{"id":"https://openalex.org/W2537419760","doi":null,"title":"Fault detection in induction motors as a result of transient analysis","display_name":"Fault detection in induction motors as a result of transient analysis","publication_year":1989,"publication_date":"1989-09-13","ids":{"openalex":"https://openalex.org/W2537419760","mag":"2537419760"},"language":"en","primary_location":{"id":"mag:2537419760","doi":null,"is_oa":false,"landing_page_url":"https://ieeexplore.ieee.org/abstract/document/55387","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"International Electric Machines and Drives Conference","raw_type":null},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5108226209","display_name":"SC ELDER","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I522815984","display_name":"Robert Gordon University","ror":"https://ror.org/04f0qj703","country_code":"GB","type":"education","lineage":["https://openalex.org/I522815984"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"S. Elder","raw_affiliation_strings":["Robert Gordon's Inst. of Technol., Aberdeen, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Robert Gordon's Inst. of Technol., Aberdeen, UK","institution_ids":["https://openalex.org/I522815984"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108283822","display_name":"J.F. Watson","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I522815984","display_name":"Robert Gordon University","ror":"https://ror.org/04f0qj703","country_code":"GB","type":"education","lineage":["https://openalex.org/I522815984"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"J.F. Watson","raw_affiliation_strings":["Robert Gordon's Inst. of Technol., Aberdeen, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Robert Gordon's Inst. of Technol., Aberdeen, UK","institution_ids":["https://openalex.org/I522815984"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5081201440","display_name":"William T. Thomson","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I522815984","display_name":"Robert Gordon University","ror":"https://ror.org/04f0qj703","country_code":"GB","type":"education","lineage":["https://openalex.org/I522815984"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"William T. Thomson","raw_affiliation_strings":["Robert Gordon's Inst. of Technol., Aberdeen, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Robert Gordon's Inst. of Technol., Aberdeen, UK","institution_ids":["https://openalex.org/I522815984"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I522815984"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":34,"citation_normalized_percentile":{"value":0.3697535,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"182","last_page":"186"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9872999787330627,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9872999787330627,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.003100000089034438,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.0027000000700354576,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/induction-motor","display_name":"induction motor","score":0.6899999976158142},{"id":"https://openalex.org/keywords/fault-detection","display_name":"fault detection","score":0.9929999709129333},{"id":"https://openalex.org/keywords/starting-transient","display_name":"starting transient","score":0.675000011920929},{"id":"https://openalex.org/keywords/transient-analysis","display_name":"transient analysis","score":0.7009999752044678},{"id":"https://openalex.org/keywords/three-phase-motor","display_name":"three-phase motor","score":0.6579999923706055},{"id":"https://openalex.org/keywords/fault-identification","display_name":"fault identification","score":0.8349999785423279}],"concepts":[{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.8149111270904541},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.7709685564041138},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.7250533699989319},{"id":"https://openalex.org/C2989121073","wikidata":"https://www.wikidata.org/wiki/Q1309019","display_name":"Transient analysis","level":3,"score":0.6749744415283203},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5689269304275513},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5091823935508728},{"id":"https://openalex.org/C116834253","wikidata":"https://www.wikidata.org/wiki/Q2039217","display_name":"Identification (biology)","level":2,"score":0.5036308169364929},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.46710172295570374},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3603314459323883},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3451871871948242},{"id":"https://openalex.org/C85761212","wikidata":"https://www.wikidata.org/wiki/Q1974593","display_name":"Transient response","level":2,"score":0.3224155604839325},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.16033944487571716},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.14189261198043823},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.11034166812896729},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C59822182","wikidata":"https://www.wikidata.org/wiki/Q441","display_name":"Botany","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2537419760","doi":null,"is_oa":false,"landing_page_url":"https://ieeexplore.ieee.org/abstract/document/55387","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"International Electric Machines and Drives Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5378999710083008,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2099499479","https://openalex.org/W824273145","https://openalex.org/W2133775483","https://openalex.org/W2769021756","https://openalex.org/W2484323358","https://openalex.org/W2805252169","https://openalex.org/W1611737674","https://openalex.org/W2161409289","https://openalex.org/W2185292425","https://openalex.org/W2334956596"],"abstract_inverted_index":{"A":[0],"technique":[1],"is":[2,31,44],"being":[3],"developed":[4],"which":[5],"will":[6,56],"allow":[7],"the":[8,20,37],"detection":[9],"and":[10,28],"identification":[11],"of":[12,39],"specific":[13],"faults":[14,35],"within":[15],"3-phase":[16],"induction":[17],"motors":[18],"during":[19],"starting":[21],"transient.":[22],"At":[23],"present":[24],"a":[25,40,61],"very":[26],"detailed":[27],"complex":[29],"analysis":[30,55],"used":[32],"to":[33,65],"detect":[34],"requiring":[36],"use":[38],"mainframe":[41],"computer.":[42],"It":[43],"anticipated":[45],"that":[46],"once":[47],"sufficient":[48],"test":[49],"data":[50],"has":[51],"been":[52],"obtained":[53],"this":[54],"be":[57,66],"dramatically":[58],"reduced,":[59],"allowing":[60],"stand":[62],"alone":[63],"instrument":[64],"designed.":[67]},"counts_by_year":[{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":4},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":6},{"year":2012,"cited_by_count":2}],"updated_date":"2026-10-27T15:51:10.671819","created_date":"2016-10-28T00:00:00"}
