{"id":"https://openalex.org/W2523200375","doi":null,"title":"Condition monitoring and optimization of a 340 MW re-powered combined cycle plant. Part 1: Design","display_name":"Condition monitoring and optimization of a 340 MW re-powered combined cycle plant. Part 1: Design","alternate_titles":[],"publication_year":1994,"publication_date":"1994-12-31","ids":{"openalex":"https://openalex.org/W2523200375","mag":"2523200375"},"language":"en","primary_location":{"id":"mag:2523200375","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/82759-condition-monitoring-optimization-mw-re-powered-combined-cycle-plant-part-design","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2523200375"],"child_works_count":0,"pull_notice_works":[],"type":"conference-paper","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101913603","display_name":"M. P. Boyce","type":null,"orcid":"https://orcid.org/0000-0002-2476-422X","observed_orcids":["https://orcid.org/0000-0002-2476-422X"]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"M. P. Boyce","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007446633","display_name":"Arkalgud N. Lakshminarasimha","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"A. N. Lakshminarasimha","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5012652574","display_name":"Hatim M. Motiwala","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Hatim M. Motiwala","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.33640000224113464,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.33640000224113464,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13856","display_name":"Advanced Power Generation Technologies","score":0.288100004196167,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.1445000022649765,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"condition monitoring","score":0.9879999756813049},{"id":"https://openalex.org/keywords/combined-cycle-power-plant","display_name":"combined cycle power plant","score":0.9319999814033508},{"id":"https://openalex.org/keywords/repowering","display_name":"repowering","score":0.8479999899864197},{"id":"https://openalex.org/keywords/gas-turbines","display_name":"gas turbines","score":0.7929999828338623},{"id":"https://openalex.org/keywords/steam-turbine-design","display_name":"steam turbine design","score":0.7080000042915344},{"id":"https://openalex.org/keywords/boiler-design","display_name":"boiler design","score":0.953000009059906},{"id":"https://openalex.org/keywords/plant-availability","display_name":"plant availability","score":0.7509999871253967},{"id":"https://openalex.org/keywords/operational-efficiency","display_name":"operational efficiency","score":0.9269999861717224}],"concepts":[{"id":"https://openalex.org/C110910425","wikidata":"https://www.wikidata.org/wiki/Q900729","display_name":"Combined cycle","level":3,"score":0.7190675735473633},{"id":"https://openalex.org/C4311470","wikidata":"https://www.wikidata.org/wiki/Q159719","display_name":"Power station","level":2,"score":0.70367431640625},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.6046072840690613},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.5799195170402527},{"id":"https://openalex.org/C14794904","wikidata":"https://www.wikidata.org/wiki/Q189859","display_name":"Steam turbine","level":2,"score":0.5136539340019226},{"id":"https://openalex.org/C2780013297","wikidata":"https://www.wikidata.org/wiki/Q19596153","display_name":"Boiler (water heating)","level":2,"score":0.48803749680519104},{"id":"https://openalex.org/C2987684023","wikidata":"https://www.wikidata.org/wiki/Q193470","display_name":"Gas turbines","level":2,"score":0.46385809779167175},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.44933223724365234},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.41877397894859314},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.4115581810474396},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4067174792289734},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3304608464241028},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.1949794590473175},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.15570229291915894},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09625434875488281}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2523200375","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/82759-condition-monitoring-optimization-mw-re-powered-combined-cycle-plant-part-design","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8970999717712402,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"},{"score":0.75,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2284568103","https://openalex.org/W2410605418","https://openalex.org/W2548480710","https://openalex.org/W2089929845","https://openalex.org/W581291864","https://openalex.org/W2090470222","https://openalex.org/W1584080039","https://openalex.org/W3208063348","https://openalex.org/W2315807210","https://openalex.org/W2356438163"],"abstract_inverted_index":{"This":[0],"paper":[1],"focuses":[2],"on":[3],"the":[4,33,36,45,63,93,96,103,107],"application":[5],"and":[6,15,41,47,73,100],"features":[7,130],"of":[8,32,38,65,68,95,102,106,113],"a":[9,21,114,120,139],"unified":[10],"multi-machine":[11,86],"train":[12],"condition":[13,97,115],"monitoring":[14,98,116],"diagnostic":[16],"system":[17,99,117,128,134],"as":[18],"applied":[19],"to":[20,44,56,61,81,119],"340":[22],"MW":[23],"repowered":[24],"combined":[25,121,140],"cycle":[26,122,141],"power":[27,108],"plant.":[28],"Modifications":[29],"during":[30,52],"repowering":[31],"plant":[34,70,109,123,142],"required":[35],"addition":[37],"gas":[39],"turbines,":[40],"design":[42,104,129],"changes":[43],"boiler":[46],"steam":[48],"turbine.":[49],"Operational":[50],"procedure":[51],"startup":[53],"also":[54,125],"had":[55],"be":[57],"developed.":[58],"In":[59,90],"order":[60],"improve":[62],"economics":[64],"operation,":[66],"enhancement":[67],"both":[69],"operational":[71],"efficiency":[72],"availability":[74],"were":[75],"required.":[76],"Thus":[77],"it":[78],"was":[79],"decided":[80],"implement":[82],"an":[83],"on-line":[84],"plant-wide":[85],"Condition":[87],"Monitoring":[88],"System.":[89],"this":[91],"paper,":[92],"details":[94,105],"some":[101],"are":[110,124,131],"presented.":[111],"Requirements":[112],"applicable":[118],"covered.":[126],"Salient":[127],"explained.":[132],"The":[133,145],"has":[135],"been":[136],"implemented":[137],"in":[138],"at":[143],"Bergum,":[144],"Netherlands.":[146]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2523200375","counts_by_year":[],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-09-30T00:00:00"}