{"id":"https://openalex.org/W2761215449","doi":null,"title":"Analysis of energy and humidity performance of a system combining chilled-ceiling with desiccant cooling","display_name":"Analysis of energy and humidity performance of a system combining chilled-ceiling with desiccant cooling","publication_year":2002,"publication_date":"2002-01-01","ids":{"openalex":"https://openalex.org/W2761215449","mag":"2761215449"},"language":"en","primary_location":{"id":"pmh:oai:ira.lib.polyu.edu.hk:10397/11830","doi":null,"is_oa":false,"landing_page_url":"http://hdl.handle.net/10397/11830","pdf_url":null,"source":{"id":"https://openalex.org/S4306400205","display_name":"PolyU Institutional Research Archive (Hong Kong Polytechnic University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I14243506","host_organization_name":"Hong Kong Polytechnic University","host_organization_lineage":["https://openalex.org/I14243506"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Conference Paper"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5024240572","display_name":"Jianlei Niu","orcid":"https://orcid.org/0000-0002-1176-9179","observed_orcids":["https://orcid.org/0000-0002-1176-9179"]},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Jianlei Niu","raw_affiliation_strings":["The Hong Kong Polytechnic University"],"raw_orcid":"https://orcid.org/0000-0002-1176-9179","affiliations":[{"raw_affiliation_string":"The Hong Kong Polytechnic University","institution_ids":["https://openalex.org/I14243506"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100663890","display_name":"Li\u2010Zhi Zhang","orcid":"https://orcid.org/0000-0001-5768-2119","observed_orcids":["https://orcid.org/0000-0001-5768-2119"]},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Li\u2010Zhi Zhang","raw_affiliation_strings":["The Hong Kong Polytechnic University"],"raw_orcid":"https://orcid.org/0000-0001-5768-2119","affiliations":[{"raw_affiliation_string":"The Hong Kong Polytechnic University","institution_ids":["https://openalex.org/I14243506"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5069956691","display_name":"Huigang Zuo","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Huigang Zuo","raw_affiliation_strings":["The Hong Kong Polytechnic University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The Hong Kong Polytechnic University","institution_ids":["https://openalex.org/I14243506"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I14243506"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.44790942,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"195","last_page":"201"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":0.6615999937057495,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":0.6615999937057495,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.3253999948501587,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.0066999997943639755,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/chilled-ceiling","display_name":"chilled ceiling","score":0.925000011920929},{"id":"https://openalex.org/keywords/desiccant-cooling","display_name":"desiccant cooling","score":0.9559999704360962},{"id":"https://openalex.org/keywords/air-dehumidification","display_name":"air dehumidification","score":0.8149999976158142},{"id":"https://openalex.org/keywords/hot-humid-climate","display_name":"hot and humid climate","score":0.8989999890327454},{"id":"https://openalex.org/keywords/hvac-energy-consumption","display_name":"HVAC energy consumption","score":0.7559999823570251},{"id":"https://openalex.org/keywords/low-grade-heat-utilization","display_name":"low-grade heat utilization","score":0.7379999756813049}],"concepts":[{"id":"https://openalex.org/C37819138","wikidata":"https://www.wikidata.org/wiki/Q13221746","display_name":"Desiccant","level":2,"score":0.804602861404419},{"id":"https://openalex.org/C2777489069","wikidata":"https://www.wikidata.org/wiki/Q1589822","display_name":"Ceiling (cloud)","level":2,"score":0.778894305229187},{"id":"https://openalex.org/C123516432","wikidata":"https://www.wikidata.org/wiki/Q572309","display_name":"Chilled water","level":3,"score":0.6336671113967896},{"id":"https://openalex.org/C151420433","wikidata":"https://www.wikidata.org/wiki/Q180600","display_name":"Humidity","level":2,"score":0.6192988157272339},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5311385989189148},{"id":"https://openalex.org/C2993926350","wikidata":"https://www.wikidata.org/wiki/Q13221746","display_name":"Liquid desiccant","level":3,"score":0.49267059564590454},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.3737644553184509},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3145238757133484},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.26722252368927},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.2172321081161499},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.07847905158996582},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.06395977735519409}],"mesh":[],"locations_count":3,"locations":[{"id":"pmh:oai:ira.lib.polyu.edu.hk:10397/11830","doi":null,"is_oa":false,"landing_page_url":"http://hdl.handle.net/10397/11830","pdf_url":null,"source":{"id":"https://openalex.org/S4306400205","display_name":"PolyU Institutional Research Archive (Hong Kong Polytechnic University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I14243506","host_organization_name":"Hong Kong Polytechnic University","host_organization_lineage":["https://openalex.org/I14243506"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Conference Paper"},{"id":"pmh:oai:ira.lib.polyu.edu.hk:10397/56183","doi":null,"is_oa":false,"landing_page_url":"http://hdl.handle.net/10397/56183","pdf_url":null,"source":{"id":"https://openalex.org/S4306400205","display_name":"PolyU Institutional Research Archive (Hong Kong Polytechnic University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I14243506","host_organization_name":"Hong Kong Polytechnic University","host_organization_lineage":["https://openalex.org/I14243506"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Conference Paper"},{"id":"mag:2761215449","doi":null,"is_oa":false,"landing_page_url":"https://iifiir.org/fr/fridoc/20790","pdf_url":null,"source":{"id":"https://openalex.org/S2765075670","display_name":"ASHRAE winter conference papers","issn_l":"2378-2129","issn":["2378-2129"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4327983461","host_organization_name":"American Society of Heating, Refrigerating and Air-Conditioning Engineers","host_organization_lineage":["https://openalex.org/P4327983461"],"host_organization_lineage_names":["American Society of Heating, Refrigerating and Air-Conditioning Engineers"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"ASHRAE winter conference papers","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/13","score":0.9786999821662903,"display_name":"Climate action"},{"id":"https://metadata.un.org/sdg/7","score":0.75,"display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W32809074","https://openalex.org/W2466220790","https://openalex.org/W7010703926","https://openalex.org/W7020034926","https://openalex.org/W2476003916","https://openalex.org/W2956295980","https://openalex.org/W2997764102","https://openalex.org/W3120620422","https://openalex.org/W7071840630","https://openalex.org/W4297975917"],"abstract_inverted_index":{"An":[0],"HVAC":[1],"system":[2,52,81,128,180],"combining":[3],"chilled":[4,41,67],"ceiling":[5,68,134,154],"with":[6,57,69,83],"desiccant":[7,84,179],"cooling":[8,85],"(CC+DC)":[9],"is":[10,20,53,136],"proposed":[11],"for":[12,177],"hot":[13,143],"and":[14,32,55,66,95,126,144],"humid":[15,145,166],"climates":[16],"where":[17],"air":[18,26],"dehumidification":[19,73,125,149],"required":[21,137],"to":[22,33,89,111,130,138],"maintain":[23],"the":[24,35,46,51,104,124,131,162,178],"indoor":[25],"humidity":[27],"within":[28],"a":[29,79,112],"comfort":[30,105],"zone":[31,106],"reduce":[34,139],"risk":[36],"of":[37,50,91,107,133,173,187],"water":[38],"condensation":[39,140,163],"on":[40],"panels.":[42],"Through":[43],"hour-by-hour":[44],"simulations,":[45],"annual":[47,101,174],"energy":[48,93],"consumption":[49,94],"calculated":[54],"compared":[56,110],"two":[58],"other":[59],"systems:":[60],"conventional":[61,113],"constant":[62,114],"volume":[63,115],"all-air":[64,116],"(CAV)":[65],"air-handling":[70],"units":[71],"(AHU)":[72],"(CC+AHU).":[74],"The":[75,118],"results":[76,119],"indicate":[77,121],"that":[78,122],"chilled-ceiling":[80],"combined":[82],"could":[86,159,181],"save":[87],"up":[88],"30%o":[90],"primary":[92],"would":[96],"result":[97],"in":[98,103,142,157,165],"40%":[99],"more":[100,170],"hours":[102,176],"relative":[108],"humidity,":[109],"system.":[117],"also":[120],"starting":[123],"ventilation":[127],"prior":[129],"operation":[132,156],"panels":[135],"risks":[141],"climates.":[146,167],"However,":[147],"beginning":[148],"one":[150],"hour":[151],"earlier":[152],"than":[153,171],"panel":[155],"summer":[158],"completely":[160],"eliminate":[161],"problems":[164],"More":[168],"interestingly,":[169],"70%":[172],"operating":[175],"be":[182],"accomplished":[183],"using":[184],"low-grade":[185],"heat":[186],"less":[188],"them":[189],"80\u00b0C":[190],"(176\u00b0F).":[191]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2014,"cited_by_count":1}],"updated_date":"2026-11-09T13:22:03.289127","created_date":"2017-10-20T00:00:00"}
