{"id":"https://openalex.org/W2736043348","doi":null,"title":"Effects of CO 2 Exhaled and Human Metabolism on Comfort Conditions in Air-Conditioned Indoor Environment","display_name":"Effects of CO 2 Exhaled and Human Metabolism on Comfort Conditions in Air-Conditioned Indoor Environment","publication_year":2010,"publication_date":"2010-12-01","ids":{"openalex":"https://openalex.org/W2736043348","mag":"2736043348"},"language":"en","primary_location":{"id":"mag:2736043348","doi":null,"is_oa":false,"landing_page_url":"http://www.i-scholar.in/index.php/NEPT/article/view/112075","pdf_url":null,"source":{"id":"https://openalex.org/S2764514638","display_name":"Nature Environment and Pollution Technology","issn_l":"0972-6268","issn":["0972-6268","2395-3454"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-scientific","cwts-core","doaj","poland-20","russia-white-list-4"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Nature Environment and Pollution Technology","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5052201532","display_name":"P. Thirumal","orcid":"https://orcid.org/0000-0003-0055-4807","observed_orcids":["https://orcid.org/0000-0003-0055-4807"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"P. Thirumal","raw_affiliation_strings":["Deptt. of Mechanical Engineering, Govt. College of Engineering, Bargur-635 104"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Deptt. of Mechanical Engineering, Govt. College of Engineering, Bargur-635 104","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Sundaram Balasubramanian","orcid":"https://orcid.org/0000-0002-3355-6764","observed_orcids":["https://orcid.org/0000-0002-3355-6764"]},"institutions":[{"id":"https://openalex.org/I4400600945","display_name":"Anna University Regional Campus, Coimbatore","ror":"https://ror.org/057qyqy03","country_code":"IN","type":"education","lineage":["https://openalex.org/I4400600945"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sundaram Balasubramanian","raw_affiliation_strings":["Anna University, Coimbatore-641 047, T.N"],"raw_orcid":"https://orcid.org/0000-0002-3355-6764","affiliations":[{"raw_affiliation_string":"Anna University, Coimbatore-641 047, T.N","institution_ids":["https://openalex.org/I4400600945"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5028961900","display_name":"N. Shenbaga Vinayaga Moorthi","orcid":"https://orcid.org/0000-0003-2139-9295","observed_orcids":["https://orcid.org/0000-0003-2139-9295"]},"institutions":[{"id":"https://openalex.org/I33585257","display_name":"Anna University, Chennai","ror":"https://ror.org/01qhf1r47","country_code":"IN","type":"education","lineage":["https://openalex.org/I33585257"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"N. Shenbaga Vinayaga Moorthi","raw_affiliation_strings":["Dept. of Mechanical Engineering, Anna University, Tirunelveli, T. N"],"raw_orcid":"https://orcid.org/0000-0003-2139-9295","affiliations":[{"raw_affiliation_string":"Dept. of Mechanical Engineering, Anna University, Tirunelveli, T. N","institution_ids":["https://openalex.org/I33585257"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":575,"currency":"USD","value_usd":575},"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"9","issue":"4","first_page":"829","last_page":"835"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.5512999892234802,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.5512999892234802,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.43650001287460327,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10990","display_name":"Infection Control and Ventilation","score":0.0031999999191612005,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/exhaled-co2","display_name":"exhaled CO2","score":0.7149999737739563},{"id":"https://openalex.org/keywords/human-metabolism","display_name":"human metabolism","score":0.8849999904632568},{"id":"https://openalex.org/keywords/thermal-comfort","display_name":"thermal comfort","score":0.7379999756813049},{"id":"https://openalex.org/keywords/indoor-air-quality","display_name":"indoor air quality","score":0.8460000157356262},{"id":"https://openalex.org/keywords/ventilation-rate","display_name":"ventilation rate","score":0.656000018119812},{"id":"https://openalex.org/keywords/indoor-pollutants","display_name":"indoor pollutants","score":0.6269999742507935},{"id":"https://openalex.org/keywords/ashrae-standards","display_name":"ASHRAE standards","score":0.9089999794960022},{"id":"https://openalex.org/keywords/occupant-comfort","display_name":"occupant comfort","score":0.597000002861023}],"concepts":[{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.7054671049118042},{"id":"https://openalex.org/C206145494","wikidata":"https://www.wikidata.org/wiki/Q4654236","display_name":"ASHRAE 90.1","level":2,"score":0.6393229365348816},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.6143316030502319},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.5776193737983704},{"id":"https://openalex.org/C2987857752","wikidata":"https://www.wikidata.org/wiki/Q12147","display_name":"Human health","level":2,"score":0.5391201972961426},{"id":"https://openalex.org/C3017909875","wikidata":"https://www.wikidata.org/wiki/Q628858","display_name":"Working environment","level":2,"score":0.5180766582489014},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.5087044835090637},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.5011348724365234},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4569055140018463},{"id":"https://openalex.org/C82685317","wikidata":"https://www.wikidata.org/wiki/Q19829510","display_name":"Pollutant","level":2,"score":0.44433072209358215},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.34144139289855957},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33800244331359863},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3324016332626343},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.1582510769367218},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.10103797912597656},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.09219890832901001},{"id":"https://openalex.org/C99454951","wikidata":"https://www.wikidata.org/wiki/Q932068","display_name":"Environmental health","level":1,"score":0.08723142743110657},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2736043348","doi":null,"is_oa":false,"landing_page_url":"http://www.i-scholar.in/index.php/NEPT/article/view/112075","pdf_url":null,"source":{"id":"https://openalex.org/S2764514638","display_name":"Nature Environment and Pollution Technology","issn_l":"0972-6268","issn":["0972-6268","2395-3454"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-scientific","cwts-core","doaj","poland-20","russia-white-list-4"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Nature Environment and Pollution Technology","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3","score":0.5683000087738037}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2981103543","https://openalex.org/W3022325938","https://openalex.org/W4293766646","https://openalex.org/W2995395303","https://openalex.org/W4379883395","https://openalex.org/W2535228816","https://openalex.org/W4408379148","https://openalex.org/W3194390272","https://openalex.org/W4200130852","https://openalex.org/W2025695855"],"abstract_inverted_index":{"Thermal":[0],"and":[1,15,20,38,139,154],"atmospheric":[2],"conditions":[3,47],"in":[4,110],"an":[5],"enclosed":[6],"space":[7],"are":[8,66],"usually":[9],"controlled":[10],"to":[11,60,69,88,105,160,165],"ensure":[12],"the":[13,18,39,70,75,89,103,107,111,118,125,129,143,151,155,162],"health":[14],"comfort":[16,36],"of":[17,23,52,128,157],"occupants,":[19],"proper":[21],"functioning":[22],"sensitive":[24],"electronic":[25],"equipment":[26,71],"such":[27],"as":[28,35],"computers,":[29],"etc.":[30],"The":[31,46,146],"former":[32],"is":[33,41,82,169],"referred":[34],"conditioning":[37],"latter":[40],"called":[42],"process":[43,79],"air":[44],"conditioning.":[45],"required":[48,159],"for":[49,78],"optimum":[50],"operation":[51],"machinery":[53,81],"may":[54],"not":[55],"coincide":[56],"with":[57],"those":[58],"conductive":[59],"human":[61,91,94,130,152],"comfort.":[62,92],"Process":[63],"air-conditioning":[64],"requirements":[65],"highly":[67],"specific":[68],"or":[72,80],"operation.":[73],"Once":[74],"necessary":[76],"condition":[77],"established,":[83],"attention":[84],"must":[85],"be":[86,97],"paid":[87],"acceptable":[90],"Although":[93],"beings":[95,131,153],"can":[96],"considered":[98],"very":[99],"versatile":[100],"machines":[101],"having":[102],"capacity":[104],"adapt":[106],"wide":[108],"variations":[109],"working":[112,135],"environment,":[113,136],"their":[114,134],"productivity":[115],"depends":[116],"on":[117,133],"immediate":[119],"environment.":[120,145],"This":[121],"paper":[122],"discusses":[123],"about":[124],"CO2":[126],"generation":[127],"based":[132],"activity,":[137],"metabolism":[138],"its":[140],"effects":[141],"inside":[142],"indoor":[144,147],"pollutants":[148],"created":[149],"by":[150],"rate":[156],"ventilation":[158],"dilute":[161],"pollutant":[163],"levels":[164],"meet":[166],"ASHRAE":[167],"standards":[168],"also":[170],"discussed.":[171]},"counts_by_year":[],"updated_date":"2026-10-27T15:51:10.671819","created_date":"2017-07-21T00:00:00"}