{"id":"https://openalex.org/W269949159","doi":null,"title":"AUTOMATIC LOADING TRANSFER CONTROL TECHNOLOGY TO ELIMINATE OVERLOAD","display_name":"AUTOMATIC LOADING TRANSFER CONTROL TECHNOLOGY TO ELIMINATE OVERLOAD","publication_year":2014,"publication_date":"2014-08-01","ids":{"openalex":"https://openalex.org/W269949159","mag":"269949159"},"language":"en","primary_location":{"id":"mag:269949159","doi":null,"is_oa":false,"landing_page_url":"https://www.researchgate.net/profile/Chengyou_Wang/publication/265021038_Automatic_loading_transfer_control_technology_to_eliminate_overload/links/53fc71250cf22f21c2f3d8a0.pdf?disableCoverPage=true","pdf_url":null,"source":{"id":"https://openalex.org/S2913458251","display_name":"ICIC express letters. Part B, Applications","issn_l":"2185-2766","issn":["2185-2766"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","norway-1","poland-20","russia-white-list-4"],"host_organization":"https://openalex.org/P4366065265","host_organization_name":"ICIC International","host_organization_lineage":["https://openalex.org/P4366065265"],"host_organization_lineage_names":["ICIC International"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"ICIC express letters. Part B, Applications","raw_type":null},"volume":null,"type":"article","indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101496775","display_name":"Haizhen Wang","orcid":"https://orcid.org/0000-0003-3477-8673","observed_orcids":["https://orcid.org/0000-0003-3477-8673"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Haizhen Wang","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0003-3477-8673","affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5075452196","display_name":"Baochen Jiang","orcid":"https://orcid.org/0000-0002-6055-2355","observed_orcids":["https://orcid.org/0000-0002-6055-2355"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Baochen Jiang","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0002-6055-2355","affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5015144801","display_name":"Chengyou Wang","orcid":"https://orcid.org/0000-0002-0901-2492","observed_orcids":["https://orcid.org/0000-0002-0901-2492"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Chengyou Wang","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0002-0901-2492","affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.01269608,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"5","issue":"4","first_page":"989","last_page":"994"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.6401000022888184,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.6401000022888184,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.2020999938249588,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.0860000029206276,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/backup-power-supply","display_name":"emergency power supply","score":0.8519999980926514},{"id":"https://openalex.org/keywords/power-system-operation-modes","display_name":"power system operating modes","score":0.7049999833106995},{"id":"https://openalex.org/keywords/load-transfer","display_name":"load transfer","score":0.3889999985694885}],"concepts":[{"id":"https://openalex.org/C2780945871","wikidata":"https://www.wikidata.org/wiki/Q194274","display_name":"Backup","level":2,"score":0.9235663414001465},{"id":"https://openalex.org/C192690417","wikidata":"https://www.wikidata.org/wiki/Q1030817","display_name":"Busbar","level":2,"score":0.8694227933883667},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6481221318244934},{"id":"https://openalex.org/C2776175482","wikidata":"https://www.wikidata.org/wiki/Q1195816","display_name":"Transfer (computing)","level":2,"score":0.6150738596916199},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5564789175987244},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5141544938087463},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.46376466751098633},{"id":"https://openalex.org/C48677424","wikidata":"https://www.wikidata.org/wiki/Q6888088","display_name":"Mode (computer interface)","level":2,"score":0.43982934951782227},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.426433801651001},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2790348529815674},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.20288050174713135},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.09818977117538452},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.07758042216300964},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:269949159","doi":null,"is_oa":false,"landing_page_url":"https://www.researchgate.net/profile/Chengyou_Wang/publication/265021038_Automatic_loading_transfer_control_technology_to_eliminate_overload/links/53fc71250cf22f21c2f3d8a0.pdf?disableCoverPage=true","pdf_url":null,"source":{"id":"https://openalex.org/S2913458251","display_name":"ICIC express letters. Part B, Applications","issn_l":"2185-2766","issn":["2185-2766"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","norway-1","poland-20","russia-white-list-4"],"host_organization":"https://openalex.org/P4366065265","host_organization_name":"ICIC International","host_organization_lineage":["https://openalex.org/P4366065265"],"host_organization_lineage_names":["ICIC International"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"ICIC express letters. Part B, Applications","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"},{"score":0.5690000057220459,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1973309971","https://openalex.org/W2163232949","https://openalex.org/W2350880654","https://openalex.org/W2366109544","https://openalex.org/W2379547573","https://openalex.org/W2394057588"],"related_works":["https://openalex.org/W2388516373","https://openalex.org/W2349976551","https://openalex.org/W2352083457","https://openalex.org/W1752890782","https://openalex.org/W2905190817","https://openalex.org/W1627724414","https://openalex.org/W2558697981","https://openalex.org/W2365167643","https://openalex.org/W2376219045","https://openalex.org/W2166215298"],"abstract_inverted_index":{"The":[0,129],"conventional":[1],"methods":[2],"of":[3,23,57,59,75,103],"eliminating":[4],"the":[5,37,51,63,73,76,83,110,120],"overload":[6,64],"are":[7,19,114],"generally":[8],"based":[9],"on":[10],"algorithms":[11],"to":[12,45,61,68,72],"search":[13,94],"for":[14,95],"load":[15],"transfer":[16,40,144],"paths,":[17],"which":[18,91],"a":[20,86],"large":[21],"amount":[22],"calculation":[24],"and":[25,49,80,118,138],"low":[26],"feasibility.":[27],"When":[28,106],"accidents":[29],"or":[30],"device":[31],"faults":[32],"occur":[33],"in":[34,98],"power":[35,47,77,104],"grid,":[36],"busbar":[38,142],"automatic":[39,143],"switch":[41,145],"(BATS)":[42],"is":[43,108,123,136],"used":[44],"backup":[46,69],"supply,":[48],"ensure":[50],"continuity.":[52],"This":[53],"paper":[54,84],"makes":[55],"use":[56],"thoughts":[58],"BATS":[60,88,96,112],"eliminate":[62],"by":[65],"transferring":[66],"it":[67],"power.":[70],"Due":[71],"complexity":[74],"grid":[78],"structure":[79],"operation":[81,101],"mode,":[82],"proposed":[85],"new":[87],"auto-generated":[89],"algorithm,":[90],"can":[92],"automatically":[93,115],"models":[97,113],"accordance":[99],"with":[100],"modes":[102],"system.":[105],"there":[107],"overload,":[109],"corresponding":[111],"found":[116],"out,":[117],"then":[119],"feasible":[121,137],"plan":[122],"generated":[124],"through":[125],"control":[126,152],"technology":[127,153],"automatically.":[128],"practical":[130],"analysis":[131],"proves":[132],"that":[133],"this":[134],"method":[135],"practical.":[139],"Keywords:":[140],"Intelligent":[141],"(BATS),":[146],"Overload":[147],"eliminating,":[148],"Auto-adapted":[149],"modeling,":[150],"Transfer":[151]},"counts_by_year":[],"updated_date":"2025-10-10T17:16:08.811792","created_date":"2016-06-24T00:00:00"}
