{"id":"https://openalex.org/W2545868142","doi":"https://doi.org/10.1109/ultsym.2008.0256","title":"Double-beam diffraction-grating transducers for improved blood flow measurement","display_name":"Double-beam diffraction-grating transducers for improved blood flow measurement","publication_year":2008,"publication_date":"2008-11-01","ids":{"openalex":"https://openalex.org/W2545868142","doi":"https://doi.org/10.1109/ultsym.2008.0256","mag":"2545868142"},"language":"en","primary_location":{"id":"doi:10.1109/ultsym.2008.0256","doi":"https://doi.org/10.1109/ultsym.2008.0256","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ultsym.2008.0256","pdf_url":null,"source":{"id":"https://openalex.org/S4210177450","display_name":"Proceedings/Proceedings - IEEE Ultrasonics Symposium","issn_l":"1051-0117","issn":["1051-0117","1551-3025"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 IEEE Ultrasonics Symposium","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5089972270","display_name":"David H. R. Vilkomerson","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"David Vilkomerson","raw_affiliation_strings":["DVX Limited Liability Company, Princeton, NJ, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"DVX Limited Liability Company, Princeton, NJ, USA","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5089972270"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.36836267,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1064","last_page":"1067"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.33079999685287476,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.33079999685287476,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.29739999771118164,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10662","display_name":"Ultrasonics and Acoustic Wave Propagation","score":0.09549999982118607,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/blood-flow-measurement","display_name":"blood flow measurement","score":0.8289999961853027},{"id":"https://openalex.org/keywords/doppler-shift","display_name":"Doppler shift","score":0.8190000057220459},{"id":"https://openalex.org/keywords/blood-flow-velocity","display_name":"blood flow velocity","score":0.5759999752044678},{"id":"https://openalex.org/keywords/spatial-period","display_name":"spatial period","score":0.5929999947547913},{"id":"https://openalex.org/keywords/transducer-design","display_name":"transducer design","score":0.4650000035762787}],"concepts":[{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.7345022559165955},{"id":"https://openalex.org/C2777813233","wikidata":"https://www.wikidata.org/wiki/Q1527816","display_name":"Grating","level":2,"score":0.6141716241836548},{"id":"https://openalex.org/C207114421","wikidata":"https://www.wikidata.org/wiki/Q133900","display_name":"Diffraction","level":2,"score":0.6108291745185852},{"id":"https://openalex.org/C126753812","wikidata":"https://www.wikidata.org/wiki/Q653294","display_name":"Diffraction grating","level":3,"score":0.5662850737571716},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.43182986974716187},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.28997159004211426},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.25004875659942627}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ultsym.2008.0256","doi":"https://doi.org/10.1109/ultsym.2008.0256","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ultsym.2008.0256","pdf_url":null,"source":{"id":"https://openalex.org/S4210177450","display_name":"Proceedings/Proceedings - IEEE Ultrasonics Symposium","issn_l":"1051-0117","issn":["1051-0117","1551-3025"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 IEEE Ultrasonics Symposium","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":2,"referenced_works":["https://openalex.org/W2166104823","https://openalex.org/W2169850947"],"related_works":["https://openalex.org/W2107742828","https://openalex.org/W2537124219","https://openalex.org/W1979735047","https://openalex.org/W2143132645","https://openalex.org/W2086225432","https://openalex.org/W1839711436","https://openalex.org/W4235384586","https://openalex.org/W4238736916","https://openalex.org/W1982762402","https://openalex.org/W6981127541"],"abstract_inverted_index":{"Two":[0],"diffraction-grating":[1,56],"transducers":[2],"on":[3,20],"either":[4],"side":[5],"of":[6,23,33,39,54],"a":[7,11,24],"conventional":[8],"transducer":[9],"form":[10],"configuration":[12],"with":[13],"useful":[14],"properties:":[15],"when":[16],"placed":[17],"in":[18],"or":[19],"the":[21,27,31,34,37,46,51,55,60],"wall":[22],"blood":[25,28,69],"vessel,":[26,35],"velocity":[29,40],"along":[30],"axis":[32],"i.e.":[36],"component":[38],"that":[41],"produces":[42],"net":[43],"flow,":[44],"equals":[45],"Doppler":[47],"shift":[48],"multiplied":[49],"by":[50],"spatial":[52],"period":[53],"transducers,independentlyofthefrequencyused":[57],"to":[58,67],"drive":[59],"transducers.":[61],"That":[62],"and":[63,74],"other":[64],"properties":[65],"leading":[66],"better":[68],"flow":[70],"measurement":[71],"are":[72],"described":[73],"experimentally":[75],"validated.":[76]},"counts_by_year":[{"year":2016,"cited_by_count":1}],"updated_date":"2026-10-06T10:28:23.643775","created_date":"2016-11-04T00:00:00"}
