{"id":"https://openalex.org/W2557504686","doi":"https://doi.org/10.13182/nt16-89","title":"A Probabilistic Hazard Assessment Framework for Safety-Critical and Control Systems: A Case Study for a Nuclear Power Plant","display_name":"A Probabilistic Hazard Assessment Framework for Safety-Critical and Control Systems: A Case Study for a Nuclear Power Plant","publication_year":2016,"publication_date":"2016-12-03","ids":{"openalex":"https://openalex.org/W2557504686","doi":"https://doi.org/10.13182/nt16-89","mag":"2557504686"},"language":"en","primary_location":{"id":"doi:10.13182/nt16-89","doi":"https://doi.org/10.13182/nt16-89","is_oa":false,"landing_page_url":"https://doi.org/10.13182/nt16-89","pdf_url":null,"source":{"id":"https://openalex.org/S190997038","display_name":"Nuclear Technology","issn_l":"0029-5450","issn":["0029-5450","1943-7471"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-100","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Nuclear Technology","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5022530074","display_name":"Vinay Kumar","orcid":"https://orcid.org/0000-0001-8067-9727","observed_orcids":["https://orcid.org/0000-0001-8067-9727","https://orcid.org/0000-0002-7702-6968"]},"institutions":[{"id":"https://openalex.org/I56404289","display_name":"Indian Institute of Technology BHU","ror":"https://ror.org/01kh5gc44","country_code":"IN","type":"education","lineage":["https://openalex.org/I56404289","https://openalex.org/I91357014"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Vinay Kumar","raw_affiliation_strings":["Indian Institute of Technology (Banaras Hindu University), Department of Computer Science and Engineering, Varanasi, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology (Banaras Hindu University), Department of Computer Science and Engineering, Varanasi, India","institution_ids":["https://openalex.org/I56404289"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043500933","display_name":"Lalit Kumar Singh","orcid":"https://orcid.org/0000-0003-0375-3414","observed_orcids":["https://orcid.org/0000-0003-0375-3414"]},"institutions":[{"id":"https://openalex.org/I56404289","display_name":"Indian Institute of Technology BHU","ror":"https://ror.org/01kh5gc44","country_code":"IN","type":"education","lineage":["https://openalex.org/I56404289","https://openalex.org/I91357014"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Lalit Singh","raw_affiliation_strings":["Indian Institute of Technology (Banaras Hindu University), Department of Computer Science and Engineering, Varanasi, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology (Banaras Hindu University), Department of Computer Science and Engineering, Varanasi, India","institution_ids":["https://openalex.org/I56404289"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5102913253","display_name":"Amit Kumar Tripathi","orcid":"https://orcid.org/0009-0009-1972-9823","observed_orcids":["https://orcid.org/0009-0009-1972-9823"]},"institutions":[{"id":"https://openalex.org/I56404289","display_name":"Indian Institute of Technology BHU","ror":"https://ror.org/01kh5gc44","country_code":"IN","type":"education","lineage":["https://openalex.org/I56404289","https://openalex.org/I91357014"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"A. K. Tripathi","raw_affiliation_strings":["Indian Institute of Technology (Banaras Hindu University), Department of Computer Science and Engineering, Varanasi, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology (Banaras Hindu University), Department of Computer Science and Engineering, Varanasi, India","institution_ids":["https://openalex.org/I56404289"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5022530074"],"corresponding_institution_ids":["https://openalex.org/I56404289"],"apc_list":null,"apc_paid":null,"fwci":0.314,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.7280781,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":"197","issue":"1","first_page":"20","last_page":"28"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},"topics":[{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T13295","display_name":"Safety Systems Engineering in Autonomy","score":0.003599999938160181,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/probabilistic-hazard-assessment","display_name":"probabilistic hazard assessment","score":0.8970000147819519},{"id":"https://openalex.org/keywords/safety-critical-systems","display_name":"safety-critical systems","score":0.9879999756813049},{"id":"https://openalex.org/keywords/control-systems","display_name":"control systems","score":0.8730000257492065},{"id":"https://openalex.org/keywords/probabilistic-safety-assessment","display_name":"probabilistic safety assessment","score":0.8230000138282776},{"id":"https://openalex.org/keywords/hazard-quantification","display_name":"hazard quantification","score":0.7879999876022339},{"id":"https://openalex.org/keywords/nuclear-power-plants","display_name":"nuclear power plants","score":0.8399999737739563},{"id":"https://openalex.org/keywords/safety-assessment","display_name":"safety assessment","score":0.5979999899864197}],"concepts":[{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6867191791534424},{"id":"https://openalex.org/C49937458","wikidata":"https://www.wikidata.org/wiki/Q2599292","display_name":"Probabilistic logic","level":2,"score":0.6735219955444336},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.6642736196517944},{"id":"https://openalex.org/C132835097","wikidata":"https://www.wikidata.org/wiki/Q7663745","display_name":"System safety","level":2,"score":0.6564653515815735},{"id":"https://openalex.org/C73722673","wikidata":"https://www.wikidata.org/wiki/Q1082833","display_name":"Probabilistic risk assessment","level":3,"score":0.5981717109680176},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5930825471878052},{"id":"https://openalex.org/C2779979336","wikidata":"https://www.wikidata.org/wiki/Q134447","display_name":"Nuclear power plant","level":2,"score":0.5878994464874268},{"id":"https://openalex.org/C513653683","wikidata":"https://www.wikidata.org/wiki/Q12739","display_name":"Nuclear power","level":2,"score":0.5472663044929504},{"id":"https://openalex.org/C206355099","wikidata":"https://www.wikidata.org/wiki/Q3614972","display_name":"Hazard analysis","level":2,"score":0.5344283580780029},{"id":"https://openalex.org/C46136384","wikidata":"https://www.wikidata.org/wiki/Q351261","display_name":"Boiler feedwater","level":3,"score":0.5121407508850098},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.5037063956260681},{"id":"https://openalex.org/C12174686","wikidata":"https://www.wikidata.org/wiki/Q1058438","display_name":"Risk assessment","level":2,"score":0.49689915776252747},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.25666147470474243},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22499942779541016},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.15296542644500732},{"id":"https://openalex.org/C185544564","wikidata":"https://www.wikidata.org/wiki/Q81197","display_name":"Nuclear physics","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.13182/nt16-89","doi":"https://doi.org/10.13182/nt16-89","is_oa":false,"landing_page_url":"https://doi.org/10.13182/nt16-89","pdf_url":null,"source":{"id":"https://openalex.org/S190997038","display_name":"Nuclear Technology","issn_l":"0029-5450","issn":["0029-5450","1943-7471"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-100","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Nuclear Technology","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1494131797","https://openalex.org/W1520733518","https://openalex.org/W1979822432","https://openalex.org/W2059498196","https://openalex.org/W2079154298","https://openalex.org/W2248981713","https://openalex.org/W2272706637","https://openalex.org/W2279682188"],"related_works":["https://openalex.org/W3134136567","https://openalex.org/W2090885968","https://openalex.org/W3120712904","https://openalex.org/W2028541332","https://openalex.org/W4236565635","https://openalex.org/W1045182001","https://openalex.org/W2955196910","https://openalex.org/W7096677610","https://openalex.org/W2584575439","https://openalex.org/W3004984449"],"abstract_inverted_index":{"Any":[0],"risk":[1,24],"in":[2],"safety-critical":[3,82],"or":[4,59],"control":[5,86],"applications":[6],"may":[7],"lead":[8],"to":[9,31,54,60,77,93,112],"catastrophic":[10],"disaster;":[11],"hence,":[12],"safety":[13,41,80,91],"is":[14],"a":[15,40,56,73,128,147],"primary":[16],"concern":[17],"for":[18],"such":[19,144],"applications.":[20],"The":[21,102,132],"impact":[22],"of":[23,49,81,98,127,146],"varies":[25],"from":[26,65],"minor":[27],"inconvenience":[28],"and":[29,37,85,142],"cost":[30],"personal":[32],"injury,":[33],"significant":[34],"economic":[35],"loss,":[36],"death.":[38],"Therefore,":[39],"assessment":[42,92],"process":[43,53],"should":[44],"be":[45],"an":[46],"inherent":[47],"part":[48],"the":[50,63,79,96,99,119,122,136],"system":[51,57,126],"development":[52],"make":[55],"safe":[58],"ensure":[61],"that":[62,135],"effects":[64],"failures":[66],"are":[67],"minimized.":[68],"This":[69,116],"paper":[70,117],"deals":[71],"with":[72,95],"new":[74],"probabilistic":[75,90],"approach":[76],"quantify":[78,143],"systems":[83,87],"(SCSs)":[84],"based":[88],"on":[89,107,121],"deal":[94],"shortcomings":[97],"existing":[100],"techniques.":[101],"methodology":[103,120],"has":[104],"been":[105],"tested":[106],"29":[108],"operational":[109],"data":[110],"sets":[111],"validate":[113],"its":[114],"effectiveness.":[115],"demonstrates":[118],"digital":[123],"feedwater":[124],"controller":[125],"nuclear":[129],"power":[130],"plant.":[131],"results":[133],"indicate":[134],"method":[137],"can":[138],"identify":[139],"possible":[140],"hazards":[141,145],"SCS.":[148]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":1}],"updated_date":"2026-09-24T07:57:37.273135","created_date":"2016-12-08T00:00:00"}