiliation_strings":["Electrical Department, Nikola Vaptsarov Naval Academy, Varna, Bulgaria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Department, Nikola Vaptsarov Naval Academy, Varna, Bulgaria","institution_ids":["https://openalex.org/I4210146773"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5015861799","display_name":"Sergey E. Kokin","orcid":"https://orcid.org/0000-0001-7493-172X","observed_orcids":["https://orcid.org/0000-0001-7493-172X"]},"institutions":[{"id":"https://openalex.org/I130823665","display_name":"Ural Federal University","ror":"https://ror.org/00hs7dr46","country_code":"RU","type":"education","lineage":["https://openalex.org/I130823665"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"Sergey Kokin","raw_affiliation_strings":["Ural Energy Institute, Ural Federal University, Yekaterinburg, Russia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Ural Energy Institute, Ural Federal University, Yekaterinburg, Russia","institution_ids":["https://openalex.org/I130823665"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.1989,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.71535612,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":95},"biblio":{"volume":"3","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.8682000041007996,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.8682000041007996,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.09600000083446503,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.011900000274181366,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reactive-power-compensation","display_name":"reactive power compensation","score":0.9959999918937683},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"permanent magnet synchronous generator","score":0.8339999914169312},{"id":"https://openalex.org/keywords/wind-turbine-generator","display_name":"wind turbine generator","score":0.6790000200271606},{"id":"https://openalex.org/keywords/static-var-compensator","display_name":"static VAR compensator","score":0.9369999766349792},{"id":"https://openalex.org/keywords/voltage-sag","display_name":"voltage sag","score":0.5170000195503235},{"id":"https://openalex.org/keywords/power-quality","display_name":"power quality","score":0.4399999976158142},{"id":"https://openalex.org/keywords/generator-control","display_name":"generator control","score":0.3790000081062317}],"concepts":[{"id":"https://openalex.org/C201320609","wikidata":"https://www.wikidata.org/wiki/Q3274420","display_name":"Permanent magnet synchronous generator","level":3,"score":0.8557536602020264},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.6436288356781006},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.6398577690124512},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6188814043998718},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6110193729400635},{"id":"https://openalex.org/C82178898","wikidata":"https://www.wikidata.org/wiki/Q166839","display_name":"Voltage drop","level":3,"score":0.6006791591644287},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5417214035987854},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.5365861058235168},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.5361940860748291},{"id":"https://openalex.org/C2986715156","wikidata":"https://www.wikidata.org/wiki/Q49833","display_name":"Wind generator","level":3,"score":0.5219278335571289},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.48144930601119995},{"id":"https://openalex.org/C98716924","wikidata":"https://www.wikidata.org/wiki/Q752750","display_name":"Induction generator","level":3,"score":0.4339814782142639},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.42347362637519836},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.35443875193595886},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3468186557292938},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3236526846885681},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3209790587425232},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.17343664169311523},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.10702663660049438},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/epe.2018.8395956","doi":"https://doi.org/10.1109/epe.2018.8395956","is_oa":false,"landing_page_url":"https://doi.org/10.1109/epe.2018.8395956","pdf_url":null,"source":{"id":"https://openalex.org/S4306420053","display_name":"International Scientific Conference on Electric Power Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 19th International Scientific Conference on Electric Power Engineering (EPE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8485000133514404,"id":"https://metadata.un.org/sdg/7"},{"display_name":"Industry, innovation and infrastructure","score":0.4943999946117401,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"},{"id":"https://openalex.org/F4320337624","display_name":"U.S. Naval Academy","ror":"https://ror.org/00znex860"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W793188610","https://openalex.org/W1992144040","https://openalex.org/W1994351988","https://openalex.org/W1999312996","https://openalex.org/W2001716020","https://openalex.org/W2014624139","https://openalex.org/W2017767552","https://openalex.org/W2023426854","https://openalex.org/W2055083199","https://openalex.org/W2078871156","https://openalex.org/W2100959566","https://openalex.org/W2130596545","https://openalex.org/W2139659941","https://openalex.org/W2167844025","https://openalex.org/W2223295923","https://openalex.org/W2269166164","https://openalex.org/W2479450933","https://openalex.org/W2512570802","https://openalex.org/W2547923478","https://openalex.org/W2588900156","https://openalex.org/W6689131924"],"related_works":["https://openalex.org/W4234072162","https://openalex.org/W2964919847","https://openalex.org/W1552023286","https://openalex.org/W2534659654","https://openalex.org/W2474006326","https://openalex.org/W2389289703","https://openalex.org/W1896042513","https://openalex.org/W2522930526","https://openalex.org/W7203550746","https://openalex.org/W2900425458"],"abstract_inverted_index":{"It":[0],"is":[1],"suggested":[2],"the":[3,30,38,46,49,56],"use":[4],"of":[5,12,48,52],"a":[6],"static":[7],"var":[8],"compensator":[9],"for":[10,16],"providing":[11],"low":[13],"voltage":[14],"through":[15],"wind":[17],"permanent":[18],"magnet":[19],"synchronous":[20],"generator.":[21],"Voltage":[22],"drop":[23],"and":[24,37,55],"symmetrical":[25],"short":[26],"circuit":[27],"modes":[28],"in":[29],"network":[31],"were":[32],"investigated":[33],"using":[34],"mathematical":[35],"model":[36],"proposed":[39,50],"control":[40,51],"[1].":[41],"The":[42],"simulation":[43],"results":[44],"show":[45],"effectiveness":[47],"these":[53],"disturbances":[54],"ability":[57],"to":[58],"ensure":[59],"sustainable":[60],"work.":[61]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":2}],"updated_date":"2026-10-06T10:28:23.643775","created_date":"2018-07-10T00:00:00"}
