{"id":"https://openalex.org/W2554479519","doi":"https://doi.org/10.1002/eej.22936","title":"PV Power Output Control Improving Transient Stability of Power System with a Large Penetration of PV","display_name":"PV Power Output Control Improving Transient Stability of Power System with a Large Penetration of PV","publication_year":2016,"publication_date":"2016-11-23","ids":{"openalex":"https://openalex.org/W2554479519","doi":"https://doi.org/10.1002/eej.22936","mag":"2554479519"},"language":"en","primary_location":{"id":"doi:10.1002/eej.22936","doi":"https://doi.org/10.1002/eej.22936","is_oa":false,"landing_page_url":"https://doi.org/10.1002/eej.22936","pdf_url":null,"source":{"id":"https://openalex.org/S167620381","display_name":"Electrical Engineering in Japan","issn_l":"0424-7760","issn":["0424-7760","1520-6416"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["dongbi-c","norway-1","poland-20","russia-white-list-4"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Electrical Engineering in Japan","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048132091","display_name":"Yasuaki Mitsugi","orcid":"https://orcid.org/0000-0003-0858-5958","observed_orcids":["https://orcid.org/0000-0003-0858-5958"]},"institutions":[{"id":"https://openalex.org/I74801974","display_name":"The University of Tokyo","ror":"https://ror.org/057zh3y96","country_code":"JP","type":"education","lineage":["https://openalex.org/I74801974"]}],"countries":["JP"],"is_corresponding":true,"raw_author_name":"YASUAKI MITSUGI","raw_affiliation_strings":["The University of Tokyo, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The University of Tokyo, Japan","institution_ids":["https://openalex.org/I74801974"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5083087969","display_name":"Akihiko Yokoyama","orcid":"https://orcid.org/0000-0003-1950-8966","observed_orcids":["https://orcid.org/0000-0003-1950-8966"]},"institutions":[{"id":"https://openalex.org/I74801974","display_name":"The University of Tokyo","ror":"https://ror.org/057zh3y96","country_code":"JP","type":"education","lineage":["https://openalex.org/I74801974"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"AKIHIKO YOKOYAMA","raw_affiliation_strings":["The University of Tokyo, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The University of Tokyo, Japan","institution_ids":["https://openalex.org/I74801974"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081164257","display_name":"Seiji Yamada","orcid":"https://orcid.org/0000-0002-5258-4488","observed_orcids":["https://orcid.org/0000-0002-5258-4488"]},"institutions":[{"id":"https://openalex.org/I2801034194","display_name":"Hokuriku Electric Power Company (Japan)","ror":"https://ror.org/00k98ea94","country_code":"JP","type":"company","lineage":["https://openalex.org/I2801034194"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"SEIJI YAMADA","raw_affiliation_strings":["Hokuriku Electric Power Company, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hokuriku Electric Power Company, Japan","institution_ids":["https://openalex.org/I2801034194"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5042055318","display_name":"Tomoya Tanikawa","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2801034194","display_name":"Hokuriku Electric Power Company (Japan)","ror":"https://ror.org/00k98ea94","country_code":"JP","type":"company","lineage":["https://openalex.org/I2801034194"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"TOMOYA TANIKAWA","raw_affiliation_strings":["Hokuriku Electric Power Company, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hokuriku Electric Power Company, Japan","institution_ids":["https://openalex.org/I2801034194"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5048132091"],"corresponding_institution_ids":["https://openalex.org/I74801974"],"apc_list":{"value":2630,"currency":"USD","value_usd":2630},"apc_paid":null,"fwci":0.1536,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.61682011,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"198","issue":"4","first_page":"15","last_page":"25"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.8949999809265137,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.8949999809265137,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.06080000102519989,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.02879999950528145,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transient-stability","display_name":"transient stability","score":0.984000027179718},{"id":"https://openalex.org/keywords/fault-ride-through","display_name":"fault ride-through","score":0.8970000147819519},{"id":"https://openalex.org/keywords/voltage-drop","display_name":"voltage drop","score":0.8130000233650208},{"id":"https://openalex.org/keywords/power-system-stability","display_name":"power system stability","score":0.6240000128746033},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"distributed generation","score":0.46700000762939453}],"concepts":[{"id":"https://openalex.org/C2780371621","wikidata":"https://www.wikidata.org/wiki/Q3709910","display_name":"Disconnection","level":2,"score":0.673577606678009},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.6510111093521118},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.6262143850326538},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.5774397253990173},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4997100830078125},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4886529743671417},{"id":"https://openalex.org/C82178898","wikidata":"https://www.wikidata.org/wiki/Q166839","display_name":"Voltage drop","level":3,"score":0.4292314648628235},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.4267972409725189},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4224085211753845},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.39093172550201416},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3741312623023987},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33261966705322266},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.32667386531829834},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.296095609664917},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.25149595737457275},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.06818830966949463},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C199539241","wikidata":"https://www.wikidata.org/wiki/Q7748","display_name":"Law","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.0},{"id":"https://openalex.org/C17744445","wikidata":"https://www.wikidata.org/wiki/Q36442","display_name":"Political science","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1002/eej.22936","doi":"https://doi.org/10.1002/eej.22936","is_oa":false,"landing_page_url":"https://doi.org/10.1002/eej.22936","pdf_url":null,"source":{"id":"https://openalex.org/S167620381","display_name":"Electrical Engineering in Japan","issn_l":"0424-7760","issn":["0424-7760","1520-6416"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["dongbi-c","norway-1","poland-20","russia-white-list-4"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Electrical Engineering in Japan","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9853000044822693,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"},{"score":0.8970999717712402,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1969901117","https://openalex.org/W2087458779","https://openalex.org/W2173506326","https://openalex.org/W2518969203"],"related_works":["https://openalex.org/W2762981813","https://openalex.org/W2334820371","https://openalex.org/W1973443572","https://openalex.org/W1977434869","https://openalex.org/W2334066242","https://openalex.org/W4386069258","https://openalex.org/W2515432675","https://openalex.org/W3012113919","https://openalex.org/W2779629624","https://openalex.org/W4210617674"],"abstract_inverted_index":{"SUMMARY":[0],"Because":[1],"of":[2,13,33,38,81,89],"energy":[3],"and":[4,93],"environmental":[5],"policies":[6],"in":[7,23,25],"the":[8,82,99],"last":[9],"decade,":[10],"a":[11,46,50,86],"lot":[12],"photovoltaic":[14],"(PV)":[15],"generations":[16],"have":[17],"been":[18],"installed":[19],"into":[20],"power":[21,54,74,83],"systems":[22],"Japan":[24],"recent":[26],"years.":[27],"In":[28,70],"this":[29,71],"situation,":[30],"it":[31],"is":[32,66,91,96],"great":[34],"concern":[35],"that":[36],"disconnection":[37],"PV":[39,73],"due":[40],"to":[41],"voltage":[42],"drop":[43],"caused":[44],"by":[45,98],"system":[47,55,84],"fault":[48],"has":[49],"critical":[51],"impact":[52],"on":[53],"stability.":[56],"To":[57],"avoid":[58],"its":[59,94],"disconnection,":[60],"Fault":[61],"Ride":[62],"Through":[63],"(FRT)":[64],"requirement":[65],"applied":[67],"for":[68],"PVs.":[69],"paper,":[72],"output":[75],"control":[76],"which":[77],"improves":[78],"transient":[79],"stability":[80],"with":[85],"huge":[87],"amount":[88],"PVs":[90],"proposed":[92],"effectiveness":[95],"confirmed":[97],"numerical":[100],"simulations.":[101]},"counts_by_year":[{"year":2018,"cited_by_count":1}],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2016-11-30T00:00:00"}
