{"id":"https://openalex.org/W2807477463","doi":"https://doi.org/10.1016/j.enbuild.2018.05.051","title":"Investigating the potential of a closed-loop dynamic insulation system for opaque building elements","display_name":"Investigating the potential of a closed-loop dynamic insulation system for opaque building elements","alternate_titles":[],"publication_year":2018,"publication_date":"2018-06-04","ids":{"openalex":"https://openalex.org/W2807477463","doi":"https://doi.org/10.1016/j.enbuild.2018.05.051","mag":"2807477463"},"language":"en","primary_location":{"id":"doi:10.1016/j.enbuild.2018.05.051","doi":"https://doi.org/10.1016/j.enbuild.2018.05.051","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.enbuild.2018.05.051","pdf_url":"https://www.sciencedirect.com/science/article/pii/S0378778818306601/pdf","source":{"id":"https://openalex.org/S6846437","display_name":"Energy and Buildings","issn_l":"0378-7788","issn":["0378-7788","1872-6178"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-3","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy and Buildings","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2807477463"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://www.sciencedirect.com/science/article/pii/S0378778818306601/pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5007100974","display_name":"Stefan Koenders","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I83019370","display_name":"Eindhoven University of Technology","ror":"https://ror.org/02c2kyt77","country_code":"NL","type":"education","lineage":["https://openalex.org/I83019370"]}],"countries":["NL"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"S.J.M. Koenders","raw_affiliation_strings":["Unit Building Physics and Services, Eindhoven University of Technology, the Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Unit Building Physics and Services, Eindhoven University of Technology, the Netherlands","institution_ids":["https://openalex.org/I83019370"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5016499098","display_name":"Roel Loonen","orcid":"https://orcid.org/0000-0001-6101-1449","observed_orcids":["https://orcid.org/0000-0001-6101-1449"]},"institutions":[{"id":"https://openalex.org/I83019370","display_name":"Eindhoven University of Technology","ror":"https://ror.org/02c2kyt77","country_code":"NL","type":"education","lineage":["https://openalex.org/I83019370"]}],"countries":["NL"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"R.C.G.M. Loonen","raw_affiliation_strings":["Unit Building Physics and Services, Eindhoven University of Technology, the Netherlands"],"raw_orcid":"https://orcid.org/0000-0001-6101-1449","affiliations":[{"raw_affiliation_string":"Unit Building Physics and Services, Eindhoven University of Technology, the Netherlands","institution_ids":["https://openalex.org/I83019370"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5058024612","display_name":"Jlm Jan Hensen","orcid":"https://orcid.org/0000-0002-7528-4234","observed_orcids":["https://orcid.org/0000-0002-7528-4234"]},"institutions":[{"id":"https://openalex.org/I83019370","display_name":"Eindhoven University of Technology","ror":"https://ror.org/02c2kyt77","country_code":"NL","type":"education","lineage":["https://openalex.org/I83019370"]}],"countries":["NL"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"J.L.M. Hensen","raw_affiliation_strings":["Unit Building Physics and Services, Eindhoven University of Technology, the Netherlands"],"raw_orcid":"https://orcid.org/0000-0002-7528-4234","affiliations":[{"raw_affiliation_string":"Unit Building Physics and Services, Eindhoven University of Technology, the Netherlands","institution_ids":["https://openalex.org/I83019370"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5016499098"],"corresponding_institution_ids":["https://openalex.org/I83019370"],"apc_list":{"value":4260,"currency":"USD","value_usd":4260},"apc_paid":{"value":4260,"currency":"USD","value_usd":4260},"fwci":5.3582,"has_fulltext":true,"cited_by_count":81,"citation_normalized_percentile":{"value":0.95175771,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":97,"max":99},"biblio":{"volume":"173","issue":null,"first_page":"409","last_page":"427"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9833999872207642,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9833999872207642,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13298","display_name":"Solar Energy Systems and Technologies","score":0.007400000002235174,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.007000000216066837,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/thermal-transmittance","display_name":"thermal transmittance","score":0.7329999804496765},{"id":"https://openalex.org/keywords/passive-cooling","display_name":"passive cooling","score":0.4519999921321869},{"id":"https://openalex.org/keywords/indoor-thermal-comfort","display_name":"indoor thermal comfort","score":0.7770000100135803},{"id":"https://openalex.org/keywords/building-energy-consumption","display_name":"building energy consumption","score":0.625},{"id":"https://openalex.org/keywords/facade-construction","display_name":"facade construction","score":0.8370000123977661}],"concepts":[{"id":"https://openalex.org/C159927051","wikidata":"https://www.wikidata.org/wiki/Q5318984","display_name":"Dynamic insulation","level":5,"score":0.837255597114563},{"id":"https://openalex.org/C2778284599","wikidata":"https://www.wikidata.org/wiki/Q25340000","display_name":"Overheating (electricity)","level":2,"score":0.7323346138000488},{"id":"https://openalex.org/C64839514","wikidata":"https://www.wikidata.org/wiki/Q918306","display_name":"Thermal insulation","level":3,"score":0.6060584187507629},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.5400048494338989},{"id":"https://openalex.org/C2776152135","wikidata":"https://www.wikidata.org/wiki/Q467898","display_name":"Insulation system","level":2,"score":0.5138759613037109},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5129091739654541},{"id":"https://openalex.org/C149808339","wikidata":"https://www.wikidata.org/wiki/Q5319019","display_name":"Dynamic simulation","level":2,"score":0.4653160572052002},{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.44927582144737244},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.44864824414253235},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.4362645745277405},{"id":"https://openalex.org/C2777154459","wikidata":"https://www.wikidata.org/wiki/Q2429341","display_name":"Heating system","level":2,"score":0.4141121804714203},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.37762966752052307},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.33576762676239014},{"id":"https://openalex.org/C107766110","wikidata":"https://www.wikidata.org/wiki/Q973879","display_name":"Vacuum insulated panel","level":4,"score":0.29615288972854614},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.23541122674942017},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.2114052176475525},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.19858607649803162},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.11753204464912415},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11594679951667786},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.08621358871459961},{"id":"https://openalex.org/C2779227376","wikidata":"https://www.wikidata.org/wiki/Q6505497","display_name":"Layer (electronics)","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":5,"locations":[{"id":"doi:10.1016/j.enbuild.2018.05.051","doi":"https://doi.org/10.1016/j.enbuild.2018.05.051","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.enbuild.2018.05.051","pdf_url":"https://www.sciencedirect.com/science/article/pii/S0378778818306601/pdf","source":{"id":"https://openalex.org/S6846437","display_name":"Energy and Buildings","issn_l":"0378-7788","issn":["0378-7788","1872-6178"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-3","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy and Buildings","raw_type":"journal-article"},{"id":"pmh:oai:pure.tue.nl:openaire/63b59386-000c-408d-9b4a-52d4fa911861","doi":null,"is_oa":true,"landing_page_url":"https://research.tue.nl/en/publications/63b59386-000c-408d-9b4a-52d4fa911861","pdf_url":null,"source":{"id":"https://openalex.org/S4406922641","display_name":"TU/e Research Portal","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Koenders, S J M, Loonen, R C G M & Hensen, J L M 2018, 'Investigating the potential of a closed-loop dynamic insulation system for opaque building elements', Energy and Buildings, vol. 173, pp. 409-427. https://doi.org/10.1016/j.enbuild.2018.05.051","raw_type":"info:eu-repo/semantics/article"},{"id":"pmh:900562","doi":null,"is_oa":false,"landing_page_url":"http://library.tue.nl/csp/dare/LinkToRepository.csp?recordnumber=900562","pdf_url":null,"source":{"id":"https://openalex.org/S4406922641","display_name":"TU/e Research Portal","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ISSN:0378-7788","raw_type":"Article / Letter to the editor"},{"id":"pmh:oai:library.tue.nl:900562","doi":null,"is_oa":false,"landing_page_url":"http://repository.tue.nl/900562","pdf_url":null,"source":{"id":"https://openalex.org/S4406922641","display_name":"TU/e Research Portal","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ISSN:0378-7788","raw_type":"Article / Letter to the editor"},{"id":"pmh:tue:oai:pure.tue.nl:publications/63b59386-000c-408d-9b4a-52d4fa911861","doi":null,"is_oa":true,"landing_page_url":"https://research.tue.nl/nl/publications/63b59386-000c-408d-9b4a-52d4fa911861","pdf_url":null,"source":{"id":"https://openalex.org/S4406922641","display_name":"TU/e Research Portal","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Energy and Buildings, 173, 409 - 427. Elsevier","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"doi:10.1016/j.enbuild.2018.05.051","doi":"https://doi.org/10.1016/j.enbuild.2018.05.051","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.enbuild.2018.05.051","pdf_url":"https://www.sciencedirect.com/science/article/pii/S0378778818306601/pdf","source":{"id":"https://openalex.org/S6846437","display_name":"Energy and Buildings","issn_l":"0378-7788","issn":["0378-7788","1872-6178"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-3","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy and Buildings","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.9090999960899353,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.75,"id":"https://metadata.un.org/sdg/13","display_name":"Climate action"},{"score":0.5142999887466431,"id":"https://metadata.un.org/sdg/11","display_name":"Sustainable cities and communities"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2807477463.pdf","grobid_xml":"https://content.openalex.org/works/W2807477463.grobid-xml"},"referenced_works_count":48,"referenced_works":["https://openalex.org/W1119898045","https://openalex.org/W1596629709","https://openalex.org/W1967983164","https://openalex.org/W1985686610","https://openalex.org/W1990213279","https://openalex.org/W2012509317","https://openalex.org/W2019553510","https://openalex.org/W2028440375","https://openalex.org/W2036753811","https://openalex.org/W2045889847","https://openalex.org/W2047772009","https://openalex.org/W2055086487","https://openalex.org/W2055254031","https://openalex.org/W2061316387","https://openalex.org/W2074656965","https://openalex.org/W2078641000","https://openalex.org/W2080952265","https://openalex.org/W2081402701","https://openalex.org/W2085873302","https://openalex.org/W2088275107","https://openalex.org/W2092744389","https://openalex.org/W2109400650","https://openalex.org/W2118568687","https://openalex.org/W2138237504","https://openalex.org/W2173842440","https://openalex.org/W2216523062","https://openalex.org/W2223895996","https://openalex.org/W2319287515","https://openalex.org/W2335571116","https://openalex.org/W2475835997","https://openalex.org/W2491952765","https://openalex.org/W2496924023","https://openalex.org/W2514127924","https://openalex.org/W2562614592","https://openalex.org/W2565866447","https://openalex.org/W2587230333","https://openalex.org/W2598100221","https://openalex.org/W2599895900","https://openalex.org/W2748501625","https://openalex.org/W2762387909","https://openalex.org/W2765146675","https://openalex.org/W2784300846","https://openalex.org/W2790793167","https://openalex.org/W4251057234","https://openalex.org/W4285719527","https://openalex.org/W6720889403","https://openalex.org/W6959782044","https://openalex.org/W7064621410"],"related_works":["https://openalex.org/W4283379948","https://openalex.org/W7019908728","https://openalex.org/W2887416249","https://openalex.org/W7162145198","https://openalex.org/W4229455619","https://openalex.org/W4308341605","https://openalex.org/W168957465","https://openalex.org/W2614643833","https://openalex.org/W4200499396","https://openalex.org/W4386422617"],"abstract_inverted_index":{"The":[0],"extensive":[1],"use":[2],"of":[3,53,57,73,98,113,135,179,201],"thermal":[4,23,133,180],"insulation":[5,28,62,76,122,156,187],"in":[6,15,79,92,171,198],"low-energy":[7],"dwellings":[8],"makes":[9],"them":[10],"susceptible":[11],"to":[12,69,107,157],"heat":[13],"trapping":[14],"warmer":[16],"periods.":[17],"Construction":[18],"elements":[19],"with":[20,94,161],"dynamically":[21],"adjustable":[22],"transmittance":[24],"properties,":[25],"so-called":[26],"dynamic":[27,61,75,121,155,186],"systems,":[29,149],"can":[30,89,124,189],"be":[31,90],"a":[32,54,85,136,158,162,176],"promising":[33],"solution":[34],"for":[35,46,193],"reducing":[36],"this":[37,49],"overheating":[38],"problem,":[39],"while":[40,140],"simultaneously":[41],"lowering":[42],"the":[43,51,71,74,95,99,109,114,120,126,131,172,184,191,199],"energy":[44,127,144],"consumption":[45,128],"heating.":[47],"In":[48],"paper,":[50],"performance":[52,72,112],"novel":[55],"type":[56],"closed-loop":[58,185],"forced":[59],"convective":[60],"system":[63,123,188,197],"is":[64,77,182],"investigated.":[65],"A":[66],"simulation":[67],"model":[68],"predict":[70],"developed":[78],"EnergyPlus.":[80],"First":[81],"results":[82],"show":[83],"that":[84,119],"ninefold":[86],"higher":[87],"U-value":[88],"achieved":[91],"comparison":[93],"insulating":[96],"state":[97],"system.":[100,115],"Multiple":[101],"case":[102],"studies":[103],"have":[104],"been":[105],"analysed":[106],"study":[108],"behaviour":[110],"and":[111,129,166,204],"It":[116],"was":[117],"found":[118],"reduce":[125],"increase":[130],"indoor":[132],"comfort":[134],"typical":[137],"residential":[138],"building,":[139],"using":[141],"less":[142],"auxiliary":[143],"than":[145],"comparable":[146],"passive":[147],"cooling":[148,196],"such":[150],"as":[151],"night":[152],"ventilation.":[153],"Applying":[154],"fa\u00e7ade":[159],"construction":[160],"heavyweight":[163],"interior":[164],"partition":[165,169],"lightweight":[167],"exterior":[168],"resulted":[170],"best":[173],"performance.":[174],"If":[175],"small":[177],"period":[178],"discomfort":[181],"allowed,":[183],"obviate":[190],"need":[192],"an":[194],"active":[195],"climates":[200],"Helsinki,":[202],"Amsterdam":[203],"Stuttgart.":[205]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2807477463","counts_by_year":[{"year":2026,"cited_by_count":11},{"year":2025,"cited_by_count":8},{"year":2024,"cited_by_count":13},{"year":2023,"cited_by_count":10},{"year":2022,"cited_by_count":11},{"year":2021,"cited_by_count":10},{"year":2020,"cited_by_count":6},{"year":2019,"cited_by_count":6},{"year":2018,"cited_by_count":6}],"updated_date":"2026-11-17T12:49:18.490984","created_date":"2018-06-13T00:00:00"}