{"id":"https://openalex.org/W2588035263","doi":null,"title":"Low GWP Refrigerants for Air Conditioning and Chiller Applications","display_name":"Low GWP Refrigerants for Air Conditioning and Chiller Applications","publication_year":2016,"publication_date":"2016-07-11","ids":{"openalex":"https://openalex.org/W2588035263","mag":"2588035263"},"language":"en","primary_location":{"id":"pmh:oai:docs.lib.purdue.edu:iracc-2820","doi":null,"is_oa":true,"landing_page_url":"https://docs.lib.purdue.edu/iracc/1821","pdf_url":"https://docs.lib.purdue.edu/iracc/1821","source":{"id":"https://openalex.org/S4377196310","display_name":"Purdue e-Pubs (Purdue University System)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801333002","host_organization_name":"Purdue University System","host_organization_lineage":["https://openalex.org/I2801333002"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Refrigeration and Air Conditioning Conference","raw_type":"text"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://docs.lib.purdue.edu/iracc/1821","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5064799089","display_name":"Ankit Sethi","orcid":"https://orcid.org/0000-0002-6907-7642","observed_orcids":["https://orcid.org/0000-0002-6907-7642"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ankit Sethi","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0002-6907-7642","affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5061183304","display_name":"Samuel Yana Motta","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"S F Yana-Motta","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.4953,"has_fulltext":true,"cited_by_count":9,"citation_normalized_percentile":{"value":0.85163545,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":96},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10402","display_name":"Phase Equilibria and Thermodynamics","score":0.0,"subfield":{"id":"https://openalex.org/subfields/1606","display_name":"Physical and Theoretical Chemistry"},"field":{"id":"https://openalex.org/fields/16","display_name":"Chemistry"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/low-gwp-refrigerants","display_name":"low-GWP refrigerants","score":0.9729999899864197},{"id":"https://openalex.org/keywords/r134a-replacement","display_name":"R134a replacement","score":0.8460000157356262},{"id":"https://openalex.org/keywords/residential-air-conditioning","display_name":"residential air conditioning","score":0.7910000085830688},{"id":"https://openalex.org/keywords/non-flammable-refrigerants","display_name":"non-flammable refrigerants","score":0.8460000157356262},{"id":"https://openalex.org/keywords/ambient-temperature-effects","display_name":"ambient temperature effects","score":0.7639999985694885},{"id":"https://openalex.org/keywords/system-simulation","display_name":"system simulation","score":0.6800000071525574}],"concepts":[{"id":"https://openalex.org/C4638862","wikidata":"https://www.wikidata.org/wiki/Q1501558","display_name":"Chiller","level":2,"score":0.9508816599845886},{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.9365215301513672},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.8250941038131714},{"id":"https://openalex.org/C182254935","wikidata":"https://www.wikidata.org/wiki/Q1722733","display_name":"Water chiller","level":4,"score":0.7723408937454224},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5589835047721863},{"id":"https://openalex.org/C164915370","wikidata":"https://www.wikidata.org/wiki/Q5167494","display_name":"Cooling capacity","level":2,"score":0.4594356417655945},{"id":"https://openalex.org/C2776461528","wikidata":"https://www.wikidata.org/wiki/Q131313","display_name":"Heat pump","level":3,"score":0.43515947461128235},{"id":"https://openalex.org/C24463637","wikidata":"https://www.wikidata.org/wiki/Q5099037","display_name":"Chiller boiler system","level":5,"score":0.42562389373779297},{"id":"https://openalex.org/C119288801","wikidata":"https://www.wikidata.org/wiki/Q901028","display_name":"Global-warming potential","level":3,"score":0.41751915216445923},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.40271759033203125},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.3581463098526001},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.20147067308425903},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.16843494772911072},{"id":"https://openalex.org/C47737302","wikidata":"https://www.wikidata.org/wiki/Q167336","display_name":"Greenhouse gas","level":2,"score":0.1611213982105255},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:docs.lib.purdue.edu:iracc-2820","doi":null,"is_oa":true,"landing_page_url":"https://docs.lib.purdue.edu/iracc/1821","pdf_url":"https://docs.lib.purdue.edu/iracc/1821","source":{"id":"https://openalex.org/S4377196310","display_name":"Purdue e-Pubs (Purdue University System)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801333002","host_organization_name":"Purdue University System","host_organization_lineage":["https://openalex.org/I2801333002"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Refrigeration and Air Conditioning Conference","raw_type":"text"},{"id":"mag:2588035263","doi":null,"is_oa":false,"landing_page_url":"https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=2820&context=iracc","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.","raw_type":null}],"best_oa_location":{"id":"pmh:oai:docs.lib.purdue.edu:iracc-2820","doi":null,"is_oa":true,"landing_page_url":"https://docs.lib.purdue.edu/iracc/1821","pdf_url":"https://docs.lib.purdue.edu/iracc/1821","source":{"id":"https://openalex.org/S4377196310","display_name":"Purdue e-Pubs (Purdue University System)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801333002","host_organization_name":"Purdue University System","host_organization_lineage":["https://openalex.org/I2801333002"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Refrigeration and Air Conditioning Conference","raw_type":"text"},"sustainable_development_goals":[{"score":0.685699999332428,"display_name":"Climate action","id":"https://metadata.un.org/sdg/13"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2588035263.pdf","grobid_xml":"https://content.openalex.org/works/W2588035263.grobid-xml"},"referenced_works_count":1,"referenced_works":["https://openalex.org/W2022113777"],"related_works":["https://openalex.org/W7067494801","https://openalex.org/W3035046477","https://openalex.org/W6906705656","https://openalex.org/W2587162692","https://openalex.org/W4298262868","https://openalex.org/W3034344648","https://openalex.org/W87253744","https://openalex.org/W3026169106","https://openalex.org/W4408310197","https://openalex.org/W3030041627"],"abstract_inverted_index":{"Refrigerants":[0],"with":[1],"low":[2,21],"environmental":[3],"impact":[4],"have":[5,27],"been":[6,28],"developed":[7],"as":[8],"replacements":[9,41],"for":[10,42,51,58],"R410A":[11,32,52],"in":[12,30,74],"stationary":[13],"air":[14],"conditioning":[15],"applications.":[16],"Non-flammable":[17],"and":[18,53,61],"mildly":[19],"flammable":[20],"global":[22],"warming":[23],"potential":[24],"(GWP)":[25],"refrigerants,":[26],"evaluated":[29],"representative":[31],"residential":[33],"equipment.":[34],"This":[35],"study":[36],"discusses":[37],"the":[38,77],"performance":[39],"these":[40,81],"ambient":[43],"temperatures":[44],"ranging":[45],"from":[46,69],"28oC":[47],"to":[48],"46oC.":[49],"Replacements":[50],"R134a":[54],"are":[55,72],"also":[56],"discussed":[57,73],"high":[59],"pressure":[60,63],"medium":[62],"chiller":[64],"applications":[65],"respectively.":[66],"Results":[67],"obtained":[68],"system":[70],"simulation":[71],"detail":[75],"showing":[76],"benefits":[78],"of":[79],"using":[80],"new":[82],"fluids.":[83]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1}],"updated_date":"2026-10-12T09:40:04.860316","created_date":"2017-02-24T00:00:00"}