{"id":"https://openalex.org/W2802608529","doi":null,"title":"Condition Based Maintenance of Wind Turbines by 24/7 Monitoring of Oil Quality and Additive Consumption: Identification of Critical Operation Conditions and Determination of the Next Oil Change","display_name":"Condition Based Maintenance of Wind Turbines by 24/7 Monitoring of Oil Quality and Additive Consumption: Identification of Critical Operation Conditions and Determination of the Next Oil Change","publication_year":2017,"publication_date":"2017-03-20","ids":{"openalex":"https://openalex.org/W2802608529","mag":"2802608529"},"language":"en","primary_location":{"id":"mag:2802608529","doi":null,"is_oa":false,"landing_page_url":"http://www.flogen.org/sips2017/paper-2-81.html","pdf_url":null,"source":{"id":"https://openalex.org/S4306498232","display_name":"2017-Sustainable Industrial Processing Summit","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"2017-Sustainable Industrial Processing Summit","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5049580978","display_name":"Manfred Mauntz","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Manfred Mauntz","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5042183439","display_name":"J\u00f6rn Peuser","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J\u00f6rn Peuser","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.23468715,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":"2","issue":null,"first_page":"138","last_page":"148"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.760699987411499,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.760699987411499,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.06700000166893005,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11557","display_name":"Lubricants and Their Additives","score":0.05040000006556511,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wind-turbines","display_name":"wind turbines","score":0.8479999899864197},{"id":"https://openalex.org/keywords/condition-based-maintenance","display_name":"condition-based maintenance","score":0.8360000252723694},{"id":"https://openalex.org/keywords/oil-condition-monitoring","display_name":"oil condition monitoring","score":0.824999988079071},{"id":"https://openalex.org/keywords/gearbox","display_name":"gearbox","score":0.3959999978542328},{"id":"https://openalex.org/keywords/wear-index","display_name":"wear index","score":0.5720000267028809},{"id":"https://openalex.org/keywords/oil-change-intervals","display_name":"oil change intervals","score":0.6290000081062317},{"id":"https://openalex.org/keywords/electrical-conductivity","display_name":"electrical conductivity","score":0.8640000224113464},{"id":"https://openalex.org/keywords/dielectric-constant","display_name":"dielectric constant","score":0.906000018119812},{"id":"https://openalex.org/keywords/oil-temperature","display_name":"oil temperature","score":0.9850000143051147},{"id":"https://openalex.org/keywords/predictive-maintenance","display_name":"predictive maintenance","score":0.6309999823570251},{"id":"https://openalex.org/keywords/vibration-monitoring","display_name":"vibration monitoring","score":0.7160000205039978},{"id":"https://openalex.org/keywords/onshore-wind-turbines","display_name":"onshore wind turbines","score":0.5960000157356262}],"concepts":[{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.774894118309021},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6630985736846924},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.6265344023704529},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.5999873876571655},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5548487901687622},{"id":"https://openalex.org/C2776907094","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Condition-based maintenance","level":2,"score":0.5318272709846497},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.47705259919166565},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.44448351860046387},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.4393303394317627},{"id":"https://openalex.org/C2778814095","wikidata":"https://www.wikidata.org/wiki/Q6736790","display_name":"Maintenance actions","level":2,"score":0.418140172958374},{"id":"https://openalex.org/C199104240","wikidata":"https://www.wikidata.org/wiki/Q118291","display_name":"Marine engineering","level":1,"score":0.39521920680999756},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.38511133193969727},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3131951093673706},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.17257988452911377},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.12449932098388672},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09027177095413208},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2802608529","doi":null,"is_oa":false,"landing_page_url":"http://www.flogen.org/sips2017/paper-2-81.html","pdf_url":null,"source":{"id":"https://openalex.org/S4306498232","display_name":"2017-Sustainable Industrial Processing Summit","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"2017-Sustainable Industrial Processing Summit","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8485000133514404,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.5378999710083008,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2621066936","https://openalex.org/W1982428420","https://openalex.org/W2969285697","https://openalex.org/W2795155803","https://openalex.org/W2365155266","https://openalex.org/W2309360496","https://openalex.org/W2076836529","https://openalex.org/W2247166815","https://openalex.org/W1812310435","https://openalex.org/W2970527641"],"abstract_inverted_index":{"The":[0,50,102],"demand":[1],"for":[2,119],"wind":[3,26,59,125,164],"energy":[4],"grows":[5],"at":[6],"exponential":[7],"rates.":[8],"At":[9],"the":[10,22,47,58,83,86,90,96,106,130,137],"same":[11],"time,":[12],"improving":[13],"reliability":[14],"and":[15,18,71,89,112],"reduced":[16],"operation":[17,69],"maintenance":[19,28,149],"costs":[20],"are":[21,172],"key":[23],"priorities":[24],"in":[25,115],"turbine":[27,60,165],"strategies.":[29],"This":[30],"paper":[31],"provides":[32],"information":[33],"about":[34],"a":[35,44,79,120,133],"novel":[36],"online":[37],"oil":[38,74,91,139],"condition":[39],"monitoring":[40,122,171],"system":[41,53],"to":[42,46,123,168],"recommend":[43],"solution":[45],"mentioned":[48],"priorities.":[49],"presented":[51],"sensor":[52],"enables":[54,132],"damage":[55,156],"prevention":[56],"of":[57,67,82,105,161],"gear-box":[61],"by":[62,78,141],"an":[63,72,162],"advanced":[64],"warning":[65],"time":[66],"critical":[68],"conditions,":[70],"enhanced":[73],"exchange":[75],"interval":[76],"realized":[77],"precise":[80],"measurement":[81],"electrical":[84],"conductivity,":[85],"relative":[87],"permittivity":[88],"temperature.":[92],"A":[93],"new":[94],"parameter,":[95],"WearSens\u00ae":[97],"Index":[98],"(WSi)":[99],"is":[100],"introduced.":[101],"mathematical":[103],"model":[104],"WSi":[107,131,159],"combines":[108],"all":[109],"measured":[110],"values":[111],"its":[113],"gradients":[114],"one":[116],"single":[117],"parameter":[118],"comprehensive":[121],"prevent":[124],"turbines":[126],"from":[127],"damage.":[128],"Furthermore,":[129],"long-term":[134],"prognosis":[135],"on":[136],"next":[138],"change":[140],"24/7":[142],"server":[143],"data":[144],"logging.":[145],"Corrective":[146],"procedures":[147],"and/or":[148],"can":[150],"be":[151],"carried":[152],"out":[153],"before":[154],"actual":[155],"occurs.":[157],"First":[158],"results":[160],"onshore":[163],"installation":[166],"compared":[167],"traditional":[169],"vibration":[170],"shown.":[173]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":1}],"updated_date":"2025-10-10T17:16:08.811792","created_date":"2018-05-17T00:00:00"}
