{"id":"https://openalex.org/W2805876403","doi":"https://doi.org/10.1109/tpel.2018.2844021","title":"Variable on-Time Control Scheme for the Secondary-Side Controlled Flyback Converter","display_name":"Variable on-Time Control Scheme for the Secondary-Side Controlled Flyback Converter","publication_year":2018,"publication_date":"2018-06-04","ids":{"openalex":"https://openalex.org/W2805876403","doi":"https://doi.org/10.1109/tpel.2018.2844021","mag":"2805876403"},"language":"en","primary_location":{"id":"doi:10.1109/tpel.2018.2844021","doi":"https://doi.org/10.1109/tpel.2018.2844021","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpel.2018.2844021","pdf_url":null,"source":{"id":"https://openalex.org/S29875816","display_name":"IEEE Transactions on Power Electronics","issn_l":"0885-8993","issn":["0885-8993","1941-0107"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-3","norway-2","poland-200","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Electronics","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5029081258","display_name":"Alexander Connaughton","orcid":"https://orcid.org/0000-0002-3806-0223","observed_orcids":["https://orcid.org/0000-0002-3806-0223"]},"institutions":[{"id":"https://openalex.org/I4092182","display_name":"Graz University of Technology","ror":"https://ror.org/00d7xrm67","country_code":"AT","type":"education","lineage":["https://openalex.org/I4092182"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"Alexander Connaughton","raw_affiliation_strings":["Electric Drives and Machines Institute, Graz University of Technology, Graz, Austria"],"raw_orcid":"https://orcid.org/0000-0002-3806-0223","affiliations":[{"raw_affiliation_string":"Electric Drives and Machines Institute, Graz University of Technology, Graz, Austria","institution_ids":["https://openalex.org/I4092182"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049863072","display_name":"Arash Pake Talei","orcid":"https://orcid.org/0000-0001-7264-1446","observed_orcids":["https://orcid.org/0000-0001-7264-1446"]},"institutions":[{"id":"https://openalex.org/I4210131793","display_name":"Infineon Technologies (Austria)","ror":"https://ror.org/03msng824","country_code":"AT","type":"company","lineage":["https://openalex.org/I137594350","https://openalex.org/I4210131793"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"Arash Pake Talei","raw_affiliation_strings":["Infineon Technologies Austria AG, Villach, Austria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Infineon Technologies Austria AG, Villach, Austria","institution_ids":["https://openalex.org/I4210131793"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5055977701","display_name":"Kennith Kin Leong","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210131793","display_name":"Infineon Technologies (Austria)","ror":"https://ror.org/03msng824","country_code":"AT","type":"company","lineage":["https://openalex.org/I137594350","https://openalex.org/I4210131793"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"Kennith Kin Leong","raw_affiliation_strings":["Infineon Technologies Austria AG, Villach, Austria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Infineon Technologies Austria AG, Villach, Austria","institution_ids":["https://openalex.org/I4210131793"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010644362","display_name":"Klaus Krischan","orcid":"https://orcid.org/0000-0003-0181-6792","observed_orcids":["https://orcid.org/0000-0003-0181-6792"]},"institutions":[{"id":"https://openalex.org/I4092182","display_name":"Graz University of Technology","ror":"https://ror.org/00d7xrm67","country_code":"AT","type":"education","lineage":["https://openalex.org/I4092182"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"Klaus Krischan","raw_affiliation_strings":["Electric Drives and Machines Institute, Graz University of Technology, Graz, Austria"],"raw_orcid":"https://orcid.org/0000-0003-0181-6792","affiliations":[{"raw_affiliation_string":"Electric Drives and Machines Institute, Graz University of Technology, Graz, Austria","institution_ids":["https://openalex.org/I4092182"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5082448527","display_name":"Annette Muetze","orcid":"https://orcid.org/0000-0002-9254-3744","observed_orcids":["https://orcid.org/0000-0002-9254-3744"]},"institutions":[{"id":"https://openalex.org/I4092182","display_name":"Graz University of Technology","ror":"https://ror.org/00d7xrm67","country_code":"AT","type":"education","lineage":["https://openalex.org/I4092182"]}],"countries":["AT"],"is_corresponding":false,"raw_author_name":"Annette Muetze","raw_affiliation_strings":["Electric Drives and Machines Institute, Graz University of Technology, Graz, Austria"],"raw_orcid":"https://orcid.org/0000-0002-9254-3744","affiliations":[{"raw_affiliation_string":"Electric Drives and Machines Institute, Graz University of Technology, Graz, Austria","institution_ids":["https://openalex.org/I4092182"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":0.6687,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.66647431,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":"34","issue":"3","first_page":"2416","last_page":"2426"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12898","display_name":"Induction Heating and Inverter Technology","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flyback-converter","display_name":"flyback converter","score":0.8930000066757202},{"id":"https://openalex.org/keywords/secondary-side-control","display_name":"secondary-side control","score":0.9319999814033508},{"id":"https://openalex.org/keywords/constant-switching-frequency","display_name":"constant switching frequency","score":0.9089999794960022},{"id":"https://openalex.org/keywords/synchronous-rectification","display_name":"synchronous rectification","score":0.8600000143051147},{"id":"https://openalex.org/keywords/converter-efficiency","display_name":"converter efficiency","score":0.5410000085830688},{"id":"https://openalex.org/keywords/output-ripple","display_name":"output voltage ripple","score":0.7020000219345093}],"concepts":[{"id":"https://openalex.org/C50942859","wikidata":"https://www.wikidata.org/wiki/Q4967193","display_name":"Rectification","level":3,"score":0.7176923155784607},{"id":"https://openalex.org/C17321440","wikidata":"https://www.wikidata.org/wiki/Q184909","display_name":"Flyback transformer","level":4,"score":0.6846415400505066},{"id":"https://openalex.org/C2779599953","wikidata":"https://www.wikidata.org/wiki/Q1776117","display_name":"Ripple","level":3,"score":0.6713087558746338},{"id":"https://openalex.org/C144534570","wikidata":"https://www.wikidata.org/wiki/Q5325","display_name":"Inductor","level":3,"score":0.5944992899894714},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5806376934051514},{"id":"https://openalex.org/C103303742","wikidata":"https://www.wikidata.org/wiki/Q1293595","display_name":"Flyback converter","level":4,"score":0.5540157556533813},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5072943568229675},{"id":"https://openalex.org/C81081738","wikidata":"https://www.wikidata.org/wiki/Q55542","display_name":"Lossless compression","level":3,"score":0.46658045053482056},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4420253336429596},{"id":"https://openalex.org/C188198153","wikidata":"https://www.wikidata.org/wiki/Q1613840","display_name":"Limiting","level":2,"score":0.4308392107486725},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3538162112236023},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.34813570976257324},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3226458430290222},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.28179532289505005},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.22222787141799927},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.08173727989196777},{"id":"https://openalex.org/C78548338","wikidata":"https://www.wikidata.org/wiki/Q2493","display_name":"Data compression","level":2,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tpel.2018.2844021","doi":"https://doi.org/10.1109/tpel.2018.2844021","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpel.2018.2844021","pdf_url":null,"source":{"id":"https://openalex.org/S29875816","display_name":"IEEE Transactions on Power Electronics","issn_l":"0885-8993","issn":["0885-8993","1941-0107"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-3","norway-2","poland-200","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.875,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.6773999929428101,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1931968122","https://openalex.org/W2004786770","https://openalex.org/W2008460151","https://openalex.org/W2028052853","https://openalex.org/W2055238337","https://openalex.org/W2088414368","https://openalex.org/W2098147975","https://openalex.org/W2126223717","https://openalex.org/W2133124746","https://openalex.org/W2167675596","https://openalex.org/W2331200873","https://openalex.org/W2338572805","https://openalex.org/W2404966833","https://openalex.org/W2548240061","https://openalex.org/W2561796068","https://openalex.org/W2738565600","https://openalex.org/W2892452262","https://openalex.org/W6651265956"],"related_works":["https://openalex.org/W2111243702","https://openalex.org/W2738565600","https://openalex.org/W2135457948","https://openalex.org/W2384587822","https://openalex.org/W3006596884","https://openalex.org/W2167675596","https://openalex.org/W2088414368","https://openalex.org/W4295832169","https://openalex.org/W6930778816","https://openalex.org/W2270398448"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"an":[3],"analysis":[4],"of":[5,77],"a":[6,88],"novel":[7,89],"control":[8,36],"approach":[9,42],"for":[10,23,38],"the":[11,34,41,50],"secondary":[12],"side":[13],"controlled":[14],"flyback":[15],"concept,":[16,40],"along":[17],"with":[18,94],"improved":[19],"drain-source":[20],"voltage":[21],"sensing":[22,92],"more":[24],"precise":[25],"gate":[26],"signals":[27],"and":[28,59,86],"reduced":[29],"losses.":[30],"In":[31],"contrast":[32],"to":[33],"existing":[35],"scheme":[37],"this":[39],"presented":[43],"here":[44],"sustains":[45],"constant":[46],"switching":[47],"frequency":[48],"throughout":[49],"load":[51,73],"range":[52],"without":[53],"any":[54],"additional":[55],"hardware,":[56],"boosting":[57],"efficiency":[58,76],"simplifying":[60],"coupled":[61],"inductor":[62],"design":[63],"optimization.":[64],"A":[65],"65-W":[66],"demonstrator":[67],"shows":[68],"minimal":[69,95],"output":[70,80],"ripple":[71],"during":[72],"changes,":[74],"peak":[75],"89.90%,":[78],"natural":[79],"current":[81,97],"limiting":[82],"in":[83],"overload":[84],"conditions,":[85],"utilizes":[87],"lossless":[90],"synchronous-rectification":[91],"subcircuit":[93],"zero":[96],"crossing":[98],"delay.":[99]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2026-10-02T10:15:12.560889","created_date":"2018-06-13T00:00:00"}
