{"id":"https://openalex.org/W2728062092","doi":"https://doi.org/10.1109/siu.2017.7960293","title":"Energy-aware access point selection for smartphones","display_name":"Energy-aware access point selection for smartphones","publication_year":2017,"publication_date":"2017-05-01","ids":{"openalex":"https://openalex.org/W2728062092","doi":"https://doi.org/10.1109/siu.2017.7960293","mag":"2728062092"},"language":"en","primary_location":{"id":"doi:10.1109/siu.2017.7960293","doi":"https://doi.org/10.1109/siu.2017.7960293","is_oa":false,"landing_page_url":"https://doi.org/10.1109/siu.2017.7960293","pdf_url":null,"source":{"id":"https://openalex.org/S4363607818","display_name":"Signal Processing and Communications Applications Conference (SIU)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 25th Signal Processing and Communications Applications Conference (SIU)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5008124723","display_name":"Mehmet Fatih T\u00fcys\u00fcz","orcid":"https://orcid.org/0000-0002-8955-9710","observed_orcids":["https://orcid.org/0000-0002-8955-9710"]},"institutions":[{"id":"https://openalex.org/I80538482","display_name":"Harran University","ror":"https://ror.org/057qfs197","country_code":"TR","type":"education","lineage":["https://openalex.org/I80538482"]}],"countries":["TR"],"is_corresponding":false,"raw_author_name":"Mehmet Fatih Tuysuz","raw_affiliation_strings":["Bilgisayar M\u00fchendisli\u011fi, Harran \u00dcniversitesi, \u015eanl\u0131urfa"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Bilgisayar M\u00fchendisli\u011fi, Harran \u00dcniversitesi, \u015eanl\u0131urfa","institution_ids":["https://openalex.org/I80538482"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5033716235","display_name":"Murat U\u00e7an","orcid":"https://orcid.org/0000-0001-9219-2262","observed_orcids":["https://orcid.org/0000-0001-9219-2262"]},"institutions":[{"id":"https://openalex.org/I80538482","display_name":"Harran University","ror":"https://ror.org/057qfs197","country_code":"TR","type":"education","lineage":["https://openalex.org/I80538482"]}],"countries":["TR"],"is_corresponding":false,"raw_author_name":"Murat Ucan","raw_affiliation_strings":["Bilgisayar M\u00fchendisli\u011fi, Harran \u00dcniversitesi, \u015eanl\u0131urfa"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Bilgisayar M\u00fchendisli\u011fi, Harran \u00dcniversitesi, \u015eanl\u0131urfa","institution_ids":["https://openalex.org/I80538482"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I80538482"],"apc_list":null,"apc_paid":null,"fwci":0.3874,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.41862651,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.836899995803833,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.836899995803833,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11158","display_name":"Wireless Networks and Protocols","score":0.133200004696846,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10651","display_name":"IPv6, Mobility, Handover, Networks, Security","score":0.018300000578165054,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/smartphones","display_name":"smartphones","score":0.5899999737739563},{"id":"https://openalex.org/keywords/wireless-network-interface-cards","display_name":"wireless network interface cards","score":0.9139999747276306},{"id":"https://openalex.org/keywords/energy-efficiency","display_name":"energy efficiency","score":0.5509999990463257},{"id":"https://openalex.org/keywords/android-application","display_name":"Android application","score":0.6940000057220459},{"id":"https://openalex.org/keywords/attachment-points","display_name":"point of attachment","score":0.8220000267028809},{"id":"https://openalex.org/keywords/channel-scanning","display_name":"channel scanning","score":0.7789999842643738},{"id":"https://openalex.org/keywords/switching-costs","display_name":"switching costs","score":0.7820000052452087},{"id":"https://openalex.org/keywords/battery-energy-consumption","display_name":"battery consumption","score":0.5709999799728394},{"id":"https://openalex.org/keywords/mobile-device-energy-consumption","display_name":"mobile device energy consumption","score":0.5180000066757202}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7456187605857849},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.6758356094360352},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.6651899218559265},{"id":"https://openalex.org/C557433098","wikidata":"https://www.wikidata.org/wiki/Q94","display_name":"Android (operating system)","level":2,"score":0.6034143567085266},{"id":"https://openalex.org/C186967261","wikidata":"https://www.wikidata.org/wiki/Q5082128","display_name":"Mobile device","level":2,"score":0.5807089805603027},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.5143012404441833},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.5121016502380371},{"id":"https://openalex.org/C103987645","wikidata":"https://www.wikidata.org/wiki/Q985806","display_name":"Network interface","level":3,"score":0.4402344822883606},{"id":"https://openalex.org/C62793504","wikidata":"https://www.wikidata.org/wiki/Q228327","display_name":"Access network","level":2,"score":0.4357547163963318},{"id":"https://openalex.org/C108037233","wikidata":"https://www.wikidata.org/wiki/Q11375","display_name":"Wireless network","level":3,"score":0.43162116408348083},{"id":"https://openalex.org/C153646914","wikidata":"https://www.wikidata.org/wiki/Q535695","display_name":"Cellular network","level":2,"score":0.42100682854652405},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.380041241645813},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.12518155574798584},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09175989031791687},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.08134663105010986},{"id":"https://openalex.org/C172173386","wikidata":"https://www.wikidata.org/wiki/Q79984","display_name":"Ethernet","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/siu.2017.7960293","doi":"https://doi.org/10.1109/siu.2017.7960293","is_oa":false,"landing_page_url":"https://doi.org/10.1109/siu.2017.7960293","pdf_url":null,"source":{"id":"https://openalex.org/S4363607818","display_name":"Signal Processing and Communications Applications Conference (SIU)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 25th Signal Processing and Communications Applications Conference (SIU)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.6773999929428101,"id":"https://metadata.un.org/sdg/9"},{"display_name":"Affordable and clean energy","score":0.5690000057220459,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W2109854378","https://openalex.org/W2122170512","https://openalex.org/W2133472473","https://openalex.org/W2167362795","https://openalex.org/W4234911159"],"related_works":["https://openalex.org/W2903404711","https://openalex.org/W2007728187","https://openalex.org/W2559636723","https://openalex.org/W1993829395","https://openalex.org/W2407840928","https://openalex.org/W3029215500","https://openalex.org/W4317209918","https://openalex.org/W1601550213","https://openalex.org/W3004008514","https://openalex.org/W2006541865"],"abstract_inverted_index":{"Wireless":[0,60],"networks":[1],"have":[2],"become":[3,39],"one":[4,40],"of":[5,41,75,79,101,115,134,144],"the":[6,14,42,50,80,97,108,116,121,142],"most":[7,43,98],"popular":[8],"network":[9],"access":[10,27],"technologies":[11,28],"today":[12],"with":[13],"mobility":[15],"they":[16],"provide":[17],"to":[18,49],"users.":[19],"However,":[20],"there":[21],"are":[22,30],"also":[23],"weaknesses":[24],"in":[25],"radio":[26],"that":[29,53,93],"becoming":[31],"increasingly":[32],"common.":[33],"For":[34],"example,":[35],"energy":[36,77,112,145],"efficiency":[37],"has":[38],"important":[44],"issues":[45],"for":[46,104],"users":[47],"due":[48],"limited":[51],"battery":[52],"mobile":[54,105],"devices":[55],"have.":[56],"In":[57,82,107],"this":[58,83],"context,":[59],"Network":[61],"Interface":[62],"Cards":[63],"(WNIC)":[64],"must":[65],"be":[66],"carefully":[67],"examined":[68],"as":[69],"it":[70],"constitutes":[71],"a":[72],"major":[73],"part":[74],"total":[76],"consumption":[78,113],"system.":[81],"work,":[84],"we":[85],"propose":[86],"an":[87],"android-based":[88],"energy-aware":[89],"network/interface":[90],"selection":[91],"application":[92],"detects":[94],"and":[95,141],"connects":[96],"proper":[99],"Point":[100],"Attachment":[102],"(PoA)":[103],"devices.":[106],"proposed":[109],"study,":[110],"estimated":[111],"amounts":[114],"device":[117],"were":[118],"calculated":[119],"using":[120],"channel":[122,127],"scanning":[123],"results,":[124],"switching":[125],"costs,":[126],"busy":[128],"times":[129],"(CBT),":[130],"traffic":[131],"classes,":[132],"number":[133],"stations":[135],"stored":[136],"at":[137],"each":[138,148],"connection":[139],"point,":[140],"amount":[143],"consumed":[146],"by":[147],"WNIC.":[149]},"counts_by_year":[{"year":2020,"cited_by_count":1}],"updated_date":"2026-10-05T09:50:58.205359","created_date":"2017-07-14T00:00:00"}
