{"id":"https://openalex.org/W2784366017","doi":"https://doi.org/10.2172/1416954","title":"Field and Laboratory Testing of Approaches to Smart Whole-House Mechanical Ventilation Control","display_name":"Field and Laboratory Testing of Approaches to Smart Whole-House Mechanical Ventilation Control","publication_year":2018,"publication_date":"2018-01-01","ids":{"openalex":"https://openalex.org/W2784366017","doi":"https://doi.org/10.2172/1416954","mag":"2784366017"},"language":"en","primary_location":{"id":"doi:10.2172/1416954","doi":"https://doi.org/10.2172/1416954","is_oa":false,"landing_page_url":"https://doi.org/10.2172/1416954","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Golden Field Office, Golden, CO (United States)","raw_type":"report"},"volume":null,"type":"report","is_traditional":false,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://stars.library.ucf.edu/fsec/63","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5085621044","display_name":"ERIC C. MARTIN","orcid":"https://orcid.org/0000-0002-7171-548X","observed_orcids":["https://orcid.org/0000-0002-7171-548X"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Eric Martin","raw_affiliation_strings":["Florida Solar Energy Center, Cocoa, FL (United States)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Florida Solar Energy Center, Cocoa, FL (United States)","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5147765908","display_name":"Energy Efficiency Office. Building Technologies Office USDOE Office of Energy Efficiency and Renewable Energy (EERE)","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office","raw_affiliation_strings":["Florida Solar Energy Center, Cocoa, FL (United States)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Florida Solar Energy Center, Cocoa, FL (United States)","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5020945523","display_name":"Karen Fenaughty","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Karen Fenaughty","raw_affiliation_strings":["Florida Solar Energy Center, Cocoa, FL (United States)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Florida Solar Energy Center, Cocoa, FL (United States)","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5129883745","display_name":"Danny Parker","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I72951846","display_name":"Washington State University","ror":"https://ror.org/05dk0ce17","country_code":"US","type":"education","lineage":["https://openalex.org/I72951846"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Danny Parker","raw_affiliation_strings":["Florida Solar Energy Center, Cocoa, FL (United States)","Washington State Univ., Pullman, WA (United States)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Florida Solar Energy Center, Cocoa, FL (United States)","institution_ids":[]},{"raw_affiliation_string":"Washington State Univ., Pullman, WA (United States)","institution_ids":["https://openalex.org/I72951846"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113814826","display_name":"Michael Lubliner","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I72951846","display_name":"Washington State University","ror":"https://ror.org/05dk0ce17","country_code":"US","type":"education","lineage":["https://openalex.org/I72951846"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Michael Lubliner","raw_affiliation_strings":["Washington State Univ., Pullman, WA (United States)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Washington State Univ., Pullman, WA (United States)","institution_ids":["https://openalex.org/I72951846"]}]},{"author_position":"last","author":{"id":null,"display_name":"Luke Howard","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I72951846","display_name":"Washington State University","ror":"https://ror.org/05dk0ce17","country_code":"US","type":"education","lineage":["https://openalex.org/I72951846"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Luke Howard","raw_affiliation_strings":["Washington State Univ., Pullman, WA (United States)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Washington State Univ., Pullman, WA (United States)","institution_ids":["https://openalex.org/I72951846"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.5590999722480774,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.5590999722480774,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.40549999475479126,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.016300000250339508,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/indoor-air-quality","display_name":"indoor air quality","score":0.9940000176429749},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"energy consumption","score":0.5550000071525574},{"id":"https://openalex.org/keywords/occupant-comfort","display_name":"occupant comfort","score":0.8429999947547913},{"id":"https://openalex.org/keywords/heating-and-cooling-loads","display_name":"heating and cooling loads","score":0.8019999861717224}],"concepts":[{"id":"https://openalex.org/C206145494","wikidata":"https://www.wikidata.org/wiki/Q4654236","display_name":"ASHRAE 90.1","level":2,"score":0.8678958415985107},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.786369800567627},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.6925042867660522},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5114961862564087},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.4905216097831726},{"id":"https://openalex.org/C187819001","wikidata":"https://www.wikidata.org/wiki/Q187665","display_name":"Thermostat","level":2,"score":0.4172719419002533},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3568917512893677},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.35383912920951843},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.19664517045021057},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.15796226263046265},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.09254169464111328},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.2172/1416954","doi":"https://doi.org/10.2172/1416954","is_oa":false,"landing_page_url":"https://doi.org/10.2172/1416954","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Golden Field Office, Golden, CO (United States)","raw_type":"report"},{"id":"pmh:oai:stars.library.ucf.edu:fsec-1062","doi":null,"is_oa":true,"landing_page_url":"https://stars.library.ucf.edu/fsec/63","pdf_url":null,"source":{"id":"https://openalex.org/S4210172555","display_name":"Journal of International Crisis and Risk Communication Research","issn_l":"2576-0017","issn":["2576-0017","2576-0025"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","vabb-shw"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"FSEC Energy Research Center\u00ae","raw_type":"text"},{"id":"pmh:oai:osti.gov:1416954","doi":null,"is_oa":true,"landing_page_url":"https://www.osti.gov/biblio/1416954","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":{"id":"pmh:oai:stars.library.ucf.edu:fsec-1062","doi":null,"is_oa":true,"landing_page_url":"https://stars.library.ucf.edu/fsec/63","pdf_url":null,"source":{"id":"https://openalex.org/S4210172555","display_name":"Journal of International Crisis and Risk Communication Research","issn_l":"2576-0017","issn":["2576-0017","2576-0025"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","vabb-shw"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"FSEC Energy Research Center\u00ae","raw_type":"text"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.75,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/3","score":0.4000000059604645,"display_name":"Good health and well-being"}],"study_designs":[],"awards":[{"id":"https://openalex.org/G8824359922","display_name":"BUILDING AMERICA PARTNERSHIP FOR IMPROVED RESIDENTIAL CONSTRUCTION (BA-PIRC)","funder_award_id":"DEEE0007056","funder_id":"https://openalex.org/F4320306084","funder_display_name":"U.S. Department of Energy"}],"funders":[{"id":"https://openalex.org/F4320306084","display_name":"U.S. Department of Energy","ror":"https://ror.org/01bj3aw27"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2947692928","https://openalex.org/W4285663097","https://openalex.org/W2780282308","https://openalex.org/W2144882360","https://openalex.org/W2990038327","https://openalex.org/W7056375203","https://openalex.org/W7117160817","https://openalex.org/W4409222514","https://openalex.org/W6996377507","https://openalex.org/W7081922226"],"abstract_inverted_index":{"Whole-house":[0],"mechanical":[1,69],"ventilation":[2,58,70],"is":[3],"a":[4,8,32],"critical":[5],"component":[6],"to":[7,19,41,72,89],"comprehensive":[9],"strategy":[10],"for":[11],"good":[12],"indoor":[13,82],"air":[14],"quality":[15],"(IAQ).":[16],"However,":[17],"due":[18],"lack":[20],"of":[21,34,81],"integration":[22],"with":[23],"standard":[24],"heating":[25,75],"and":[26,29,47,51,65,84],"cooling":[27,77],"systems,":[28],"perceptions":[30],"from":[31],"portion":[33],"the":[35,74],"homebuilding":[36],"industry":[37],"about":[38],"risks":[39],"related":[40],"increased":[42,45],"energy":[43,62],"use,":[44],"cost,":[46],"decreased":[48],"comfort,":[49,64],"voluntary":[50],"code-required":[52],"adoption":[53],"varies":[54],"amongst":[55],"regions.":[56],"Smart":[57],"controls":[59],"(SVC)":[60],"balance":[61],"consumption,":[63],"IAQ":[66,86],"by":[67],"optimizing":[68],"operation":[71],"reduce":[73],"and/or":[76],"loads,":[78],"improve":[79],"management":[80],"moisture,":[83],"maintain":[85],"equivalence":[87],"according":[88],"ASHRAE":[90],"62.2.":[91]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1}],"updated_date":"2026-11-08T12:12:28.789561","created_date":"2018-02-02T00:00:00"}
