{"id":"https://openalex.org/W2768280807","doi":"https://doi.org/10.1109/ecce.2017.8096767","title":"A series-stacked architecture with 4-to-1 GaN-based isolated converters for high-efficiency data center power delivery","display_name":"A series-stacked architecture with 4-to-1 GaN-based isolated converters for high-efficiency data center power delivery","publication_year":2017,"publication_date":"2017-10-01","ids":{"openalex":"https://openalex.org/W2768280807","doi":"https://doi.org/10.1109/ecce.2017.8096767","mag":"2768280807"},"language":"en","primary_location":{"id":"doi:10.1109/ecce.2017.8096767","doi":"https://doi.org/10.1109/ecce.2017.8096767","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ecce.2017.8096767","pdf_url":null,"source":{"id":"https://openalex.org/S4363604350","display_name":"IEEE Energy Conversion Congress and Exposition (ECCE)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE Energy Conversion Congress and Exposition (ECCE)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101959000","display_name":"Yizhe Zhang","orcid":"https://orcid.org/0000-0002-9599-7995","observed_orcids":["https://orcid.org/0000-0002-9599-7995"]},"institutions":[{"id":"https://openalex.org/I157725225","display_name":"University of Illinois Urbana-Champaign","ror":"https://ror.org/047426m28","country_code":"US","type":"education","lineage":["https://openalex.org/I157725225"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yizhe Zhang","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois","institution_ids":["https://openalex.org/I157725225"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5091367642","display_name":"Enver Candan","orcid":"https://orcid.org/0000-0003-3463-0513","observed_orcids":["https://orcid.org/0000-0003-3463-0513"]},"institutions":[{"id":"https://openalex.org/I157725225","display_name":"University of Illinois Urbana-Champaign","ror":"https://ror.org/047426m28","country_code":"US","type":"education","lineage":["https://openalex.org/I157725225"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Enver Candan","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois","institution_ids":["https://openalex.org/I157725225"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5043348919","display_name":"Robert C. N. Pilawa-Podgurski","orcid":"https://orcid.org/0000-0002-5360-5906","observed_orcids":["https://orcid.org/0000-0002-5360-5906"]},"institutions":[{"id":"https://openalex.org/I157725225","display_name":"University of Illinois Urbana-Champaign","ror":"https://ror.org/047426m28","country_code":"US","type":"education","lineage":["https://openalex.org/I157725225"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Robert C. N. Pilawa-Podgurski","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois","institution_ids":["https://openalex.org/I157725225"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I157725225"],"apc_list":null,"apc_paid":null,"fwci":1.5523,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.80897988,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"4467","last_page":"4474"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11248","display_name":"Advanced Power Amplifier Design","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/differential-power-processing","display_name":"differential power processing","score":0.7279999852180481},{"id":"https://openalex.org/keywords/gan-switches","display_name":"GaN switches","score":0.8690000176429749},{"id":"https://openalex.org/keywords/isolated-dc-dc-converter","display_name":"isolated DC-DC converter","score":0.8709999918937683},{"id":"https://openalex.org/keywords/server-power-supply","display_name":"server power supply","score":0.7360000014305115},{"id":"https://openalex.org/keywords/high-efficiency-power-conversion","display_name":"high-efficiency power conversion","score":0.6769999861717224},{"id":"https://openalex.org/keywords/energy-efficiency","display_name":"energy efficiency","score":0.43700000643730164}],"concepts":[{"id":"https://openalex.org/C93996380","wikidata":"https://www.wikidata.org/wiki/Q44127","display_name":"Server","level":2,"score":0.8624599575996399},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.7479975819587708},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6417070031166077},{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.6366556286811829},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.49980926513671875},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4851242005825043},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.4440484046936035},{"id":"https://openalex.org/C2776266606","wikidata":"https://www.wikidata.org/wiki/Q476482","display_name":"Test bench","level":2,"score":0.41250890493392944},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.30801764130592346},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.2815157473087311},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2609536945819855},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21924540400505066},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ecce.2017.8096767","doi":"https://doi.org/10.1109/ecce.2017.8096767","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ecce.2017.8096767","pdf_url":null,"source":{"id":"https://openalex.org/S4363604350","display_name":"IEEE Energy Conversion Congress and Exposition (ECCE)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE Energy Conversion Congress and Exposition (ECCE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9853000044822693,"id":"https://metadata.un.org/sdg/7"},{"display_name":"Industry, innovation and infrastructure","score":0.8970999717712402,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W634192751","https://openalex.org/W1481303361","https://openalex.org/W1491535937","https://openalex.org/W1945291119","https://openalex.org/W1961152141","https://openalex.org/W2024480405","https://openalex.org/W2062696532","https://openalex.org/W2098376039","https://openalex.org/W2118203870","https://openalex.org/W2141401705","https://openalex.org/W2202154799","https://openalex.org/W2338020636","https://openalex.org/W2553242139","https://openalex.org/W2563970721","https://openalex.org/W2614416023","https://openalex.org/W2736578080"],"related_works":["https://openalex.org/W2758404764","https://openalex.org/W3033989597","https://openalex.org/W2202154799","https://openalex.org/W2326390790","https://openalex.org/W1945291119","https://openalex.org/W2208406004","https://openalex.org/W2944927379","https://openalex.org/W2614646572","https://openalex.org/W4415968985","https://openalex.org/W2553242139"],"abstract_inverted_index":{"Series-stacked":[0],"server":[1,38,94],"power":[2,18,28,68,95],"delivery":[3,19],"architectures":[4,59],"have":[5],"been":[6],"proposed":[7],"recently":[8],"that":[9],"can":[10,32],"achieve":[11,65],"much":[12],"higher":[13,77],"energy":[14],"efficiency":[15,130],"than":[16,79],"conventional":[17],"architectures.":[20,82],"When":[21],"servers":[22,42,115,135],"are":[23,43,116,136],"connected":[24],"in":[25,70,118],"series,":[26],"differential":[27],"processing":[29],"(DPP)":[30],"converters":[31,107],"be":[33],"used":[34,117],"to":[35,64,122],"regulate":[36],"the":[37,41,66,71,86,119,124,134],"voltages":[39],"when":[40],"consuming":[44],"different":[45],"amount":[46],"of":[47,88,126],"currents.":[48],"Server-to-bus":[49],"DPP":[50,58,72,81,91,106],"architecture":[51,92],"has":[52],"unique":[53],"advantages":[54],"among":[55],"several":[56],"other":[57,80],"such":[60],"as":[61],"being":[62],"able":[63],"minimum":[67],"processed":[69],"converters,":[73],"and":[74],"having":[75],"a":[76,89,138],"reliability":[78],"This":[83],"work":[84],"presents":[85],"development":[87],"server-to-bus":[90,127],"for":[93],"delivery.":[96],"The":[97],"hardware":[98],"prototype":[99],"is":[100,131],"built":[101],"with":[102,108],"four":[103],"4-to-1":[104],"isolated":[105],"GaN":[109],"switches.":[110],"Four":[111],"12V":[112],"120W":[113],"Dell":[114],"bench":[120],"test":[121],"validate":[123],"operation":[125],"DPP.":[128],"98.99%":[129],"achieved":[132],"while":[133],"running":[137],"real-life":[139],"data":[140],"center":[141],"computational":[142],"load.":[143]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1}],"updated_date":"2026-10-16T09:59:22.235173","created_date":"2017-12-04T00:00:00"}