{"id":"https://openalex.org/W2586151007","doi":"https://doi.org/10.1080/23744731.2017.1285174","title":"Cooling performance test and analysis of a radiant\u2013convective air-conditioning terminal device with parallel pipes","display_name":"Cooling performance test and analysis of a radiant\u2013convective air-conditioning terminal device with parallel pipes","publication_year":2017,"publication_date":"2017-02-10","ids":{"openalex":"https://openalex.org/W2586151007","doi":"https://doi.org/10.1080/23744731.2017.1285174","mag":"2586151007"},"language":"en","primary_location":{"id":"doi:10.1080/23744731.2017.1285174","doi":"https://doi.org/10.1080/23744731.2017.1285174","is_oa":false,"landing_page_url":"https://doi.org/10.1080/23744731.2017.1285174","pdf_url":null,"source":{"id":"https://openalex.org/S2764534234","display_name":"Science and Technology for the Built Environment","issn_l":"1078-9669","issn":["1078-9669","1938-5587","2374-4731","2374-474X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Science and Technology for the Built Environment","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Shu Haiwen","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I27357992","display_name":"Dalian University of Technology","ror":"https://ror.org/023hj5876","country_code":"CN","type":"education","lineage":["https://openalex.org/I27357992"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Shu Haiwen","raw_affiliation_strings":["School of Civil Engineering, Dalian University of Technology, Ganjingzi District, Dalian Liaoning Province 116024, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Civil Engineering, Dalian University of Technology, Ganjingzi District, Dalian Liaoning Province 116024, China","institution_ids":["https://openalex.org/I27357992"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001918550","display_name":"Wang Tingyu","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I27357992","display_name":"Dalian University of Technology","ror":"https://ror.org/023hj5876","country_code":"CN","type":"education","lineage":["https://openalex.org/I27357992"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wang Tingyu","raw_affiliation_strings":["School of Civil Engineering, Dalian University of Technology, Ganjingzi District, Dalian Liaoning Province 116024, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Civil Engineering, Dalian University of Technology, Ganjingzi District, Dalian Liaoning Province 116024, China","institution_ids":["https://openalex.org/I27357992"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111337679","display_name":"Shi Jing","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I27357992","display_name":"Dalian University of Technology","ror":"https://ror.org/023hj5876","country_code":"CN","type":"education","lineage":["https://openalex.org/I27357992"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shi Jing","raw_affiliation_strings":["School of Civil Engineering, Dalian University of Technology, Ganjingzi District, Dalian Liaoning Province 116024, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Civil Engineering, Dalian University of Technology, Ganjingzi District, Dalian Liaoning Province 116024, China","institution_ids":["https://openalex.org/I27357992"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Wang Hongbin","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I27357992","display_name":"Dalian University of Technology","ror":"https://ror.org/023hj5876","country_code":"CN","type":"education","lineage":["https://openalex.org/I27357992"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wang Hongbin","raw_affiliation_strings":["School of Civil Engineering, Dalian University of Technology, Ganjingzi District, Dalian Liaoning Province 116024, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Civil Engineering, Dalian University of Technology, Ganjingzi District, Dalian Liaoning Province 116024, China","institution_ids":["https://openalex.org/I27357992"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100521969","display_name":"Lin Duanmu","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I27357992","display_name":"Dalian University of Technology","ror":"https://ror.org/023hj5876","country_code":"CN","type":"education","lineage":["https://openalex.org/I27357992"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Duanmu Lin","raw_affiliation_strings":["School of Civil Engineering, Dalian University of Technology, Ganjingzi District, Dalian Liaoning Province 116024, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Civil Engineering, Dalian University of Technology, Ganjingzi District, Dalian Liaoning Province 116024, China","institution_ids":["https://openalex.org/I27357992"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5076459579","display_name":"Mingrui Zhu","orcid":"https://orcid.org/0000-0002-4179-7701","observed_orcids":["https://orcid.org/0000-0002-4179-7701"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Zhu Mingrui","raw_affiliation_strings":["Yingkou Weizi Air Conditioning Co., Dalian, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Yingkou Weizi Air Conditioning Co., Dalian, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I27357992"],"apc_list":null,"apc_paid":null,"fwci":1.1016,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.80377518,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":96},"biblio":{"volume":"23","issue":"3","first_page":"405","last_page":"412"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9717000126838684,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9717000126838684,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.010999999940395355,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":0.0027000000700354576,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/parallel-pipes","display_name":"parallel pipes","score":0.8560000061988831},{"id":"https://openalex.org/keywords/cooling-capacity","display_name":"cooling capacity","score":0.8240000009536743},{"id":"https://openalex.org/keywords/radiation-heat-exchange","display_name":"radiation heat exchange","score":0.7990000247955322},{"id":"https://openalex.org/keywords/convective-heat-transfer","display_name":"convective heat transfer","score":0.843999981880188},{"id":"https://openalex.org/keywords/heat-transfer-characteristics","display_name":"heat transfer characteristics","score":0.7229999899864197},{"id":"https://openalex.org/keywords/space-heating-and-cooling","display_name":"space heating and cooling","score":0.6790000200271606}],"concepts":[{"id":"https://openalex.org/C2777087718","wikidata":"https://www.wikidata.org/wiki/Q17155651","display_name":"Radiant cooling","level":2,"score":0.79435133934021},{"id":"https://openalex.org/C164915370","wikidata":"https://www.wikidata.org/wiki/Q5167494","display_name":"Cooling capacity","level":2,"score":0.6703385710716248},{"id":"https://openalex.org/C123516432","wikidata":"https://www.wikidata.org/wiki/Q572309","display_name":"Chilled water","level":3,"score":0.5880131125450134},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5181247591972351},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5082449316978455},{"id":"https://openalex.org/C2777489069","wikidata":"https://www.wikidata.org/wiki/Q1589822","display_name":"Ceiling (cloud)","level":2,"score":0.5082030296325684},{"id":"https://openalex.org/C2779664074","wikidata":"https://www.wikidata.org/wiki/Q3518405","display_name":"Terminal (telecommunication)","level":2,"score":0.5064619779586792},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.5038301348686218},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.4406537711620331},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.41025251150131226},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.3847283720970154},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.3477250635623932},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.3035019636154175},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.13516253232955933},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.09964552521705627},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1080/23744731.2017.1285174","doi":"https://doi.org/10.1080/23744731.2017.1285174","is_oa":false,"landing_page_url":"https://doi.org/10.1080/23744731.2017.1285174","pdf_url":null,"source":{"id":"https://openalex.org/S2764534234","display_name":"Science and Technology for the Built Environment","issn_l":"1078-9669","issn":["1078-9669","1938-5587","2374-4731","2374-474X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Science and Technology for the Built Environment","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.75}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W1966153144","https://openalex.org/W2054038519","https://openalex.org/W2067863919"],"related_works":["https://openalex.org/W2079391609","https://openalex.org/W3129412390","https://openalex.org/W2355634926","https://openalex.org/W7009695478","https://openalex.org/W4408303101","https://openalex.org/W2056131143","https://openalex.org/W3088259246","https://openalex.org/W4200268093","https://openalex.org/W4409670701","https://openalex.org/W2602236942"],"abstract_inverted_index":{"A":[0],"new":[1],"type":[2],"of":[3,33,52,56,71,86,93,98,130,145],"air-conditioning":[4,165],"terminal":[5,166,173],"device":[6,58,73,119,132,167],"that":[7,66,126],"could":[8],"be":[9],"used":[10],"both":[11],"for":[12],"cooling":[13,47,69,114,123,128,148,154],"in":[14,18,22],"summer":[15],"and":[16,42,44,49,61,88,120,168],"heating":[17],"winter":[19],"was":[20,39],"studied":[21],"the":[23,29,34,46,50,57,67,72,82,89,99,105,118,121,127,131,143,146,151,158,160],"research.":[24],"In":[25,157],"order":[26],"to":[27,104],"obtain":[28],"heat":[30,54,101,107],"transfer":[31],"characteristics":[32],"device,":[35],"a":[36],"test":[37],"rig":[38],"set":[40],"up":[41],"measured,":[43],"then":[45],"capacity":[48,70,115,129],"percentage":[51],"radiation":[53,100],"exchange":[55,102,108],"were":[59,175],"calculated":[60],"analyzed.":[62],"The":[63,96,113],"results":[64],"show":[65],"total":[68,106],"can":[74],"reach":[75],"631.0":[76],"W":[77],"(i.e.,":[78],"143.8":[79],"W/m2)":[80],"under":[81],"supply":[83],"water":[84,90],"temperature":[85],"8\u00b0C":[87],"flow":[91],"rate":[92,103,109],"240":[94],"L/h.":[95],"proportion":[97],"is":[110],"around":[111],"one-third.":[112],"comparison":[116],"between":[117,162],"radiant":[122,147],"ceiling":[124],"shows":[125],"increases":[133],"by":[134],"about":[135],"57.6%":[136],"per":[137],"square":[138],"meter":[139],"surface":[140],"area":[141],"over":[142],"value":[144],"ceilings":[149],"at":[150],"same":[152],"inlet":[153],"medium":[155],"temperature.":[156],"end,":[159],"differences":[161],"this":[163],"radiant\u2013convective":[164],"other":[169],"common":[170],"space":[171],"heating/cooling":[172],"devices":[174],"summerized.":[176]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":1}],"updated_date":"2026-08-15T07:11:24.734988","created_date":"2017-02-17T00:00:00"}
