{"id":"https://openalex.org/W2594319271","doi":"https://doi.org/10.1109/tia.2017.2679679","title":"Solid-State-Transformer-Interfaced Permanent Magnet Wind Turbine Distributed Generation System With Power Management Functions","display_name":"Solid-State-Transformer-Interfaced Permanent Magnet Wind Turbine Distributed Generation System With Power Management Functions","alternate_titles":[],"publication_year":2017,"publication_date":"2017-03-08","ids":{"openalex":"https://openalex.org/W2594319271","doi":"https://doi.org/10.1109/tia.2017.2679679","mag":"2594319271"},"language":"en","primary_location":{"id":"doi:10.1109/tia.2017.2679679","doi":"https://doi.org/10.1109/tia.2017.2679679","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tia.2017.2679679","pdf_url":null,"source":{"id":"https://openalex.org/S192268925","display_name":"IEEE Transactions on Industry Applications","issn_l":"0093-9994","issn":["0093-9994","1939-9367"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industry Applications","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2594319271"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100775761","display_name":"Rui Gao","orcid":"https://orcid.org/0000-0003-3711-1866","observed_orcids":["https://orcid.org/0000-0003-3711-1866"]},"institutions":[{"id":"https://openalex.org/I137902535","display_name":"North Carolina State University","ror":"https://ror.org/04tj63d06","country_code":"US","type":"education","lineage":["https://openalex.org/I137902535"]}],"countries":["US"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Rui Gao","raw_affiliation_strings":["Future Renewable Electric Energy Delivery and Management (FREEDM) Systems Center, North Carolina State University, Raleigh, NC, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Future Renewable Electric Energy Delivery and Management (FREEDM) Systems Center, North Carolina State University, Raleigh, NC, USA","institution_ids":["https://openalex.org/I137902535"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082583323","display_name":"Xu She","orcid":"https://orcid.org/0000-0002-2567-7179","observed_orcids":["https://orcid.org/0000-0002-2567-7179"]},"institutions":[{"id":"https://openalex.org/I4210134512","display_name":"GE Global Research (United States)","ror":"https://ror.org/03e06qt98","country_code":"US","type":"company","lineage":["https://openalex.org/I4210134512"]}],"countries":["US"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Xu She","raw_affiliation_strings":["GE Global Research, Niskayuna, NY, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"GE Global Research, Niskayuna, NY, USA","institution_ids":["https://openalex.org/I4210134512"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5027386627","display_name":"Iqbal Husain","orcid":"https://orcid.org/0000-0003-0089-4326","observed_orcids":["https://orcid.org/0000-0003-0089-4326"]},"institutions":[{"id":"https://openalex.org/I137902535","display_name":"North Carolina State University","ror":"https://ror.org/04tj63d06","country_code":"US","type":"education","lineage":["https://openalex.org/I137902535"]}],"countries":["US"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Iqbal Husain","raw_affiliation_strings":["Future Renewable Electric Energy Delivery and Management (FREEDM) Systems Center, North Carolina State University, Raleigh, NC, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Future Renewable Electric Energy Delivery and Management (FREEDM) Systems Center, North Carolina State University, Raleigh, NC, USA","institution_ids":["https://openalex.org/I137902535"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5011191579","display_name":"Alex Qin Huang","orcid":"https://orcid.org/0000-0003-3427-0335","observed_orcids":["https://orcid.org/0000-0003-3427-0335"]},"institutions":[{"id":"https://openalex.org/I137902535","display_name":"North Carolina State University","ror":"https://ror.org/04tj63d06","country_code":"US","type":"education","lineage":["https://openalex.org/I137902535"]}],"countries":["US"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Alex Q. Huang","raw_affiliation_strings":["Future Renewable Electric Energy Delivery and Management (FREEDM) Systems Center, North Carolina State University, Raleigh, NC, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Future Renewable Electric Energy Delivery and Management (FREEDM) Systems Center, North Carolina State University, Raleigh, NC, USA","institution_ids":["https://openalex.org/I137902535"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":4.0636,"has_fulltext":false,"cited_by_count":84,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.94726493,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":96,"max":99},"biblio":{"volume":"53","issue":"4","first_page":"3849","last_page":"3861"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9282000064849854,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9282000064849854,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.0478999987244606,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.006000000052154064,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/solid-state-transformer","display_name":"solid-state transformer","score":0.9940000176429749},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"permanent magnet synchronous generator","score":0.9869999885559082},{"id":"https://openalex.org/keywords/wind-energy-conversion-system","display_name":"wind energy conversion system","score":0.9259999990463257},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"distributed generation","score":0.8960000276565552},{"id":"https://openalex.org/keywords/power-management","display_name":"power management","score":0.765999972820282},{"id":"https://openalex.org/keywords/reactive-power-compensation","display_name":"reactive power compensation","score":0.9409999847412109},{"id":"https://openalex.org/keywords/active-power-management","display_name":"active power management","score":0.7160000205039978},{"id":"https://openalex.org/keywords/dc-grid","display_name":"DC grid","score":0.5199999809265137},{"id":"https://openalex.org/keywords/islanded-operation","display_name":"islanded operation","score":0.7279999852180481},{"id":"https://openalex.org/keywords/grid-connected-operation","display_name":"grid-connected operation","score":0.7730000019073486},{"id":"https://openalex.org/keywords/mode-switching","display_name":"mode switching","score":0.7689999938011169},{"id":"https://openalex.org/keywords/medium-voltage-power-electronics","display_name":"medium-voltage power electronics","score":0.42899999022483826}],"concepts":[{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.731293261051178},{"id":"https://openalex.org/C2778675665","wikidata":"https://www.wikidata.org/wiki/Q1308552","display_name":"Islanding","level":4,"score":0.7086982727050781},{"id":"https://openalex.org/C201320609","wikidata":"https://www.wikidata.org/wiki/Q3274420","display_name":"Permanent magnet synchronous generator","level":3,"score":0.6385560035705566},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.5203944444656372},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5170543789863586},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.5168048143386841},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.5121662616729736},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4819181263446808},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.47889915108680725},{"id":"https://openalex.org/C145180747","wikidata":"https://www.wikidata.org/wiki/Q7236587","display_name":"Power optimizer","level":5,"score":0.44861143827438354},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.39152294397354126},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3544175624847412},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3455621600151062},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.26033860445022583},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.22743535041809082},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.13012158870697021},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tia.2017.2679679","doi":"https://doi.org/10.1109/tia.2017.2679679","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tia.2017.2679679","pdf_url":null,"source":{"id":"https://openalex.org/S192268925","display_name":"IEEE Transactions on Industry Applications","issn_l":"0093-9994","issn":["0093-9994","1939-9367"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industry Applications","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":1.0,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/9","score":0.8970999717712402,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[{"id":"https://openalex.org/G4562851031","display_name":null,"funder_award_id":"EEC-0812121","funder_id":"https://openalex.org/F4320337394","funder_display_name":"Division of Engineering Education and Centers"}],"funders":[{"id":"https://openalex.org/F4320337394","display_name":"Division of Engineering Education and Centers","ror":"https://ror.org/050rnw378"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":33,"referenced_works":["https://openalex.org/W1529693510","https://openalex.org/W1585835307","https://openalex.org/W1605124517","https://openalex.org/W1966751624","https://openalex.org/W1969412223","https://openalex.org/W1991562391","https://openalex.org/W1999302015","https://openalex.org/W2000794749","https://openalex.org/W2002522387","https://openalex.org/W2050398607","https://openalex.org/W2056943204","https://openalex.org/W2060472803","https://openalex.org/W2073630849","https://openalex.org/W2094655209","https://openalex.org/W2102406524","https://openalex.org/W2105269061","https://openalex.org/W2105303942","https://openalex.org/W2109916442","https://openalex.org/W2118203870","https://openalex.org/W2121230363","https://openalex.org/W2129916306","https://openalex.org/W2132755931","https://openalex.org/W2136700375","https://openalex.org/W2140356380","https://openalex.org/W2157176524","https://openalex.org/W2162448500","https://openalex.org/W2210339003","https://openalex.org/W2328119608","https://openalex.org/W2334652519","https://openalex.org/W2404311271","https://openalex.org/W2487730025","https://openalex.org/W2588967373","https://openalex.org/W4206097780"],"related_works":["https://openalex.org/W2810651665","https://openalex.org/W2404311271","https://openalex.org/W1605124517","https://openalex.org/W1979766874","https://openalex.org/W2613948902","https://openalex.org/W2000794749","https://openalex.org/W4210792070","https://openalex.org/W4240812950","https://openalex.org/W4405384136","https://openalex.org/W2526304005"],"abstract_inverted_index":{"The":[0],"higher":[1],"penetration":[2],"of":[3,16,50,114],"wind":[4,18,51,74],"energy":[5,19,88],"poses":[6],"increasing":[7],"demand":[8],"for":[9,68,87],"grid":[10],"support":[11],"and":[12,41,54,102],"power":[13,39,43,63],"management":[14,40,64],"functions":[15],"a":[17,26,47,61,69,80,125],"conversion":[20],"system":[21,35],"(WECS).":[22],"This":[23],"paper":[24],"investigates":[25],"medium-voltage":[27],"solid-state":[28],"transformer":[29],"(SST)-interfaced":[30],"permanent":[31],"magnet":[32],"synchronous":[33],"generator":[34],"with":[36,72],"integrated":[37],"active":[38],"reactive":[42],"compensation":[44],"functions.":[45],"Specifically,":[46],"WECS":[48],"consisting":[49],"turbines,":[52],"SSTs,":[53],"dc":[55,70],"loads":[56],"is":[57,66,121],"presented.":[58],"In":[59],"addition,":[60],"distributed":[62],"algorithm":[65],"proposed":[67,116],"network":[71],"local":[73],"turbine":[75],"controls":[76],"incorporated":[77],"to":[78,110],"achieve":[79],"self-contained":[81],"power-balanced":[82],"condition":[83],"without":[84],"the":[85,96,99,103,112,115,119],"need":[86],"storage":[89],"or":[90],"communication":[91],"devices.":[92],"Scenarios":[93],"considered":[94],"include":[95],"grid-connected":[97],"mode,":[98,101],"islanding":[100],"mode":[104],"transitions.":[105],"Simulation":[106],"results":[107],"are":[108],"provided":[109],"verify":[111],"effectiveness":[113],"strategy.":[117],"Additionally,":[118],"concept":[120],"experimentally":[122],"verified":[123],"using":[124],"scaled-down":[126],"laboratory":[127],"prototype.":[128]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2594319271","counts_by_year":[{"year":2026,"cited_by_count":5},{"year":2025,"cited_by_count":8},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":9},{"year":2021,"cited_by_count":10},{"year":2020,"cited_by_count":12},{"year":2019,"cited_by_count":12},{"year":2018,"cited_by_count":15},{"year":2017,"cited_by_count":4}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2017-03-16T00:00:00"}
