{"id":"https://openalex.org/W2622334648","doi":null,"title":"Passive Cooling of buildings by night-time ventilation","display_name":"Passive Cooling of buildings by night-time ventilation","publication_year":2008,"publication_date":"2008-01-01","ids":{"openalex":"https://openalex.org/W2622334648","mag":"2622334648"},"language":"en","primary_location":{"id":"pmh:oai:pure.atira.dk:openaire/63a4a210-e7ba-11dd-b0a4-000ea68e967b","doi":null,"is_oa":true,"landing_page_url":"https://vbn.aau.dk/da/publications/63a4a210-e7ba-11dd-b0a4-000ea68e967b","pdf_url":null,"source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Artmann, N, Manz, H & Heiselberg, P 2008, Passive Cooling of buildings by night-time ventilation. Schlussbericht. Eidgen\u00f6ssisches Departement f\u00fcr Umwelt, Verkehr, Energie und Kommunikation, UVEK. Bundesamt f\u00fcr Energie BFE, Duebendorf.","raw_type":"book"},"volume":null,"type":"book","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://vbn.aau.dk/da/publications/63a4a210-e7ba-11dd-b0a4-000ea68e967b","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5057412777","display_name":"Nikolai Artmann","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Nikolai Artmann","raw_affiliation_strings":["Department of Civil Engineering"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Civil Engineering","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043851680","display_name":"Heinrich Manz","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Heinrich Manz","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5027966910","display_name":"Per Heiselberg","orcid":"https://orcid.org/0000-0002-1600-9603","observed_orcids":["https://orcid.org/0000-0002-1600-9603"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Per Heiselberg","raw_affiliation_strings":["Division of Architectural Engineering"],"raw_orcid":"https://orcid.org/0000-0002-1600-9603","affiliations":[{"raw_affiliation_string":"Division of Architectural Engineering","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.5695,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.74248927,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13298","display_name":"Solar Energy Systems and Technologies","score":0.0012000000569969416,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11371","display_name":"Wind and Air Flow Studies","score":0.0007999999797903001,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/passive-cooling","display_name":"passive cooling","score":0.9319999814033508},{"id":"https://openalex.org/keywords/night-ventilation","display_name":"night ventilation","score":0.9950000047683716},{"id":"https://openalex.org/keywords/building-cooling-energy-demand","display_name":"building cooling energy demand","score":0.8059999942779541},{"id":"https://openalex.org/keywords/global-warming","display_name":"global warming","score":0.7300000190734863},{"id":"https://openalex.org/keywords/thermal-comfort","display_name":"thermal comfort","score":0.6850000023841858},{"id":"https://openalex.org/keywords/heat-transfer-coefficient","display_name":"heat transfer coefficient","score":0.6940000057220459},{"id":"https://openalex.org/keywords/mixed-ventilation","display_name":"mixing ventilation","score":0.7940000295639038},{"id":"https://openalex.org/keywords/displacement-ventilation","display_name":"displacement ventilation","score":0.9990000128746033},{"id":"https://openalex.org/keywords/temperature-efficiency","display_name":"temperature efficiency","score":0.8320000171661377}],"concepts":[{"id":"https://openalex.org/C2776668771","wikidata":"https://www.wikidata.org/wiki/Q5282619","display_name":"Displacement ventilation","level":3,"score":0.8417649865150452},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.7849934101104736},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.6553767323493958},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.5889570116996765},{"id":"https://openalex.org/C79795727","wikidata":"https://www.wikidata.org/wiki/Q3068508","display_name":"Passive cooling","level":3,"score":0.5425503849983215},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.4758598208427429},{"id":"https://openalex.org/C206018219","wikidata":"https://www.wikidata.org/wiki/Q1427418","display_name":"Natural ventilation","level":3,"score":0.467494398355484},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.45759448409080505},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.3896395266056061},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.18975836038589478},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07002639770507812}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:pure.atira.dk:openaire/63a4a210-e7ba-11dd-b0a4-000ea68e967b","doi":null,"is_oa":true,"landing_page_url":"https://vbn.aau.dk/da/publications/63a4a210-e7ba-11dd-b0a4-000ea68e967b","pdf_url":null,"source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Artmann, N, Manz, H & Heiselberg, P 2008, Passive Cooling of buildings by night-time ventilation. Schlussbericht. Eidgen\u00f6ssisches Departement f\u00fcr Umwelt, Verkehr, Energie und Kommunikation, UVEK. Bundesamt f\u00fcr Energie BFE, Duebendorf.","raw_type":"book"},{"id":"mag:2622334648","doi":null,"is_oa":false,"landing_page_url":"https://vbn.aau.dk/en/publications/passive-cooling-of-buildings-by-night-time-ventilation","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":{"id":"pmh:oai:pure.atira.dk:openaire/63a4a210-e7ba-11dd-b0a4-000ea68e967b","doi":null,"is_oa":true,"landing_page_url":"https://vbn.aau.dk/da/publications/63a4a210-e7ba-11dd-b0a4-000ea68e967b","pdf_url":null,"source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Artmann, N, Manz, H & Heiselberg, P 2008, Passive Cooling of buildings by night-time ventilation. Schlussbericht. Eidgen\u00f6ssisches Departement f\u00fcr Umwelt, Verkehr, Energie und Kommunikation, UVEK. Bundesamt f\u00fcr Energie BFE, Duebendorf.","raw_type":"book"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.75,"id":"https://metadata.un.org/sdg/7"},{"display_name":"Climate action","score":0.685699999332428,"id":"https://metadata.un.org/sdg/13"},{"display_name":"Sustainable cities and communities","score":0.46639999747276306,"id":"https://metadata.un.org/sdg/11"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":52,"referenced_works":["https://openalex.org/W13429210","https://openalex.org/W33437351","https://openalex.org/W569686623","https://openalex.org/W1522296012","https://openalex.org/W1572686265","https://openalex.org/W1583276246","https://openalex.org/W1585676722","https://openalex.org/W1889188928","https://openalex.org/W1970248112","https://openalex.org/W1970778642","https://openalex.org/W1971598020","https://openalex.org/W1975593688","https://openalex.org/W1981087678","https://openalex.org/W1991591152","https://openalex.org/W1994960483","https://openalex.org/W1995007374","https://openalex.org/W1999228850","https://openalex.org/W2002729176","https://openalex.org/W2008668438","https://openalex.org/W2012417829","https://openalex.org/W2013008076","https://openalex.org/W2030322991","https://openalex.org/W2036743380","https://openalex.org/W2040190334","https://openalex.org/W2060435696","https://openalex.org/W2068381304","https://openalex.org/W2070451639","https://openalex.org/W2074787411","https://openalex.org/W2079208323","https://openalex.org/W2080473702","https://openalex.org/W2087066715","https://openalex.org/W2094448756","https://openalex.org/W2097075313","https://openalex.org/W2113250831","https://openalex.org/W2149478966","https://openalex.org/W2156119751","https://openalex.org/W2162392623","https://openalex.org/W2169654981","https://openalex.org/W2185402298","https://openalex.org/W2187406533","https://openalex.org/W2272620222","https://openalex.org/W2299498014","https://openalex.org/W2493745797","https://openalex.org/W2503332585","https://openalex.org/W2504428220","https://openalex.org/W2507053384","https://openalex.org/W2596847770","https://openalex.org/W2610077930","https://openalex.org/W2737476851","https://openalex.org/W2980797340","https://openalex.org/W3033219100","https://openalex.org/W3040293015"],"related_works":["https://openalex.org/W7095975804","https://openalex.org/W1970778642","https://openalex.org/W2097075313","https://openalex.org/W2607272578","https://openalex.org/W596331648","https://openalex.org/W2080473702","https://openalex.org/W7052007720","https://openalex.org/W6946030513","https://openalex.org/W2014243306","https://openalex.org/W7008905617"],"abstract_inverted_index":{"Due":[0],"to":[1,47],"an":[2,6,188],"overall":[3],"trend":[4],"towards":[5],"increasing":[7],"cooling":[8,23,50,67,99,124,183],"energy":[9,102],"demand":[10],"in":[11,13,37,95,142,151],"buildings":[12],"many":[14],"European":[15],"countries":[16],"over":[17],"the":[18,65,72,106,115,123,161,163,167,173,180],"last":[19],"few":[20],"decades,":[21],"passive":[22,49],"by":[24,114,184],"night-time":[25,53,91,109,140,185],"ventilation":[26,54,92,110,141,148,168,186],"is":[27,55,93,111,126],"seen":[28],"as":[29,122],"a":[30,61,80,152,176],"promising":[31],"concept.":[32],"However,":[33],"because":[34],"of":[35,74,108,144,166,191],"uncertainties":[36],"thermal":[38],"comfort":[39],"predictions,":[40],"architects":[41],"and":[42,71,146],"engineers":[43],"are":[44],"still":[45],"hesitant":[46],"apply":[48],"techniques.":[51],"As":[52],"highly":[56],"dependent":[57],"on":[58,172],"climatic":[59,66],"conditions,":[60],"method":[62,177],"for":[63,129,178,182],"quantifying":[64],"potential":[68,86,181],"was":[69,77,83,149,169,193],"developed":[70],"impact":[73],"climate":[75],"warming":[76],"investigated.":[78],"Although":[79],"clear":[81],"decrease":[82],"found,":[84],"significant":[85],"will":[87],"remain,":[88],"especially":[89],"if":[90],"applied":[94],"combination":[96],"with":[97],"other":[98],"methods.":[100],"Building":[101],"simulations":[103],"showed":[104],"that":[105],"performance":[107],"also":[112],"affected":[113],"heat":[116,130],"transfer":[117,131,138],"at":[118,157],"internal":[119],"room":[120,156],"surfaces,":[121],"effect":[125],"very":[127],"limited":[128],"coefficients":[132],"below":[133],"about":[134],"4":[135],"W/m2K.":[136],"Heat":[137],"during":[139,187],"case":[143],"mixing":[145],"displacement":[147],"investigated":[150],"full":[153],"scale":[154],"test":[155],"Aalborg":[158],"University.":[159],"In":[160],"experiments":[162],"temperature":[164],"efficiency":[165],"determined.":[170],"Based":[171],"previous":[174],"re-sults":[175],"estimating":[179],"early":[189],"stage":[190],"design":[192],"developed.":[194]},"counts_by_year":[{"year":2018,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2017-06-15T00:00:00"}
