{"id":"https://openalex.org/W2809033124","doi":"https://doi.org/10.2172/1365710","title":"Chapter 18: Variable Frequency Drive Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures","display_name":"Chapter 18: Variable Frequency Drive Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures","alternate_titles":[],"publication_year":2017,"publication_date":"2017-06-21","ids":{"openalex":"https://openalex.org/W2809033124","doi":"https://doi.org/10.2172/1365710","mag":"2809033124"},"language":"en","primary_location":{"id":"doi:10.2172/1365710","doi":"https://doi.org/10.2172/1365710","is_oa":true,"landing_page_url":"https://doi.org/10.2172/1365710","pdf_url":"https://www.osti.gov/servlets/purl/1365710","source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"National Renewable Energy Laboratory (NREL)","raw_type":"report"},"parent_works":[],"lineage":["https://openalex.org/W2809033124"],"child_works_count":0,"pull_notice_works":[],"type":"report","is_traditional":false,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://www.osti.gov/servlets/purl/1365710","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5076491613","display_name":"Jeff Romberger","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Jeff Romberger","raw_affiliation_strings":["SBW Consulting, Inc., Bellevue, WA (United States)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"SBW Consulting, Inc., Bellevue, WA (United States)","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5076491613"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":true,"cited_by_count":3,"reviewed_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11954","display_name":"Energy Efficiency and Management","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11954","display_name":"Energy Efficiency and Management","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13093","display_name":"Electric Power Systems and Control","score":0.0035000001080334187,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.0027000000700354576,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/variable-frequency-drive","display_name":"variable frequency drive","score":0.9980000257492065},{"id":"https://openalex.org/keywords/energy-efficiency-savings","display_name":"energy efficiency savings","score":0.734000027179718},{"id":"https://openalex.org/keywords/energy-efficient-technologies","display_name":"energy-saving technologies","score":0.578000009059906},{"id":"https://openalex.org/keywords/centrifugal-fan","display_name":"centrifugal fan","score":0.7570000290870667},{"id":"https://openalex.org/keywords/pumps","display_name":"pumps","score":0.902999997138977},{"id":"https://openalex.org/keywords/motor-speed-control","display_name":"motor speed control","score":0.847000002861023},{"id":"https://openalex.org/keywords/industrial-energy-efficiency","display_name":"industrial energy efficiency","score":0.5600000023841858}],"concepts":[{"id":"https://openalex.org/C144171764","wikidata":"https://www.wikidata.org/wiki/Q48103","display_name":"Torque","level":2,"score":0.633235514163971},{"id":"https://openalex.org/C182365436","wikidata":"https://www.wikidata.org/wiki/Q50701","display_name":"Variable (mathematics)","level":2,"score":0.595626950263977},{"id":"https://openalex.org/C2777027219","wikidata":"https://www.wikidata.org/wiki/Q1284190","display_name":"Constant (computer programming)","level":2,"score":0.515849769115448},{"id":"https://openalex.org/C2780385302","wikidata":"https://www.wikidata.org/wiki/Q367158","display_name":"Protocol (science)","level":3,"score":0.5100027322769165},{"id":"https://openalex.org/C107551265","wikidata":"https://www.wikidata.org/wiki/Q1458245","display_name":"Displacement (psychology)","level":2,"score":0.4407442808151245},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.44046032428741455},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4336146414279938},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4041725695133209},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3833898901939392},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.10294240713119507},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.08566266298294067},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07537874579429626},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C204787440","wikidata":"https://www.wikidata.org/wiki/Q188504","display_name":"Alternative medicine","level":2,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C542102704","wikidata":"https://www.wikidata.org/wiki/Q183257","display_name":"Psychotherapist","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.2172/1365710","doi":"https://doi.org/10.2172/1365710","is_oa":true,"landing_page_url":"https://doi.org/10.2172/1365710","pdf_url":"https://www.osti.gov/servlets/purl/1365710","source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"National Renewable Energy Laboratory (NREL)","raw_type":"report"},{"id":"pmh:oai:osti.gov:1365710","doi":null,"is_oa":true,"landing_page_url":"https://www.osti.gov/biblio/1365710","pdf_url":"https://www.osti.gov/servlets/purl/1365710","source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":{"id":"doi:10.2172/1365710","doi":"https://doi.org/10.2172/1365710","is_oa":true,"landing_page_url":"https://doi.org/10.2172/1365710","pdf_url":"https://www.osti.gov/servlets/purl/1365710","source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"National Renewable Energy Laboratory (NREL)","raw_type":"report"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320306084","display_name":"U.S. Department of Energy","ror":"https://ror.org/01bj3aw27"},{"id":"https://openalex.org/F4320338290","display_name":"National Laboratory of the Rockies","ror":"https://ror.org/036266993"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2809033124.pdf","grobid_xml":"https://content.openalex.org/works/W2809033124.grobid-xml"},"referenced_works_count":2,"referenced_works":["https://openalex.org/W2290543578","https://openalex.org/W4235979656"],"related_works":["https://openalex.org/W2302416115","https://openalex.org/W2514791102","https://openalex.org/W4244983144","https://openalex.org/W7097818479","https://openalex.org/W2153376104","https://openalex.org/W2089680020","https://openalex.org/W590075822","https://openalex.org/W3014289359","https://openalex.org/W4389529043","https://openalex.org/W3133922818"],"abstract_inverted_index":{"An":[0],"adjustable-speed":[1],"drive":[2],"(ASD)":[3],"includes":[4],"all":[5],"devices":[6,24],"that":[7,17,25],"vary":[8,18],"the":[9,19,32],"speed":[10,21,29],"of":[11],"a":[12],"rotating":[13],"load,":[14],"including":[15],"those":[16,72],"motor":[20,28],"and":[22,53,58],"linkage":[23],"allow":[26],"constant":[27],"while":[30],"varying":[31],"load":[33,68],"speed.":[34,65],"The":[35],"Variable":[36],"Frequency":[37],"Drive":[38],"Evaluation":[39],"Protocol":[40],"presented":[41],"here":[42],"addresses":[43],"evaluation":[44],"issues":[45],"for":[46,60,73],"variable-frequency":[47],"drives":[48],"(VFDs)":[49],"installed":[50],"on":[51],"commercial":[52],"industrial":[54],"motor-driven":[55],"centrifugal":[56],"fans":[57],"pumps":[59],"which":[61],"torque":[62,67],"varies":[63],"with":[64],"Constant":[66],"applications,":[69],"such":[70],"as":[71],"positive":[74],"displacement":[75],"pumps,":[76],"are":[77],"not":[78],"covered":[79],"by":[80],"this":[81],"protocol.":[82]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2809033124","counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-11-24T14:10:38.155754","created_date":"2018-06-29T00:00:00"}
