{"id":"https://openalex.org/W2572026530","doi":"https://doi.org/10.1109/tdei.2016.006095","title":"Frequency spectrum investigation and analytical diagnosis method for turn-to-turn short-circuit insulation failure in stator winding of low voltage induction motor","display_name":"Frequency spectrum investigation and analytical diagnosis method for turn-to-turn short-circuit insulation failure in stator winding of low voltage induction motor","publication_year":2016,"publication_date":"2016-12-01","ids":{"openalex":"https://openalex.org/W2572026530","doi":"https://doi.org/10.1109/tdei.2016.006095","mag":"2572026530"},"language":"en","primary_location":{"id":"doi:10.1109/tdei.2016.006095","doi":"https://doi.org/10.1109/tdei.2016.006095","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tdei.2016.006095","pdf_url":null,"source":{"id":"https://openalex.org/S19003042","display_name":"IEEE Transactions on Dielectrics and Electrical Insulation","issn_l":"1070-9878","issn":["1070-9878","1558-4135"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Dielectrics and Electrical Insulation","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5067500709","display_name":"Shrinathan Esakimuthu Pandarakone","orcid":"https://orcid.org/0000-0003-1366-2639","observed_orcids":["https://orcid.org/0000-0003-1366-2639"]},"institutions":[{"id":"https://openalex.org/I197274945","display_name":"Nagoya Institute of Technology","ror":"https://ror.org/055yf1005","country_code":"JP","type":"education","lineage":["https://openalex.org/I197274945"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Shrinathan Esakimuthu Pandarakone","raw_affiliation_strings":["Nagoya Institute of Technology, Nagoya, JAPAN"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Nagoya Institute of Technology, Nagoya, JAPAN","institution_ids":["https://openalex.org/I197274945"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5013441371","display_name":"Yukio Mizuno","orcid":"https://orcid.org/0000-0002-2185-2187","observed_orcids":["https://orcid.org/0000-0002-2185-2187"]},"institutions":[{"id":"https://openalex.org/I197274945","display_name":"Nagoya Institute of Technology","ror":"https://ror.org/055yf1005","country_code":"JP","type":"education","lineage":["https://openalex.org/I197274945"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Yukio Mizuno","raw_affiliation_strings":["Nagoya Institute of Technology, Nagoya, JAPAN"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Nagoya Institute of Technology, Nagoya, JAPAN","institution_ids":["https://openalex.org/I197274945"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5070196529","display_name":"Hisahide Nakamura","orcid":"https://orcid.org/0000-0003-1356-1758","observed_orcids":["https://orcid.org/0000-0003-1356-1758"]},"institutions":[{"id":"https://openalex.org/I4405264313","display_name":"Toenec Corporation (Japan)","ror":"https://ror.org/01j90kz95","country_code":"JP","type":"company","lineage":["https://openalex.org/I4405264313"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Hisahide Nakamura","raw_affiliation_strings":["R&D Division, TOENEC Corporation, Nagoya, JAPAN"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"R&D Division, TOENEC Corporation, Nagoya, JAPAN","institution_ids":["https://openalex.org/I4405264313"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":1.851,"has_fulltext":false,"cited_by_count":21,"citation_normalized_percentile":{"value":0.84788274,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":"23","issue":"6","first_page":"3249","last_page":"3255"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9945999979972839,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9945999979972839,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.002400000113993883,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.0010000000474974513,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/turn-to-turn-short-circuit","display_name":"turn-to-turn short circuit","score":0.9279999732971191},{"id":"https://openalex.org/keywords/frequency-spectrum-analysis","display_name":"frequency spectrum analysis","score":0.8220000267028809},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"condition monitoring","score":0.5870000123977661},{"id":"https://openalex.org/keywords/support-vector-machine","display_name":"support vector machine","score":0.6510000228881836},{"id":"https://openalex.org/keywords/fault-diagnosis","display_name":"fault diagnosis","score":0.7559999823570251},{"id":"https://openalex.org/keywords/insulation-degradation","display_name":"insulation degradation","score":0.36399999260902405}],"concepts":[{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.8410201668739319},{"id":"https://openalex.org/C180591934","wikidata":"https://www.wikidata.org/wiki/Q1253369","display_name":"Downtime","level":2,"score":0.8365837335586548},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.6683017015457153},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5372998118400574},{"id":"https://openalex.org/C68583231","wikidata":"https://www.wikidata.org/wiki/Q206907","display_name":"Short circuit","level":3,"score":0.5056474208831787},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.45750948786735535},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.36237338185310364},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3294340968132019},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.31308966875076294}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tdei.2016.006095","doi":"https://doi.org/10.1109/tdei.2016.006095","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tdei.2016.006095","pdf_url":null,"source":{"id":"https://openalex.org/S19003042","display_name":"IEEE Transactions on Dielectrics and Electrical Insulation","issn_l":"1070-9878","issn":["1070-9878","1558-4135"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Dielectrics and Electrical Insulation","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6773999929428101,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1975660353","https://openalex.org/W2015396120","https://openalex.org/W2029959080","https://openalex.org/W2054700843","https://openalex.org/W2079376858","https://openalex.org/W2116135834","https://openalex.org/W2118623933","https://openalex.org/W2153452735","https://openalex.org/W2240365556","https://openalex.org/W2245037211","https://openalex.org/W2248417053","https://openalex.org/W2274618150","https://openalex.org/W2318939734","https://openalex.org/W2327893827","https://openalex.org/W3127912371","https://openalex.org/W4230505404","https://openalex.org/W4233898916","https://openalex.org/W4254945705"],"related_works":["https://openalex.org/W2245037211","https://openalex.org/W2899452468","https://openalex.org/W2312369169","https://openalex.org/W1847038316","https://openalex.org/W1605067682","https://openalex.org/W2031814031","https://openalex.org/W2141861347","https://openalex.org/W4323796271","https://openalex.org/W3034509793","https://openalex.org/W3021113674"],"abstract_inverted_index":{"Low-voltage":[0],"induction":[1,25],"motors":[2],"are":[3,10,93],"widely":[4],"used":[5],"in":[6,69],"the":[7,16,65,111,124,135,145,150,157],"factories":[8],"and":[9,21,101,116,152],"becoming":[11],"very":[12],"essential":[13],"components":[14,85],"for":[15],"industrial":[17],"process.":[18],"Improper":[19],"diagnosis":[20,147],"condition":[22],"monitoring":[23],"of":[24,50,59,64,82,86,98,113,126,137,159],"motor":[26,70],"not":[27],"only":[28],"leads":[29],"to":[30,41,54,122],"high":[31],"repair":[32],"expenses":[33],"but":[34],"also":[35],"cause":[36],"extraordinary":[37],"financial":[38],"losses":[39],"due":[40,53],"their":[42,55],"unexpected":[43],"downtime.":[44],"In":[45],"general,":[46],"turn-to-turn":[47,166],"short-circuit":[48,167],"failure":[49,163],"stator":[51],"winding":[52],"deterioration":[56],"or":[57],"damage":[58],"electrical":[60],"insulation":[61,162],"is":[62,132,142],"one":[63,165],"most":[66],"feasible":[67],"failures":[68],"drive":[71],"systems.":[72],"This":[73,108],"paper":[74],"proposes":[75],"a":[76,128,160],"diagnostic":[77,130],"method":[78,109,131,148],"based":[79],"on":[80,104],"amplitudes":[81],"characteristic":[83],"frequency":[84,99],"load":[87,105],"current":[88,106],"as":[89],"features.":[90],"These":[91],"features":[92,151],"extracted":[94],"by":[95],"close":[96],"analysis":[97],"spectrum":[100],"its":[102],"dependence":[103],"variation.":[107],"has":[110],"advantage":[112],"low":[114],"cost":[115],"short":[117],"data":[118],"processing":[119],"time.":[120],"Also":[121],"enhance":[123],"accuracy":[125],"diagnosis,":[127],"novel":[129],"proposed":[133,146],"with":[134,168],"aid":[136],"Support":[138,153],"Vector":[139,154],"Machine.":[140],"It":[141],"found":[143],"that":[144],"using":[149],"Machine":[155],"enables":[156],"detection":[158],"slight":[161],"like":[164],"practically":[169],"accepted":[170],"accuracy.":[171]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":2}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2017-01-26T00:00:00"}
